Biomedical Engineering - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 12
  • Item
    No Preview Available
    Kinematics of the jaw following total temporomandibular joint replacement surgery.
    Woodford, SC ; Robinson, DL ; Abduo, J ; Lee, PVS ; Ackland, DC (Elsevier, 2023-10-01)
    Total temporomandibular joint (TMJ) replacement surgery aims to improve mandibular function, reduce pain and enhance quality of life in patients suffering from end-stage TMJ disorders. Traditional post-operative jaw evaluation is carried out using measurement of maximum interincisal opening distance; however, this can correlate poorly to joint function. The present study aimed to evaluate three-dimensional (3D) jaw motion during border movements and chewing in unilateral total TMJ replacement patients and healthy controls. Motion analysis experiments were performed on six unilateral total TMJ replacement patients and ten age-matched healthy controls. Subject-specific motion tracking plates worn by each participant were registered to CT scans of each participant's skull and mandible to enable anatomical mandibular kinematics measurement using an optoelectronic system. Participants performed 15 repetitions of maximal opening, protrusion, lateral excursions, and chewing cycles. Total TMJ replacement patients had significantly smaller incisal displacements at maximum mouth opening relative to the controls (median difference: 7.1 mm, p = 0.002) and decreased anterior translation of the prosthetic condyle (median difference: 10.5 mm, p = 0.002). When TMJ replacement subjects chewed using their contralateral molars, there was a significant increase in inferior condylar translation of the non-working condyle (median difference: 9.7 mm, p = 0.016). This study found that unilateral total TMJ replacement surgery was associated with mouth opening capacity within the range of healthy individuals, but reduced anterior movement of the prosthetic condyle and restricted protrusion and lateral excursions. The results provide future direction for prosthetic TMJ design to enhance postsurgical implant functionality and improve long-term clinical outcomes for prosthesis recipients.
  • Item
    Thumbnail Image
    Additively manufactured controlled porous orthopedic joint replacement designs to reduce bone stress shielding: a systematic review
    Safavi, S ; Yu, Y ; Robinson, DL ; Gray, HA ; Ackland, DC ; Lee, PVS (BMC, 2023-01-16)
    BACKGROUND: Total joint replacements are an established treatment for patients suffering from reduced mobility and pain due to severe joint damage. Aseptic loosening due to stress shielding is currently one of the main reasons for revision surgery. As this phenomenon is related to a mismatch in mechanical properties between implant and bone, stiffness reduction of implants has been of major interest in new implant designs. Facilitated by modern additive manufacturing technologies, the introduction of porosity into implant materials has been shown to enable significant stiffness reduction; however, whether these devices mitigate stress-shielding associated complications or device failure remains poorly understood. METHODS: In this systematic review, a broad literature search was conducted in six databases (Scopus, Web of Science, Medline, Embase, Compendex, and Inspec) aiming to identify current design approaches to target stress shielding through controlled porous structures. The search keywords included 'lattice,' 'implant,' 'additive manufacturing,' and 'stress shielding.' RESULTS: After the screening of 2530 articles, a total of 46 studies were included in this review. Studies focusing on hip, knee, and shoulder replacements were found. Three porous design strategies were identified, specifically uniform, graded, and optimized designs. The latter included personalized design approaches targeting stress shielding based on patient-specific data. All studies reported a reduction of stress shielding achieved by the presented design. CONCLUSION: Not all studies used quantitative measures to describe the improvements, and the main stress shielding measures chosen varied between studies. However, due to the nature of the optimization approaches, optimized designs were found to be the most promising. Besides the stiffness reduction, other factors such as mechanical strength can be considered in the design on a patient-specific level. While it was found that controlled porous designs are overall promising to reduce stress shielding, further research and clinical evidence are needed to determine the most superior design approach for total joint replacement implants.
  • Item
    No Preview Available
    Low-Profile Electromagnetic Field Sensors in the Measurement and Modelling of Three-Dimensional Jaw Kinematics and Occlusal Loading
    Woodford, SC ; Robinson, DL ; Edelmann, C ; Mehl, A ; Roehrle, O ; Vee Sin Lee, P ; Ackland, DC (SPRINGER, 2021-06)
    Dynamic occlusal loading during mastication is clinically relevant in the design and functional assessment of dental restorations and removable dentures, and in evaluating temporomandibular joint dysfunction. The aim of this study was to develop a modelling framework to evaluate subject-specific dynamic occlusal loading during chewing and biting over the entire dental arch. Measurements of jaw motion were performed on one healthy male adult using low-profile electromagnetic field sensors attached to the teeth, and occlusal anatomy quantified using an intra-oral scanner. During testing, the subject chewed and maximally compressed a piece of rubber between both second molars, first molars, premolars and their central incisors. The occlusal anatomy, rubber geometry and experimentally measured rubber material properties were combined in a finite element model. The measured mandibular motion was used to kinematically drive model simulations of chewing and biting of the rubber sample. Three-dimensional dynamic bite forces and contact pressures across the occlusal surfaces were then calculated. Both chewing and biting on the first molars produced the highest bite forces across the dental arch, and a large amount of anterior shear force was produced at the incisors and the second molars. During chewing, the initial tooth-rubber contact evolved from the buccal sides of the molars to the lingual sides at full mouth closure. Low-profile electromagnetic field sensors were shown to provide a clinically relevant measure of jaw kinematics with sufficient accuracy to drive finite element models of occlusal loading during chewing and biting. The modelling framework presented provides a basis for calculation of physiological, dynamic occlusal loading across the dental arch.
  • Item
    Thumbnail Image
    Influence of the geometric and material properties of lumbar endplate on lumbar interbody fusion failure: a systematic review
    Yu, Y ; Robinson, DL ; Ackland, DC ; Yang, Y ; Lee, PVS (BMC, 2022-04-10)
    BACKGROUND: Lumbar interbody fusion (LIF) is an established surgical intervention for patients with leg and back pain secondary to disc herniation or degeneration. Interbody fusion involves removal of the herniated or degenerated disc and insertion of interbody devices with bone grafts into the remaining cavity. Extensive research has been conducted on operative complications such as a failure of fusion or non-union of the vertebral bodies. Multiple factors including surgical, implant, and patient factors influencing the rate of complications have been identified. Patient factors include age, sex, osteoporosis, and patient anatomy. Complications can also be influenced by the interbody cage design. The geometry of the bony endplates as well as their corresponding material properties guides the design of interbody cages, which vary considerably across patients with spinal disorders. However, studies on the effects of such variations on the rate of complications are limited. Therefore, this study aimed to perform a systematic review of lumbar endplate geometry and material property factors in LIF failure. METHODS: Search keywords included 'factor/cause for spinal fusion failure/cage subsidence/cage migration/non-union', 'lumbar', and 'interbody' in electronic databases PubMed and Scopus with no limits on year of publication. RESULTS: In total, 1341 articles were reviewed, and 29 articles were deemed suitable for inclusion. Adverse events after LIF, such as cage subsidence, cage migration, and non-union, resulted in fusion failure; hence, risk factors for adverse events after LIF, notably those associated with lumbar endplate geometry and material properties, were also associated with fusion failure. Those risk factors were associated with shape, concavity, bone mineral density and stiffness of endplate, segmental disc angle, and intervertebral disc height. CONCLUSIONS: This review demonstrated that decreased contact areas between the cage and endplate, thin and weak bony endplate as well as spinal diseases such as spondylolisthesis and osteoporosis are important causes of adverse events after LIF. These findings will facilitate the selection and design of LIF cages, including customised implants based on patient endplate properties.
  • Item
    Thumbnail Image
    Complications of Reverse Total Shoulder Arthroplasty: A Computational Modelling Perspective
    Huang, Y ; Ernstbrunner, L ; Robinson, DL ; Lee, PVS ; Ackland, DC (MDPI, 2021-11)
    Reverse total shoulder arthroplasty (RTSA) is an established treatment for elderly patients with irreparable rotator cuff tears, complex proximal humerus fractures, and revision arthroplasty; however, with the increasing indications for RTSA over the last decade and younger implant recipients, post-operative complications have become more frequent, which has driven advances in computational modeling and simulation of reverse shoulder biomechanics. The objective of this study was to provide a review of previously published studies that employed computational modeling to investigate complications associated with RTSA. Models and applications were reviewed and categorized into four possible complications that included scapular notching, component loosening, glenohumeral joint instability, and acromial and scapular spine fracture, all of which remain a common cause of significant functional impairment and revision surgery. The computational shoulder modeling studies reviewed were primarily used to investigate the effects of implant design, intraoperative component placement, and surgical technique on postoperative shoulder biomechanics after RTSA, with the findings ultimately used to elucidate and mitigate complications. The most significant challenge associated with the development of computational models is in the encapsulation of patient-specific anatomy and surgical planning. The findings of this review provide a basis for future direction in computational modeling of the reverse shoulder.
  • Item
    No Preview Available
    Measurement of normal and pathological mandibular and temporomandibular joint kinematics: A systematic review.
    Woodford, SC ; Robinson, DL ; Mehl, A ; Lee, PVS ; Ackland, DC (Elsevier, 2020-10-09)
    Motion of the mandible and temporomandibular joint (TMJ) plays a pivotal role in the function of the dentition and associated hard and soft tissue structures, and facilitates mastication, oral communication and access to respiratory and digestive systems. Quantification of TMJ kinematics is clinically relevant in cases of prosthetic rehabilitations, TMJ disorders, osteoarthritis, trauma, tumour resection and congenital abnormalities, which are known to directly influence mandibular motion and loading. The objective of this systematic review was to critically investigate published literature on historic and contemporary measurement modalities used to quantify in vivo mandibular and TMJ kinematics in six degrees of freedom. The electronic databases of Scopus, Web of Science, Medline, Embase and Central were searched and 109 relevant articles identified. Publication quality was documented using a modified Downs and Black checklist. Axiography and ultrasonic tracking are commonly employed in the clinical setting due to their simplicity and capacity to rapidly acquire low-fidelity mandibular motion data. Magnetic and optoelectronic tracking have been used in combination with dental splints to produce higher accuracy measurements while minimising skin motion artefact, but at the expense of setup time and cost. Four-dimensional computed tomography provides direct 3D measurement of mandibular and TMJ motion while circumventing skin motion artefact entirely, but employs ionising radiation, is restricted to low sampling frequencies, and requires time-consuming image processing. Recent advances in magnetic tracking using miniature sensors adhered to the teeth in combination with intraoral scanning may facilitate rapid and high precision mandibular kinematics measurement in the clinical setting. The findings of this review will guide selection and application of mandibular and TMJ kinematic measurement for both clinical and research applications.
  • Item
    Thumbnail Image
    The influence of rotator cuff tears on muscle and joint-contact loading after reverse total shoulder arthroplasty
    Ackland, DC ; Robinson, DL ; Wilkosz, A ; Wu, W ; Richardson, M ; Lee, P ; Tse, KM (WILEY, 2019-01)
  • Item
    Thumbnail Image
    Mechanical properties of normal and osteoarthritic human articular cartilage
    Robinson, DL ; Kersh, ME ; Walsh, NC ; Ackland, DC ; de Steiger, RN ; Pandy, MG (ELSEVIER, 2016-08)
    Isotropic hyperelastic models have been used to determine the material properties of normal human cartilage, but there remains an incomplete understanding of how these properties may be altered by osteoarthritis. The aims of this study were to (1) measure the material constants of normal and osteoarthritic human knee cartilage using isotropic hyperelastic models; (2) determine whether the material constants correlate with histological measures of structure and/or cartilage tissue damage; and (3) quantify the abilities of two common isotropic hyperelastic material models, the neo-Hookean and Yeoh models, to describe articular cartilage contact force, area, and pressure. Small osteochondral specimens of normal and osteoarthritic condition were retrieved from human cadaveric knees and from the knees of patients undergoing total knee arthroplasty and tested in unconfined compression at loading rates and large strains representative of weight-bearing activity. Articular surface contact area and lateral deformation were measured concurrently and specimen-specific finite element models then were used to determine the hyperelastic material constants. Structural parameters were measured using histological techniques while the severity of cartilage damage was quantified using the OARSI grading scale. The hyperelastic material constants correlated significantly with OARSI grade, indicating that the mechanical properties of cartilage for large strains change with tissue damage. The measurements of contact area described anisotropy of the tissue constituting the superficial zone. The Yeoh model described contact force and pressure more accurately than the neo-Hookean model, whereas both models under-predicted contact area and poorly described the anisotropy of cartilage within the superficial zone. These results identify the limits by which isotropic hyperelastic material models may be used to describe cartilage contact variables. This study provides novel data for the mechanical properties of normal and osteoarthritic human articular cartilage and enhances our ability to model this tissue using simple isotropic hyperelastic materials.
  • Item
    Thumbnail Image
    Load response of the natural tooth and dental implant: A comparative biomechanics study
    Robinson, D ; Aguilar, L ; Gatti, A ; Abduo, J ; Lee, PVS ; Ackland, D (The Korean Academy of Prosthodontics, 2019-06-26)
    While dental implants have displayed high success rates, poor mechanical fixation is a common complication, and their biomechanical response to occlusal loading remains poorly understood. This study aimed to develop and validate a computational model of a natural first premolar and a dental implant with matching crown morphology, and quantify their mechanical response to loading at the occlusal surface. A finite-element model of the stomatognathic system comprising the mandible, first premolar and periodontal ligament (PDL) was developed based on a natural human tooth, and a model of a dental implant of identical occlusal geometry was also created. Occlusal loading was simulated using point forces applied at seven landmarks on each crown. Model predictions were validated using strain gauge measurements acquired during loading of matched physical models of the tooth and implant assemblies. For the natural tooth, the maximum vonMises stress (6.4 MPa) and maximal principal strains at the mandible (1.8 mε, −1.7 mε) were lower than those observed at the prosthetic tooth (12.5 MPa, 3.2 mε, and −4.4 mε, respectively). As occlusal load was applied more bucally relative to the tooth central axis, stress and strain magnitudes increased. Occlusal loading of the natural tooth results in lower stress-strain magnitudes in the underlying alveolar bone than those associated with a dental implant of matched occlusal anatomy. The PDL may function to mitigate axial and bending stress intensities resulting from off-centered occlusal loads. The findings may be useful in dental implant design, restoration material selection, and surgical planning.
  • Item
    Thumbnail Image
    Load response of an osseointegrated implant used in the treatment of unilateral transfemoral amputation: An early implant loosening case study.
    Robinson, DL ; Safai, L ; Harandi, VJ ; Graf, M ; Lizama, LEC ; Lee, P ; Galea, MP ; Khan, F ; Tse, KM ; Ackland, DC (Elsevier, 2020-03)
    BACKGROUND: Osseointegrated implants for transfemoral amputees facilitate direct load transfer between the prosthetic limb and femur; however, implant loosening is a common complication, and the associated implant-bone loads remain poorly understood. This case study aimed to use patient-specific computational modeling to evaluate bone-implant interface loading during standing and walking in a transfemoral amputee with an osseointegrated implant prior to prosthesis loosening and revision surgery. METHODS: One male transfemoral amputee with an osseointegrated implant was recruited (age: 59-yrs, weight: 83 kg) and computed tomography (CT) performed on the residual limb approximately 3 months prior to implant failure. Gait analyses were performed, and the CT images used to develop a finite element model of the patient's implant and surrounding bone. Simulations of static weight bearing, and over-ground walking were then performed. FINDINGS: During standing, maximum and minimum principal strains in trabecular bone adjacent to the implant were 0.26% and -0.30%, respectively. Strains generated at the instant of contralateral toe-off and contralateral heel strike during walking were substantially higher and resulted in local trabecular bone yielding. Specifically, the maximum and minimum principal strains in the thin layer of trabecular bone surrounding the distal end of the implant were 1.15% and -0.98%, respectively. INTERPRETATION: Localised yielding of trabecular bone at the interface between the femur and implant in transfemoral amputee osseointegrated prosthesis recipients may present a risk of implant loosening due to periprosthetic bone fracture during walking. Rehabilitation exercises should aim to produce implant-bone loading that stimulates bone remodelling to provide effective bone conditioning prior to ambulation.