- Architecture, Building and Planning - Research Publications
Architecture, Building and Planning - Research Publications
Permanent URI for this collection
5 results
Filters
Reset filtersSettings
Statistics
Citations
Search Results
Now showing
1 - 5 of 5
-
ItemPhysical and perceptual gap in indoor environmental quality: a mixed method study of space and users at an aged care facility in VictoriaNoguchi, M ; Woo, CMM ; Chau, H-W ; Zhou, J ; Pianella, A ; Newton, C (Taylor & Francis, 2019-05-11)Nearly a quarter of a million of Australia's ageing population live in residential aged care facilities. Given the growing ageing population in Australia, it is important to understand the indoor environmental quality (IEQ) of these settings in consideration of not only measurable IEQ data but also senior occupants’ perceived comfort for their health and wellbeing. In this research, a residential aged care facility was selected in Victoria, Australia, as a case study to examine these relationships across different seasons. IEQ monitoring devices were deployed for continuous and instantaneous data collection on site. Questionnaires and personal interviews were also conducted across three user groups (residents, staff and visitors) to establish an understanding of the users’ perceptions. This study found the existence of a gap between measurable and perceptual IEQ according to the building configuration and occupancy as well as the user lifestyle and activity.
-
ItemNo Preview AvailableA pilot study on users’ IEQ perceptions in a residential aged care facility in MelbourneChau, H ; Aye, L ; Noguchi, M ; Newton, C ; Zhou, J ; Mei Min Woo, C ; Rajagopalan, P ; Andamon, M (RMIT, 2018-11-29)The aged population in Australia is expanding rapidly. To cater for the Australia’s ageing population, there is a significant increase in demand for aged care facilities over the coming decades. The indoor environmental quality (IEQ) affects users’ physical health and psychological wellbeing. However, systematic research on the relationship between users’ perceptions and IEQ of aged care facilities has yet to be developed. In this pilot study, a residential aged care facility in Melbourne was selected as a case study for investigating the differences between the measured IEQ data and the users’ perceived individual comfort. A questionnaire survey was conducted to collect the perceptions of users on IEQ. Environmental sensors which enable web-based data monitoring were deployed. The measured data were then analysed together with the questionnaire survey results for drawing a comparison with the users’ perceptions. It was found that the measurements by environmental sensors are realistic and the survey questionnaires are appropriate for the study. For the future surveys, the language barrier needs to be considered for non-English speakers.
-
ItemNo Preview AvailableStructuring the Environmental Experience Design Research Framework through Selected Aged Care Facility Data Analyses in VictoriaMa, N ; Chau, H-W ; Zhou, J ; Noguchi, M (MDPI, 2017-12)
-
ItemComparing mixing ventilation and displacement ventilation in university classroomsZhou, J ; Chau, H-W ; Kang, Y ; Hes, D ; Noguchi, M ; Aye, L (ZEMCH Network, 2018-01-29)There are two main types of mechanical ventilation systems: the mixing ventilation (MV) and the displacement ventilation (DV). The aim of this work is to compare their performance in terms of ventilation efficiency, air temperature, relative humidity, size-resolved particle concentrations, carbon dioxide (CO2) concentrations, and energy consumption. We performed a field investigation in two side-by-side classrooms installed with the two different ventilation systems. The energy consumptions were measured by i) a heat meter to measure the energy extracted by chilled water supplied, and ii) a power analyser to measure energy consumed by the ventilation fan. We also monitor indoor air dry bulb temperature, relative humidity, and CO2 concentrations in real-time for both rooms. It was found that the classroom with DV system consumed more energy. The unexpected high energy consumption can be attributable to the improved ventilation, CO2 and humidity control in DV room. Air temperature stratification were observed in DV room, but both room achieved similar volume-averaged temperate. We also found lower particle concentrations in both rooms compared to outdoor levels.
-
ItemPilot study on IEQ of an aged-care facility in VictoriaChau, H-W ; Zhou, J ; Noguchi, M ; Hes, D ; Aye, L (ZEMCH Network, 2018-01-29)Australian population is ageing. The proportion of Australian population over 65 years old has been increased and it is projected to be 25% in 2042. Although the Victorian Government has promoted ageing in place under home care package services, there is still a genuine need to provide more residential aged care services to satisfy the needs. The indoor environmental quality (IEQ) of residential aged care facilities is closely related to the health and well-being of residents living there. In this pilot study, the Adare Supported Residential Services (SRS) in Victoria is selected as the site for investigation. Some sensors are deployed in both communal areas and residents’ rooms to collect transient data on IEQ parameters, including carbon dioxide concentration, dry bulb temperature, radiant temperature, relative humidity and illumination level. Data collected is analysed and the links between outdoor environmental conditions and IEQ parameters are investigated. Limitations of this pilot study are discussed and recommendations for the full study are provided.