Obstetrics and Gynaecology - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 56
  • Item
    No Preview Available
    Apnoeic oxygenation during neonatal intubation
    Baker, EK ; Davis, PG ; Hodgson, KA (ELSEVIER SCI LTD, 2023-10)
    'Apnoeic oxygenation' describes the diffusion of oxygen across the alveolar-capillary interface in the absence of tidal respiration. Apnoeic oxygenation requires a patent airway, the diffusion of oxygen to the alveoli, and cardiopulmonary circulation. Apnoeic oxygenation has varied applications in adult medicine including facilitating tubeless anaesthesia or improving oxygenation when a difficult airway is known or anticipated. In the paediatric population, apnoeic oxygenation prolongs the time to oxygen desaturation, facilitating intubation. This application has gained attention in neonatal intensive care where intubation remains a challenging procedure. Difficulties are related to the infant's size and decreased respiratory reserve. In addition, policy changes have led to limited opportunities for operators to gain proficiency. Until recently, evidence of benefit of apnoeic oxygenation in the neonatal population came from a small number of infants recruited to paediatric studies. Evidence specific to neonates is emerging and suggests apnoeic oxygenation may increase intubation success and limit physiological instability during the procedure. The best way to deliver oxygen to facilitate apnoeic oxygenation remains an important question.
  • Item
    No Preview Available
    Introduction to neonatal intubation and extubation
    Hodgson, KA ; Davis, PG (ELSEVIER SCI LTD, 2023-10)
  • Item
    No Preview Available
    Higher versus lower nasal continuous positive airway pressure for extubation of extremely preterm infants in Australia (ÉCLAT): a multicentre, randomised, superiority trial
    Kidman, AM ; Manley, BJ ; Boland, RA ; Malhotra, A ; Donath, SM ; Beker, F ; Davis, PG ; Bhatia, R (Elsevier, 2023-12)
    BACKGROUND: Extremely preterm infants often require invasive mechanical ventilation, and clinicians aim to extubate these infants as soon as possible. However, extubation failure occurs in up to 60% of extremely preterm infants and is associated with increased mortality and morbidity. Nasal continuous positive airway pressure (nCPAP) is the most common post-extubation respiratory support, but there is no consensus on the optimal nCPAP level to safely avoid extubation failure in extremely preterm infants. We aimed to determine if higher nCPAP levels compared with standard nCPAP levels would decrease rates of extubation failure in extremely preterm infants within 7 days of their first extubation. METHODS: In this multicentre, randomised, open-label controlled trial done at three tertiary perinatal centres in Australia, we assigned extremely preterm infants to extubation to either higher nCPAP (10 cmH2O) or standard nCPAP (7 cmH2O). Infants were eligible if they were born at less than 28 weeks' gestation, were receiving mechanical ventilation via an endotracheal tube, and were being extubated for the first time to nCPAP. Eligible infants must have received previous treatment with exogenous surfactant and caffeine. Infants were ineligible if they were planned to be extubated to a mode of respiratory support other than nCPAP, if they had a known major congenital anomaly that might affect breathing, or if ongoing intensive care was not being provided. Parents or guardians provided prospective, written, informed consent. Infants were maintained within an assigned nCPAP range for a minimum of 24 h after extubation (higher nCPAP group 9-11 cmH2O and standard nCPAP group 6-8 cmH2O). Randomisation was stratified by both gestation (22-25 completed weeks or 26-27 completed weeks) and recruiting centre. The primary outcome was extubation failure within 7 days and analysis was by intention to treat. This trial was prospectively registered with the Australian New Zealand Clinical Trials Registry, number ACTRN12618001638224. FINDINGS: Between March 3, 2019, and July 31, 2022, 483 infants were born at less than 28 weeks and admitted to the recruiting centres. 92 infants were not eligible, 172 were not approached, 65 families declined to participate, and 15 consented but were not randomly assigned. 139 infants were enrolled and randomly assigned, 70 to the higher nCPAP group and 69 to the standard nCPAP group. One infant in the higher nCPAP group was excluded from the analysis because consent was withdrawn after randomisation. 104 (75%) of 138 mothers were White. The mean gestation was 25·7 weeks (SD 1·3) and the mean birthweight was 777 grams (201). 70 (51%) of 138 infants were female. Extubation failure occurred in 24 (35%) of 69 infants in the higher nCPAP group and in 39 (57%) of 69 infants in the standard nCPAP group (risk difference -21·7%, 95% CI -38·5% to -3·7%). There were no significant differences in rates of adverse events between groups during the primary outcome period. Three patients died (two in the higher nCPAP group and one in the standard nCPAP group), pneumothorax occurred in one patient from each group, spontaneous intestinal perforation in three patients (two in the higher nCPAP group and one in the standard nCPAP group) and there were no events of pulmonary interstitial emphysema. INTERPRETATION: Extubation of extremely preterm infants to higher nCPAP significantly reduced extubation failure compared with extubation to standard nCPAP, without increasing rates of adverse effects. Future larger trials are essential to confirm these findings in terms of both efficacy and safety. FUNDING: National Health and Medical Research Council Centre for Research Excellence in Newborn Medicine, number 1153176.
  • Item
    No Preview Available
    Heart Rate Changes following Facemask Placement in Infants Born at ≥32+0 Weeks of Gestation.
    Badurdeen, S ; Brooijmans, E ; Blank, DA ; Kuypers, KLAM ; Te Pas, AB ; Roberts, C ; Polglase, GR ; Hooper, SB ; Davis, PG (S. Karger AG, 2023)
    INTRODUCTION: Recent reports have raised concerns of cardiorespiratory deterioration in some infants receiving respiratory support at birth. We aimed to independently determine whether respiratory support with a facemask is associated with a decrease in heart rate (HR) in some late-preterm and term infants. METHODS: Secondary analysis of data from infants born at ≥32+0 weeks of gestation at 2 perinatal centres in Melbourne, Australia. Change in HR up to 120 s after facemask placement, measured using 3-lead electrocardiography, was assessed every 3 s until 60 s and every 5 s thereafter from video recordings. RESULTS: In the 15 s after facemask placement, 10/68 (15%) infants had a decrease in mean HR by >10 beats per minute (bpm) compared with their individual baseline mean HR in the 15 s before facemask placement. In 4 (6%) infants, HR decreased to <100 bpm. Nine out of 68 (13%) infants had an increase in mean HR by >10 bpm; 7 of these infants had a baseline HR <120 bpm. In univariable comparisons, the following characteristics were found not to be risk factors for a decrease in HR by >10 bpm: prematurity; type of respiratory support; hypoxaemia; early cord clamping; mode of birth; HR <120 bpm before mask placement. Six out of 63 infants (10%) who had HR ≥120 bpm after facemask placement had a late decrease in HR to <100 bpm between 30 and 120 s after facemask placement. CONCLUSION: Facemask respiratory support at birth is temporally associated with a decrease in HR in a subset of late-preterm and term infants.
  • Item
    No Preview Available
    Cerebral Oxygenation during Neonatal Intubation with Nasal High Flow: A Sub-Study of the SHINE Randomized Trial
    van der Veeken, E ; Manley, BJ ; Owen, L ; Kamlin, O ; Roberts, C ; Newman, S ; Francis, K ; Donath, S ; Davis, P ; Cuzzilla, R ; Hodgson, KA (KARGER, 2023-08)
    INTRODUCTION: Nasal high flow (nHF) improves the likelihood of successful neonatal intubation on the first attempt without physiological instability. The effect of nHF on cerebral oxygenation is unknown. The aim of this study was to compare cerebral oxygenation during endotracheal intubation in neonates receiving nHF and those receiving standard care. METHODS: A sub-study of a multicentre randomized trial of nHF during neonatal endotracheal intubation. A subset of infants had near-infrared spectroscopy (NIRS) monitoring. Eligible infants were randomly assigned to nHF or standard care during the first intubation attempt. NIRS sensors provided continuous regional cerebral oxygen saturation (rScO2) monitoring. The procedure was video recorded, and peripheral oxygen saturation and rScO2 data were extracted at 2-second intervals. The primary outcome was the average difference in rScO2 from baseline during the first intubation attempt. Secondary outcomes included average rScO2 and rate of change of rScO2. RESULTS: Nineteen intubations were analyzed (11 nHF; 8 standard care). Median (interquartile range [IQR]) postmenstrual age was 27 (26.5-29) weeks, and weight was 828 (716-1,135) g. Median change in rScO2 from baseline was -1.5% (-5.3 to 0.0) in the nHF group and -9.4% (-19.6 to -4.5) in the standard care group. rScO2 fell more slowly in infants managed with nHF compared with standard care: median (IQR) rScO2 change -0.08 (-0.13 to 0.00) % per second and -0.36 (-0.66 to -0.22) % per second, respectively. CONCLUSIONS: In this small sub-study, regional cerebral oxygen saturation was more stable in neonates who received nHF during intubation compared with standard care.
  • Item
    No Preview Available
    Estimating Preterm Lung Volume: A Comparison of Lung Ultrasound, Chest Radiography, and Oxygenation
    Sett, A ; Rogerson, SR ; Foo, GWC ; Keene, J ; Thomas, N ; Kee, PPL ; Zayegh, A ; Donath, SM ; Tingay, DG ; Davis, PG ; Manley, BJ (MOSBY-ELSEVIER, 2023-08)
    OBJECTIVE: To determine the relationship between lung ultrasound (LUS) examination, chest radiograph (CXR), and radiographic and clinical evaluations in the assessment of lung volume in preterm infants. STUDY DESIGN: In this prospective cohort study LUS was performed before CXR on 70 preterm infants and graded using (1) a LUS score, (2) an atelectasis score, and (3) measurement of atelectasis depth. Radiographic diaphragm position and radio-opacification were used to determine global and regional radiographic atelectasis. The relationship between LUS, CXR, and oxygenation was assessed using receiver operator characteristic and correlation analysis. RESULTS: LUS scores, atelectasis scores, and atelectasis depth did not correspond with radiographic global atelectasis (area under receiver operator characteristics curves, 0.54 [95% CI, 0.36-0.71], 0.49 [95% CI, 0.34-0.64], and 0.47 [95% CI, 0.31-0.64], respectively). Radiographic atelectasis of the right upper, right lower, left upper, and left lower quadrants was predicted by LUS scores (0.75 [95% CI, 0.59-0.92], 0.75 [95% CI, 0.62-0.89], 0.69 [95% CI, 0.56-0.82], and 0.63 [95% CI, 0.508-0.751]) and atelectasis depth (0.66 [95% CI, 0.54-0.78], 0.65 [95% CI, 0.53-0.77], 0.63 [95% CI, 0.50-0.76], and 0.56 [95% CI, 0.44-0.70]). LUS findings were moderately correlated with oxygen saturation index (ρ = 0.52 [95% CI, 0.30-0.70]) and saturation to fraction of inspired oxygen ratio (ρ = -0.63 [95% CI, -0.76 to -0.46]). The correlation between radiographic diaphragm position, the oxygenation saturation index, and peripheral oxygen saturation to fraction of inspired oxygen ratio was very weak (ρ = 0.36 [95% CI, 0.11-0.59] and ρ = -0.32 [95% CI, -0.53 to -0.07], respectively). CONCLUSIONS: LUS assessment of lung volume does not correspond with radiographic diaphragm position preterm infants. However, LUS predicted radiographic regional atelectasis and correlated with oxygenation. The relationship between radiographic diaphragm position and oxygenation was very weak. Although LUS may not replace all radiographic measures of lung volume, LUS more accurately reflects respiratory status in preterm infants. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry: ACTRN12621001119886.
  • Item
  • Item
    Thumbnail Image
    The 5-minute Apgar score and childhood school outcomes
    Selvaratnam, RJ ; Wallace, EM ; Davis, PG ; Rolnik, DL ; Fahey, M ; Davey, M-A (WILEY, 2022-10)
    AIM: To examine the association between Apgar score at 5 min and childhood developmental and educational outcome. METHODS: A population-based data linkage study of births ≥37 weeks' gestation linked to developmental outcomes at preparatory school and educational outcomes at school grades 3, 5 and 7 in Victoria, Australia. Multivariable logistic regressions and generalised estimating equations were used. RESULTS: There were 167,126 singleton infants with developmental results and 392,933 singleton infants with at least one educational result. There was an inverse relationship between Apgar score at 5 min and poor developmental and educational outcomes, with the worst outcomes among Apgar scores of 0-3. Apgar scores of 7, 8 and 9 were all associated with poorer developmental outcomes (aOR = 1.31, 95% CI: 1.12-1.54; aOR = 1.17, 95% CI: 1.05-1.29; aOR = 1.08, 95% CI: 1.02-1.13 respectively), while Apgar scores of 7 and 8 were associated with poorer educational outcomes at grades 3, 5, and 7. With progression through grades 3, 5, and 7, the extent of the difference in educational outcomes diminished (e.g. for Apgar scores of 0-3: aOR = 3.33, 95% CI: 1.85-6.00 in grade 3 and aOR = 1.49, 95% CI: 0.75-2.96 in grade 7). CONCLUSION: Apgar scores below 10 at 5 min are associated with poorer developmental and educational outcomes in school.
  • Item
    Thumbnail Image
    Respiratory outcomes in preterm babies: Is bronchopulmonary dysplasia important?
    Barrington, KJ ; Church, PT ; Luu, TM ; Davis, PG (WILEY, 2022-09)
  • Item