Veterinary Clinical Sciences - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 4 of 4
  • Item
    Thumbnail Image
    Lean body weight-adjusted intravenous iodinated contrast dose for abdominal CT in dogs reduces interpatient enhancement variability while providing diagnostic quality organ enhancement
    Kan, J ; Milne, M ; Tyrrell, D ; Mansfield, C (WILEY, 2022-11)
    Contrast-enhanced computed tomography (CECT) is increasingly used to screen for abdominal pathology in dogs, and the contrast dose used is commonly calculated as a linear function of total body weight (TBW). Body fat is not metabolically active and contributes little to dispersing or diluting contrast medium (CM) in the blood. This prospective, analytic, cross-section design pilot study aimed to establish the feasibility of intravenous CM dosed according to lean body weight (LBW) for abdominal CECT in dogs compared to TBW. We hypothesized that when dosing intravenous CM according to LBW, studies will remain at diagnostic quality, there will be a reduced interindividual contrast enhancement (CE) variability, and there will be less change to heart rate and blood pressure in dogs compared to when administering CM calculated on TBW. Twelve dogs had two CECT studies with contrast doses according to TBW and LBW at least 8 weeks apart. Interindividual organ and vessel CE variability, diagnostic quality of the studies, and changes in physiological status were compared between protocols. The LBW-based protocol provided less variability in the CE of most organs and vessels (except the aorta). When dosed according to LBW, liver enhancement was positively associated with grams of iodine per kg TBW during the portal venous phase (P = 0.046). There was no significant difference in physiological parameters after CM administration between dosing protocols. Our conclusion is that a CM dose based on LBW for abdominal CECT lowers interindividual CE variability and is effective at maintaining studies of diagnostic quality.
  • Item
    Thumbnail Image
    Scintigraphic Assessment of Deposition of Radiolabeled Fluticasone Delivered from a Nebulizer and Metered Dose Inhaler in 10 Healthy Dogs
    Chow, KE ; Tyrrell, D ; Yang, M ; Abraham, LA ; Anderson, GA ; Mansfield, CS (WILEY, 2017-11)
    BACKGROUND: Aerosolized medications are increasingly being used to treat respiratory diseases in dogs. No previous studies assessing respiratory tract deposition of radiolabeled aerosols have been performed in conscious dogs. HYPOTHESIS/OBJECTIVES: Assess respiratory tract deposition of radiolabeled, inhalant corticosteroid (fluticasone propionate labeled with 99m Tc) delivered from a nebulizer and metered dose inhaler (MDI) to healthy dogs. ANIMALS: Ten healthy Foxhounds. METHODS: Prospective, randomized, cross-over pilot study. Initial inhalation method (nebulizer or MDI) was randomly assigned. Treatments were crossed over after a 7-day washout period. Treatments initially were performed using sedation. Dogs were imaged using 2-dimensional planar scintigraphy, with respiratory tract deposition quantified by manual region-of-interest analysis. Deposition calculated as percentage of delivered dose. Six of 10 dogs were randomly selected and reassessed without sedation. RESULTS: Inhalation method had significant effect on respiratory tract deposition (P = 0.027). Higher deposition was achieved by nebulization with mean deposition of 4.2% (standard deviation [SD], 1.4%; range, 1.9-6.1%); whereas MDI treatment achieved a mean of 2.3% (SD, 1.4%; range, 0.2-4.2%). Nebulization achieved higher respiratory tract deposition than MDI in 7 of 10 dogs. No statistical difference (P = 0.68) was found between mean respiratory tract deposition achieved in dogs when unsedated (3.8%; SD, 1.5%) or sedated (3.6%; SD, 1.7%). CONCLUSIONS AND CLINICAL IMPORTANCE: Study confirms respiratory tract deposition of inhalant medications delivered from a nebulizer and MDI in healthy dogs, breathing tidally with and without sedation. Respiratory tract deposition in these dogs was low compared to reported deposition in adult humans, but similar to reported deposition in children.
  • Item
    Thumbnail Image
    Abdominal volume computed tomography assessment of body composition in dogs
    Turner, RBS ; Hepworth, G ; Wilson, K ; Tyrrell, D ; Dunshea, FR ; Mansfield, CS (BMC, 2019-01-08)
    BACKGROUND: Computed tomography (CT) has been used to estimate body composition and determine tissue distribution in dogs, despite limited validation. This may introduce error into estimates of body composition studies and its effect on health in dogs. Further, the modality has not been validated against dual-energy X-ray absorptiometry (DXA) or over a wide range of dog breeds, ages and sexes. The objective of this study was to validate the use of semi-automated, abdominal volume CT for estimating total body composition of dogs relative to DXA. Twenty-two staff-owned dogs (weighing between 5.1-60 kg) were sedated and underwent full body DXA scan and abdominal CT. Abdominal tissue composition was estimated by CT using semi-automated volume segmentation, over predetermined tissue Hounsfield threshold values. Abdominal tissue composition determined by the various CT threshold ranges was compared to total body composition determined by DXA. RESULTS: Abdominal tissue composition estimated by CT strongly correlated with the estimates derived from DXA with a small Bland-Altman mean percentage differences in values: total body mass (- 250/2000HU: r2 = 0.985; - 1.10%); total fat mass (- 250/-25HU: r2 = 0.981; - 1.90%); total lean tissue mass (- 25/150HU: r2 = 0.972; 3.47%); and total bone mineral content (150/2000HU: r2 = 0.900; - 0.87%). Although averaged CT values compared well to DXA analysis, there was moderate variation in the individual predicted values. There was near perfect inter- and intra-observer agreement in segmentation volumes for abdominal fat. CONCLUSIONS: Abdominal volume computed tomography (CT) accurately and reliably estimates total body composition in dogs, but greater variations may be observed in dogs weighing less than 10 kg.
  • Item
    Thumbnail Image
    Compartmental fat distribution in the abdomen of dogs relative to overall body fat composition
    Turner, RBS ; Tyrrell, D ; Hepworth, G ; Dunshea, FR ; Mansfield, CS (BMC, 2020-03-30)
    BACKGROUND: Adipose tissue may have different metabolic and endocrine functions depending on the region of the body in which it is located. While visceral or intra-abdominal fat has been found to contribute to leptin concentrations, insulin resistance and obesity-related diseases, there are only a few imaging studies documenting the preferential distribution of body fat to either the intra-abdominal or subcutaneous compartments in dogs. This study aimed to determine if CT-measured abdominal fat distributed preferentially to the visceral space (V) relative to the subcutaneous space (SQ), with increasing DXA-determined total body fat percentage; and if ultrasound measurements of the ventral midline subcutaneous (SAT) and visceral adipose thickness (VAT) can be used to estimate the distribution of fat to the subcutaneous and visceral abdominal spaces, in a sample of 22 dogs with variable body condition. RESULTS: Multivariate analysis showed no statistically significant correlation between visceral to subcutaneous fat ratio (V/SQ) and increasing total body fat percentage (β = - 0.07, p = 0.733), but strong correlation with age (β = 0.71 p = 0.002). A substantial amount of variation for the ultrasound visceral adipose thickness to subcutaneous fat thickness (VAT/SAT) could be explained by both CT V/SQ and sex (R2Adjusted = 0.477, p = 0.001), with female dogs having significant lower VAT/SAT ratios compared to the male dogs (p = 0.047). The ultrasound fat measurements appeared moderately reliable, but a larger sample number is required to confirm this. CONCLUSIONS: The findings suggest that dogs with a relatively healthy to slightly overweight body condition score, distribute fat relatively similarly between their peritoneal (visceral) and subcutaneous abdominal compartments with increasing total body fat percentage. However, there was increased fat distribution to the peritoneal space relative to the subcutaneous space with increasing age. Further, abdominal ultrasound may be useful in estimating the ratio of fat distribution to both the abdominal visceral and subcutaneous spaces.