  • Item
    No Preview Available
    Characteristics of the Summating Potential Measured Across a Cochlear Implant Array as an Indicator of Cochlear Function.
    Panario, J ; Bester, C ; O'Leary, SJ (Ovid Technologies (Wolters Kluwer Health), 2023-09)
    OBJECTIVES: The underlying state of cochlear and neural tissue function is known to affect postoperative speech perception following cochlear implantation. The ability to assess these tissues in patients can be performed using intracochlear electrocochleography (IC ECochG). One component of ECochG is the summating potential (SP) that appears to be generated by multiple cochlear tissues. Its qualities may be able to detect the presence of functional inner hair cells, but evidence for this is limited in human cochleae. This study aimed to examine the IC SP characteristics in cochlear implantation recipients, its relationship to preoperative speech perception and audiometric thresholds, and to other IC ECochG components. DESIGN: This is a retrospective analysis of 113 patients' IC ECochG recordings across the array in response to a 500 Hz tone burst stimulus. Responses to condensation and rarefaction stimuli were then subtracted from one another to emphasize the cochlear microphonic and added to one another to emphasize the SP, auditory nerve neurophonic, and compound action potential. Patients were grouped based on their maximum SP deflection being large and positive (+SP), large and negative (-SP), or minimal (0 SP) to further investigate these relationships. RESULTS: Patients in the +SP group had better preoperative speech perception (mean consonant-vowel-consonant phoneme score 46%) compared to the -SP and 0 SP groups (consonant-vowel-consonant phoneme scores 34% and 36%, respectively, difference to +SP: p < 0.05). Audiometric thresholds were lowest for +SP (mean pure-tone average 50 dB HL), then -SP (65 dB HL), and highest for 0 SP patients (70 dB HL), but there was not a statistical significance between +SP and -SP groups ( p > 0.1). There were also distinct differences between SP groups in the qualities of their other ECochG components. These included the +SP patients having larger cochlear microphonic maximum amplitude, more apical SP peak electrode locations, and a more spatially specific SP magnitude growth pattern across the array. CONCLUSIONS: Patients with large positive SP deflection in IC ECochG have preoperatively better speech perception and lower audiometric thresholds than those without. Patterns in other ECochG components suggest its positive deflection may be an indicator of cochlear function.
  • Item
    No Preview Available
    Intra-cochlear Flushing Reduces Tissue Response to Cochlear Implantation
    Razmovski, T ; Brody, KM ; Stathopoulos, D ; Zhang, D ; Cho, E ; Hampson, AJ ; Collins, A ; Bester, C ; O'Leary, S (WILEY, 2024-03)
    INTRODUCTION: Intraoperative trauma leading to bleeding during cochlear implantation negatively impacts residual hearing of cochlear implant recipients. There are no clinical protocols for the removal of blood during implantation, to reduce the consequential effects such as inflammation and fibrosis which adversely affect cochlear health and residual hearing. This preclinical study investigated the implementation of an intra-cochlear flushing protocol for the removal of blood. METHODS: Three groups of guinea pigs were studied for 28 days after cochlear implantation; cochlear implant-only (control group); cochlear implant with blood injected into the cochlea (blood group); and cochlear implant, blood injection, and flushing of the blood from the cochlea intraoperatively (flush group). Auditory brainstem responses (ABRs) in addition to tissue response volumes were analyzed and compared between groups. RESULTS: After implantation, the blood group exhibited the highest ABR thresholds when compared to the control and flush group, particularly in the high frequencies. On the final day, the control and blood group had similar ABR thresholds across all frequencies tested, whereas the flush group had the lowest thresholds, significantly lower at 24 kHz than the blood and control group. Analysis of the tissue response showed the flush group had significantly lower tissue responses in the basal half of the array when compared with the blood and control group. CONCLUSIONS: Flushing intra-cochlear blood during surgery resulted in better auditory function and reduced subsequent fibrosis in the basal region of the cochlea. This finding prompts the implementation of a flushing protocol in clinical cochlear implantation. LEVEL OF EVIDENCE: N/A Laryngoscope, 134:1410-1416, 2024.
  • Item
    No Preview Available
    Electrocochleography triggered intervention successfully preserves residual hearing during cochlear implantation: Results of a randomised clinical trial
    Bester, C ; Collins, A ; Razmovski, T ; Weder, S ; Briggs, RJ ; Wei, B ; Zakaria, AF ; Gerard, J-M ; Mitchell-Innes, A ; Tykocinski, M ; Kennedy, R ; Iseli, C ; Dahm, M ; Ellul, S ; O'Leary, S (ELSEVIER, 2022-12)
    BACKGROUND: Preservation of natural hearing during cochlear implantation is associated with improved speech outcomes, however more than half of implant recipients lose this hearing. Real-time electrophysiological monitoring of cochlear output during implantation, made possible by recording electrocochleography using the electrodes on the cochlear implant, has shown promise in predicting hearing preservation. Sudden drops in the amplitude of the cochlear microphonic (CM) have been shown to predict more severe hearing losses. Here, we report on a randomized clinical trial investigating whether immediate surgical intervention triggered by these drops can save residual hearing. METHODS: A single-blinded placebo-controlled trial of surgical intervention triggered when CM amplitude dropped by at least 30% of a prior maximum amplitude during cochlear implantation. Intraoperative electrocochleography was recorded in 60 adults implanted with Cochlear Ltd's Thin Straight Electrode, half randomly assigned to a control group and half to an interventional group. The surgical intervention was to withdraw the electrode in ½-mm steps to recover CM amplitude. The primary outcome was hearing preservation 3 months following implantation, with secondary outcomes of speech-in-noise reception thresholds by group or CM outcome, and depth of implantation. RESULTS: Sixty patients were recruited; neither pre-operative audiometry nor speech reception thresholds were significantly different between groups. Post-operatively, hearing preservation was significantly better in the interventional group. This was the case in absolute difference (median of 30 dB for control, 20 dB for interventional, χ² = 6.2, p = .013), as well as for relative difference (medians of 66% for the control, 31% for the interventional, χ² = 5.9, p = .015). Speech-in-noise reception thresholds were significantly better in patients with no CM drop at any point during insertion compared with patients with a CM drop; however, those with successfully recovered CMs after an initial drop were not significantly different (median gain required for speech reception score of 50% above noise of 6.9 dB for no drop, 8.6 for recovered CM, and 9.8 for CM drop, χ² = 6.8, p = .032). Angular insertion depth was not significantly different between control and interventional groups. CONCLUSIONS: This is the first demonstration that surgical intervention in response to intraoperative hearing monitoring can save residual hearing during cochlear implantation.
  • Item
    Thumbnail Image
    Monitoring Cochlear Health With Intracochlear Electrocochleography During Cochlear Implantation: Findings From an International Clinical Investigation
    O'Leary, S ; Mylanus, E ; Venail, F ; Lenarz, T ; Birman, C ; Di Lella, F ; Roland Jr, JT ; Gantz, B ; Beynon, A ; Sicard, M ; Buechner, A ; Lai, WK ; Boccio, C ; Choudhury, B ; Tejani, VD ; Plant, K ; English, R ; Arts, R ; Bester, C (LIPPINCOTT WILLIAMS & WILKINS, 2023-03)
    OBJECTIVES: Electrocochleography (ECochG) is emerging as a tool for monitoring cochlear function during cochlear implant (CI) surgery. ECochG may be recorded directly from electrodes on the implant array intraoperatively. For low-frequency stimulation, its amplitude tends to rise or may plateau as the electrode is inserted. The aim of this study was to explore whether compromise of the ECochG signal, defined as a fall in its amplitude of 30% or more during insertion, whether transient or permanent, is associated with poorer postoperative acoustic hearing, and to examine how preoperative hearing levels may influence the ability to record ECochG. The specific hypotheses tested were threefold: (a) deterioration in the pure-tone average of low-frequency hearing at the first postoperative follow-up interval (follow-up visit 1 [FUV1], 4 to 6 weeks) will be associated with compromise of the cochlear microphonic (CM) amplitude during electrode insertion (primary hypothesis); (b) an association is observed at the second postoperative follow-up interval (FUV2, 3 months) (secondary hypothesis 1); and (c) the CM response will be recorded earlier during electrode array insertion when the preoperative high-frequency hearing is better (secondary hypothesis 2). DESIGN: International, multi-site prospective, observational, between groups design, targeting 41 adult participants in each of two groups, (compromised CM versus preserved CM). Adult CI candidates who were scheduled to receive a Cochlear Nucleus CI with a Slim Straight or a Slim Modiolar electrode array and had a preoperative audiometric low-frequency average thresholds of ≤80 dB HL at 500, 750, and 1000 Hz in the ear to be implanted, were recruited from eight international implant sites. Pure tone audiometry was measured preoperatively and at postoperative visits (FUV1 and follow-up visit 2 [FUV2]). ECochG was measured during and immediately after the implantation of the array. RESULTS: From a total of 78 enrolled individuals (80 ears), 77 participants (79 ears) underwent surgery. Due to protocol deviations, 18 ears (23%) were excluded. Of the 61 ears with ECochG responses, amplitudes were < 1 µV throughout implantation for 18 ears (23%) and deemed "unclear" for classification. EcochG responses >1 µV in 43 ears (55%) were stable throughout implantation for 8 ears and compromised in 35 ears. For the primary endpoint at FUV1, 7/41 ears (17%) with preserved CM had a median hearing loss of 12.6 dB versus 34/41 ears (83%) with compromised CM and a median hearing loss of 26.9 dB ( p < 0.014). In assessing the practicalities of measuring intraoperative ECochG, the presence of a measurable CM (>1 µV) during implantation was dependent on preoperative, low-frequency thresholds, particularly at the stimulus frequency (0.5 kHz). High-frequency, preoperative thresholds were also associated with a measurable CM > 1 µV during surgery. CONCLUSIONS: Our data shows that CM drops occurring during electrode insertion were correlated with significantly poorer hearing preservation postoperatively compared to CMs that remained stable throughout the electrode insertion. The practicality of measuring ECochG in a large cohort is discussed, regarding the suggested optimal preoperative low-frequency hearing levels ( < 80 dB HL) considered necessary to obtain a CM signal >1 µV.
  • Item
    Thumbnail Image
    Automatic analysis of cochlear response using electrocochleography signals during cochlear implant surgery
    Wijewickrema, S ; Bester, C ; Gerard, J-M ; Collins, A ; O'Leary, S ; Buechner, A (PUBLIC LIBRARY SCIENCE, 2022-07-14)
    Cochlear implants (CIs) provide an opportunity for the hearing impaired to perceive sound through electrical stimulation of the hearing (cochlear) nerve. However, there is a high risk of losing a patient's natural hearing during CI surgery, which has been shown to reduce speech perception in noisy environments as well as music appreciation. This is a major barrier to the adoption of CIs by the hearing impaired. Electrocochleography (ECochG) has been used to detect intra-operative trauma that may lead to loss of natural hearing. There is early evidence that ECochG can enable early intervention to save natural hearing of the patient. However, detection of trauma by observing changes in the ECochG response is typically carried out by a human expert. Here, we discuss a method of automating the analysis of cochlear responses during CI surgery. We establish, using historical patient data, that the proposed method is highly accurate (∼94% and ∼95% for sensitivity and specificity respectively) when compared to a human expert. The automation of real-time cochlear response analysis is expected to improve the scalability of ECochG and improve patient safety.
  • Item
    No Preview Available
    Spironolactone Ameliorates Cochlear Implant Induced Endolymphatic Hydrops.
    Creber, NJ ; Eastwood, HT ; Hampson, AJ ; Lo, J ; Zhang, D ; Chambers, SA ; Bester, CW ; Thorne, PR ; O'Leary, SJ (Ovid Technologies (Wolters Kluwer Health), 2022-07-01)
    BACKGROUND: Endolymphatic hydrops (EH) has been observed in both animal and human cochleae following cochlear implant (CI) surgery. We tested whether EH could be eliminated by administration of mineralocorticoid steroid antagonist spironolactone and explored the electrophysiological consequences of this. METHODS: Sixty-four adult guinea pigs underwent cochlear implantation with a dummy electrode. Animals then survived either 2, 7, or 28 days. Auditory function was monitored by recording electrocochleography from the round window membrane preimplantation, and on the last day of the experiment. Spironolactone or control solution was added to animals' feed for 7 days (if they survived that long) beginning immediately prior to surgery. The presence of EH was determined using thin-sheet laser imaging microscopy. RESULTS: Treatment with spironolactone resulted in significant reduction in EH in the second cochlear turn 7 days postimplantation. In all animals, the compound action potential (CAP) threshold was elevated 2 days postimplantation, but for most frequencies had recovered substantially by 28 days. There was no treatment effect on CAP thresholds. SP/AP ratios were elevated at day 2. The amplitude growth of the CAP did not differ between test and control groups at any time after implantation. CONCLUSIONS: EH can be suppressed by antagonism of mineralocorticoid receptors in the week after cochlear implantation. Reduction in EH did not lead to any change in hearing, and there was no indication of synaptopathy signalled by reduced CAP amplitude at high sound intensities. We found no electrophysiological evidence that EH early after implantation impacts negatively upon preservation of residual hearing.
  • Item
    Thumbnail Image
    A new "practical" plane for Eustachian tube measurements and its application in predicting middle ear dysfunction in patient with acquired cholesteatomas
    Ku, D ; Copson, B ; Fiorentino, M ; Gerrard, J-M ; O'Leary, S (SPRINGER, 2022-10)
    SETTING: The Eustachian tube plays a vital role in middle ear physiology. There has been evidence that Eustachian tube (ET) and angle are correlated with middle ear function. The measurements of these Eustachian tube features are now made possible with computed tomography and multiplanar reconstruction techniques. However, there has not been a standardised protocol devised to these measurements in limited window cone-beam CT scans of temporal bones. OBJECTIVE: The primary object of the present study is to establish and validate a new landmark in closer proximity to the middle ear that is consistently captured, thereby allowing ET angle and length to be measured from the majority of cone-beam CT scans. Secondarily, the ET anatomies of patients with middle ear dysfunction manifesting as acquired cholesteatoma are analysed with this new method of measurement. METHODS: This study undertook a step-by-step method to first validate the methods of ET measurement with Reid's standard plane, then identifying an alternative landmark, thus a new plane visible on limited window cone-beam CT scans of temporal bones and lastly, validating the application of this new plane in the measurements of ET angle and length. This new method of measurement was coined the Ku-Copson plane and was applied to 30 cochlear implant patients and 30 patients with acquired cholesteatomas. Their ET anatomies were analysed and compared. RESULTS: It was found that the new Ku-Copson mandibular fossa plane was a reliable and accurate plane for the measurement of ET angle and length. Furthermore, it was found that patients with acquired cholesteatomas have statistically significant smaller ET angles and shorter ET lengths when compared with patients with cochlear implants, of normal middle ear function. CONCLUSION: The newly proposed method utilising the right mandibular fossa as an anatomical landmark for ET angles and lengths measurement appears to be viable. The close proximity of this landmark to the middle ear means that it is highly likely to be captured in most cone-beam CT scans of the petrous temporal bones. This enables the retrospective examination ET angles and lengths to be conducted on CB CT scans. This study reports statistically significant difference in ET anatomy in patients with middle ear dysfunction.
  • Item
    Thumbnail Image
    A Deep Learning Framework for Segmenting Brain Tumors Using MRI and Synthetically Generated CT Images
    Islam, KT ; Wijewickrema, S ; O'Leary, S (MDPI, 2022-01)
    Multi-modal three-dimensional (3-D) image segmentation is used in many medical applications, such as disease diagnosis, treatment planning, and image-guided surgery. Although multi-modal images provide information that no single image modality alone can provide, integrating such information to be used in segmentation is a challenging task. Numerous methods have been introduced to solve the problem of multi-modal medical image segmentation in recent years. In this paper, we propose a solution for the task of brain tumor segmentation. To this end, we first introduce a method of enhancing an existing magnetic resonance imaging (MRI) dataset by generating synthetic computed tomography (CT) images. Then, we discuss a process of systematic optimization of a convolutional neural network (CNN) architecture that uses this enhanced dataset, in order to customize it for our task. Using publicly available datasets, we show that the proposed method outperforms similar existing methods.
  • Item
    Thumbnail Image
    Ear, nose and throat surgery: All you need to know about the surgical approach to the management of middle-ear effusions in Australian Indigenous and non-Indigenous children
    Kong, K ; Lannigan, FJ ; Morris, PS ; Leach, AJ ; O'Leary, SJ (WILEY, 2017-11)
    Otitis media (OM) is a common condition in Australia. It represents a spectrum of diseases from otitis media with effusion (OME) to chronic suppurative otitis media. For all the OM diagnoses, Australian Indigenous children have higher rates of early onset, severe and persistent disease. OME is the most common form of OM and often occurs after an upper respiratory tract infection. It can be difficult to diagnose (and often goes unrecognised). Hearing loss is the most important complication. The middle-ear effusion impedes the movement of the tympanic membrane and causes a conductive hearing loss of around 25 dB. Around 20% will have a hearing loss exceeding 35 dB. Children with early onset, persistent, bilateral OME and hearing loss (or speech delay) are most likely to benefit from interventions. However, the impact of all the effective treatment options is modest. Giving advice about effective communication strategies for young children is always appropriate. The best evidence from randomised trials supports not using antihistamines and/or decongestants, considering a trial of antibiotics and referral for tympanostomy tubes. Despite the availability of evidence-based guidelines, giving advice about treatment is a challenge because recommendations vary according to condition, age, risk of complications and parental preference. While most children with OME can be effectively managed in primary care, we need to get children who meet the criteria for simple ear, nose and throat procedures that improve hearing on to ear, nose and throat surgery waiting lists. Long delays in hearing support may contribute to life-long social and economic disadvantage.
  • Item
    Thumbnail Image
    Effect of cochlear implantation on middle ear function: A three-month prospective study
    Wasson, JD ; Campbell, L ; Chambers, S ; Hampson, A ; Briggs, RJS ; O'Leary, SJ (WILEY, 2018-05)
    OBJECTIVES/HYPOTHESIS: To determine if cochlear implantation has a delayed effect on the middle ear conductive hearing mechanism by measuring laser Doppler vibrometry (LDV) of the tympanic membrane (TM) in both implanted and contralateral control ears preoperatively and 3 months postoperatively, and then comparing the relative change in LDV outcome measures between implanted and control ears. STUDY DESIGN: Prospective cohort study. METHODS: Eleven preoperative adult unilateral cochlear implant recipients in previously unoperated ears with normal anatomy and aerated temporal bones were included in this study. The magnitude and phase angle of umbo velocity transfer function in response to air- conduction (AC) stimulus, and the magnitude of umbo velocity in response to bone- conduction (BC) stimulus were measured in the implant ear and the contralateral control ear preoperatively and 3 months postoperatively and compared. RESULTS: No significant changes in the magnitude or phase angle of TM velocity in response to either AC or BC stimulus were observed in the implanted ear relative to the contralateral control ear 3 months following cochlear implantation. CONCLUSIONS: From the results of LDV measurements, it can be said that cochlear implantation has no significant delayed effect on the middle ear conductive mechanism. LEVEL OF EVIDENCE: 4. Laryngoscope, 128:1207-1212, 2018.