Electrical and Electronic Engineering - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 2 of 2
  • Item
    Thumbnail Image
    Investigating scale invariant dynamics in minimum toe clearance variability of the young and elderly during treadmill walking
    Khandoker, AH ; Taylor, SB ; Karmakar, CK ; Begg, RK ; Palaniswami, M (IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 2008-08)
    Current research applying variability measures of gait parameters has demonstrated promise for helping to solve one of the "holy grails" of geriatric research by defining markers that can be used to prospectively identify persons at risk of falling . The minimum toe clearance (MTC) event occurs during the leg swing phase of the gait cycle and is a task highly sensitive to the spatial and balance control properties of the locomotor system. The aim of this study is to build upon the current state of research by investigating the magnitude and dynamic structure from the MTC time series fluctuations due to aging and locomotor disorder. Thirty healthy young (HY), 27 healthy elderly (HE), and 10 falls risk (FR) elderly individuals (who presented a prior history of trip-related falls) participated in treadmill walking for at least 10 min at their preferred speed. Continuous MTC data were collected and the first 512 data points were analyzed. The following variability indices were quantified: 1) MTC mean and standard deviation (SD), 2) PoincarE plot indices of MTC variability (SD1, SD2, SD1/SD2), 3) a wavelet based multiscale exponent beta to describe the dynamic structure of MTC fluctuations, and 4) detrended fluctuation analysis exponent alpha to investigate the presence of long-range correlations in MTC time series data. Results showed that stride-to-stride MTC time series has a nonlinear structure in all three groups when compared against randomly shuffled surrogate MTC data. Test on aging effects showed the MTC central tendency was significantly lower (p < 0.01) and the magnitude of the MTC variability significantly higher (p < 0.01). This trend changed when comparing FR subjects against age-matched HE as both the central tendency (p < 0.01) and magnitude of the variability (p < 0.01) increased significantly in FR. Although the magnitude of MTC variability increased with age, the nonlinear indices represented by alpha, beta, and SD1/SD2 demonstrated that the nonlinear structure of MTC does not change significantly due to aging (p > 0.05). There were, however, significant differences between HY and FR for beta (between scale 1 and 2; p < 0.01) and alpha (p < 0.05). Out of all the variability measures applied, beta(Wv2-4), SD1/SD2, SD2 of critical MTC parameter were found to be potential markers to be able to reliably identify FR from HE subjects. Further research is required to understand the mechanisms underlying the cause of MTC variability.
  • Item
    Thumbnail Image
    Support Vector Machines for Automated Recognition of Obstructive Sleep Apnea Syndrome From ECG Recordings
    Khandoker, AH ; Palaniswami, M ; Karmakar, CK (IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 2009-01)
    Obstructive sleep apnea syndrome (OSAS) is associated with cardiovascular morbidity as well as excessive daytime sleepiness and poor quality of life. In this study, we apply a machine learning technique [support vector machines (SVMs)] for automated recognition of OSAS types from their nocturnal ECG recordings. A total of 125 sets of nocturnal ECG recordings acquired from normal subjects (OSAS - ) and subjects with OSAS (OSAS +), each of approximately 8 h in duration, were analyzed. Features extracted from successive wavelet coefficient levels after wavelet decomposition of signals due to heart rate variability (HRV) from RR intervals and ECG-derived respiration (EDR) from R waves of QRS amplitudes were used as inputs to the SVMs to recognize OSAS +/- subjects. Using leave-one-out technique, the maximum accuracy of classification for 83 training sets was found to be 100% for SVMs using a subset of selected combination of HRV and EDR features. Independent test results on 42 subjects showed that it correctly recognized 24 out of 26 OSAS + subjects and 15 out of 16 OSAS - subjects (accuracy = 92.85%; Cohen's kappa value of 0.85). For estimating the relative severity of OSAS, the posterior probabilities of SVM outputs were calculated and compared with respective apnea/hypopnea index. These results suggest superior performance of SVMs in OSAS recognition supported by wavelet-based features of ECG. The results demonstrate considerable potential in applying SVMs in an ECG-based screening device that can aid a sleep specialist in the initial assessment of patients with suspected OSAS.