Electrical and Electronic Engineering - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 5 of 5
  • Item
    Thumbnail Image
    An ab-initio Computational Method to Determine Dielectric Properties of Biological Materials
    Abeyrathne, CD ; Halgamuge, MN ; Farrell, PM ; Skafidas, E (NATURE PUBLISHING GROUP, 2013-05-08)
    Frequency dependent dielectric properties are important for understanding the structure and dynamics of biological materials. These properties can be used to study underlying biological processes such as changes in the concentration of biological materials, and the formation of chemical species. Computer simulations can be used to determine dielectric properties and atomic details inaccessible via experimental methods. In this paper, a unified theory utilizing molecular dynamics and density functional theory is presented that is able to determine the frequency dependent dielectric properties of biological materials in an aqueous solution from their molecular structure alone. The proposed method, which uses reaction field approximations, does not require a prior knowledge of the static dielectric constant of the material. The dielectric properties obtained from our method agree well with experimental values presented in the literature.
  • Item
    Thumbnail Image
    A Label-Free, Quantitative Fecal Hemoglobin Detection Platform for Colorectal Cancer Screening
    Soraya, GV ; Nguyen, TC ; Abeyrathne, CD ; Huynh, DH ; Chan, J ; Nguyen, PD ; Nasr, B ; Chana, G ; Kwan, P ; Skafidas, E (MDPI, 2017-06)
    The early detection of colorectal cancer is vital for disease management and patient survival. Fecal hemoglobin detection is a widely-adopted method for screening and early diagnosis. Fecal Immunochemical Test (FIT) is favored over the older generation chemical based Fecal Occult Blood Test (FOBT) as it does not require dietary or drug restrictions, and is specific to human blood from the lower digestive tract. To date, no quantitative FIT platforms are available for use in the point-of-care setting. Here, we report proof of principle data of a novel low cost quantitative fecal immunochemical-based biosensor platform that may be further developed into a point-of-care test in low-resource settings. The label-free prototype has a lower limit of detection (LOD) of 10 µg hemoglobin per gram (Hb/g) of feces, comparable to that of conventional laboratory based quantitative FIT diagnostic systems.
  • Item
    Thumbnail Image
    Rapid Detection of HLA-B*57:01-Expressing Cells Using a Label-Free Interdigitated Electrode Biosensor Platform for Prevention of Abacavir Hypersensitivity in HIV Treatment
    Chan, J ; Soraya, GV ; Craig, L ; Uddin, SM ; Todaro, M ; Huynh, DH ; Abeyrathne, CD ; Kostenko, L ; McCluskey, J ; Skafidas, E ; Kwan, P (MDPI AG, 2019-08-20)
    Pre-treatment screening of individuals for human leukocyte antigens (HLA) HLA-B*57:01 is recommended for the prevention of life-threatening hypersensitivity reactions to abacavir, a drug widely prescribed for HIV treatment. However, the implementation of screening in clinical practice is hindered by the slow turnaround time and high cost of conventional HLA genotyping methods. We have developed a biosensor platform using interdigitated electrode (IDE) functionalized with a monoclonal antibody to detect cells expressing HLA-B*57:01. This platform was evaluated using cell lines and peripheral blood mononuclear cells expressing different HLA-B alleles. The functionalized IDE sensor was able to specifically capture HLA-B*57:01 cells, resulting in a significant change in the impedance magnitude in 20 min. This IDE platform has the potential to be further developed to enable point-of-care HLA-B*57:01 screening
  • Item
    Thumbnail Image
    Development of an Ultrasensitive Impedimetric Immunosensor Platform for Detection of Plasmodium Lactate Dehydrogenase
    Low, YK ; Chan, J ; Soraya, GV ; Buffet, C ; Abeyrathne, CD ; Huynh, DH ; Skafidas, E ; Kwan, P ; Rogerson, SJ (MDPI, 2019-06-01)
    Elimination of malaria is a global health priority. Detecting an asymptomatic carrier of Plasmodium parasites to receive treatment is an important step in achieving this goal. Current available tools for detection of malaria parasites are either expensive, lacking in sensitivity for asymptomatic carriers, or low in throughput. We investigated the sensitivity of an impedimetric biosensor targeting the malaria biomarker Plasmodium lactate dehydrogenase (pLDH). Following optimization of the detection protocol, sensor performance was tested using phosphate-buffered saline (PBS), and then saliva samples spiked with pLDH at various concentrations. The presence of pLDH was determined by analyzing the sensor electrical properties before and after sample application. Through comparing percentage changes in impedance magnitude, the sensors distinguished pLDH-spiked PBS from non-spiked PBS at concentrations as low as 250 pg/mL (p = 0.0008). Percentage changes in impedance magnitude from saliva spiked with 2.5 ng/mL pLDH trended higher than those from non-spiked saliva. These results suggest that these biosensors have the potential to detect concentrations of pLDH up to two logs lower than currently available best-practice diagnostic tools. Successful optimization of this sensor platform would enable more efficient diagnosis of asymptomatic carriers, who can be targeted for treatment, contributing to the elimination of malaria.
  • Item
    Thumbnail Image
    Environmentally friendly power generator based on moving liquid dielectric and double layer effect
    Huynh, DH ; Nguyen, TC ; Nguyen, PD ; Abeyrathne, CD ; Hossain, MS ; Evans, R ; Skafidas, E (NATURE PUBLISHING GROUP, 2016-06-03)
    An electrostatic power generator converts mechanical energy to electrical energy by utilising the principle of variable capacitance. This change in capacitance is usually achieved by varying the gap or overlap between two parallel metallic plates. This paper proposes a novel electrostatic micro power generator where the change in capacitance is achieved by the movement of an aqueous solution of NaCl. A significant change in capacitance is achieved due to the higher than air dielectric constant of water and the Helmholtz double layer capacitor formed by ion separation at the electrode interfaces. The proposed device has significant advantages over traditional electrostatic devices which include low bias voltage and low mechanical frequency of operation. This is critical if the proposed device is to have utility in harvesting power from the environment. A figure of merit exceeding 10000(10(8)μW)/(mm(2)HzV(2)) which is two orders of magnitude greater than previous devices, is demonstrated for a prototype operating at a bias voltage of 1.2 V and a droplet frequency of 6 Hz. Concepts are presented for large scale power harvesting.