Electrical and Electronic Engineering - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 5 of 5
  • Item
    Thumbnail Image
    Design and Optimisation of Elliptical-Shaped Planar Hall Sensor for Biomedical Applications
    Uddin, SM ; Sayad, A ; Chan, J ; Skafidas, E ; Kwan, P (MDPI, 2022-02)
    The magnetic beads detection-based immunoassay, also called magneto-immunoassay, has potential applications in point-of-care testing (POCT) due to its unique advantage of minimal background interference from the biological sample and associated reagents. While magnetic field detection technologies are well established for numerous applications in the military, as well as in geology, archaeology, mining, spacecraft, and mobile phones, adaptation into magneto-immunoassay is yet to be explored. The magnetic field biosensors under development tend to be multilayered and require an expensive fabrication process. A low-cost and affordable biosensing platform is required for an effective point-of-care diagnosis in a resource-limited environment. Therefore, we evaluated a single-layered magnetic biosensor in this study to overcome this limitation. The shape-induced magnetic anisotropy-based planar hall effect sensor was recently developed to detect a low-level magnetic field, but was not explored for medical application. In this study, the elliptical-shaped planar hall effect (EPHE) sensor was designed, fabricated, characterized, and optimized for the magneto-immunoassay, specifically. Nine sensor variants were designed and fabricated. A customized measurement setup incorporating a lock-in amplifier was used to quantify 4.5 µm magnetic beads in a droplet. The result indicated that the single-domain behaviour of the magnetic film and larger sensing area with a thinner magnetic film had the highest sensitivity. The developed sensor was tested with a range of magnetic bead concentrations, demonstrating a limit of detection of 200 beads/μL. The sensor performance encourages employing magneto-immunoassay towards developing a low-cost POCT device in the future.
  • Item
    Thumbnail Image
    Meander Thin-Film Biosensor Fabrication to Investigate the Influence of Structural Parameters on the Magneto-Impedance Effect
    Sayad, A ; Uddin, SM ; Chan, J ; Skafidas, E ; Kwan, P (MDPI, 2021-10)
    Thin-film magneto-impedance (MI) biosensors have attracted significant attention due to their high sensitivity and easy miniaturization. However, further improvement is required to detect weak biomagnetic signals. Here, we report a meander thin-film biosensor preparation to investigate the fabrication parameters influencing the MI effect. Specifically, we hypothesized that an optimal film thickness and sensing area size ratio could be achieved to obtain a maximum MI ratio. A meander multilayer MI biosensor based on a NiFe/Cu/NiFe thin-film was designed and fabricated into 3-, 6-, and 9-turn models with film thicknesses of 3 µm and 6 µm. The 9-turn biosensor resembled the largest sensing area, while the 3- and 6-turn biosensors were designed with identical sensing areas. The results indicated that the NiFe film thickness of 6 µm with a sensing area size of 14.4 mm2 resembling a 9-turn MI biosensor is the optimal ratio yielding the maximum MI ratio of 238%, which is 70% larger than the 3- and 6-turn structures. The 3- and 6-turn MI biosensors exhibited similar characteristics where the MI ratio peaked at a similar value. Our results suggest that the MI ratio can be increased by increasing the sensing area size and film thickness rather than the number of turns. We showed that an optimal film thickness to sensing area size ratio is required to obtain a high MI ratio. Our findings will be useful for designing highly sensitive MI biosensors capable of detecting low biomagnetic signals.
  • Item
    Thumbnail Image
    Heater Integrated Lab-on-a-Chip Device for Rapid HLA Alleles Amplification towards Prevention of Drug Hypersensitivity
    Uddin, SM ; Sayad, A ; Chan, J ; Huynh, DH ; Skafidas, E ; Kwan, P (MDPI, 2021-05)
    HLA-B*15:02 screening before administering carbamazepine is recommended to prevent life-threatening hypersensitivity. However, the unavailability of a point-of-care device impedes this screening process. Our research group previously developed a two-step HLA-B*15:02 detection technique utilizing loop-mediated isothermal amplification (LAMP) on the tube, which requires two-stage device development to translate into a portable platform. Here, we report a heater-integrated lab-on-a-chip device for the LAMP amplification, which can rapidly detect HLA-B alleles colorimetrically. A gold-patterned micro-sized heater was integrated into a 3D-printed chip, allowing microfluidic pumping, valving, and incubation. The performance of the chip was tested with color dye. Then LAMP assay was conducted with human genomic DNA samples of known HLA-B genotypes in the LAMP-chip parallel with the tube assay. The LAMP-on-chip results showed a complete match with the LAMP-on-tube assay, demonstrating the detection system's concurrence.
  • Item
    Thumbnail Image
    Ultrasensitive and label-free biosensor for the detection of Plasmodium falciparum histidine-rich protein II in saliva.
    Soraya, GV ; Abeyrathne, CD ; Buffet, C ; Huynh, DH ; Uddin, SM ; Chan, J ; Skafidas, E ; Kwan, P ; Rogerson, SJ (Nature Publishing Group, 2019-11-25)
    Malaria elimination is a global public health priority. To fulfil the demands of elimination diagnostics, we have developed an interdigitated electrode sensor platform targeting the Plasmodium falciparum Histidine Rich Protein 2 (PfHRP2) protein in saliva samples. A protocol for frequency-specific PfHRP2 detection in phosphate buffered saline was developed, yielding a sensitivity of 2.5 pg/mL based on change in impedance magnitude of the sensor. This protocol was adapted and optimized for use in saliva with a sensitivity of 25 pg/mL based on change in resistance. Further validation demonstrated detection in saliva spiked with PfHRP2 from clinical isolates in 8 of 11 samples. With a turnaround time of ~2 hours, the label-free platform based on impedance sensors has the potential for miniaturization into a point-of-care diagnostic device for malaria elimination.
  • Item
    Thumbnail Image
    Rapid Detection of HLA-B*57:01-Expressing Cells Using a Label-Free Interdigitated Electrode Biosensor Platform for Prevention of Abacavir Hypersensitivity in HIV Treatment
    Chan, J ; Soraya, GV ; Craig, L ; Uddin, SM ; Todaro, M ; Huynh, DH ; Abeyrathne, CD ; Kostenko, L ; McCluskey, J ; Skafidas, E ; Kwan, P (MDPI AG, 2019-08-20)
    Pre-treatment screening of individuals for human leukocyte antigens (HLA) HLA-B*57:01 is recommended for the prevention of life-threatening hypersensitivity reactions to abacavir, a drug widely prescribed for HIV treatment. However, the implementation of screening in clinical practice is hindered by the slow turnaround time and high cost of conventional HLA genotyping methods. We have developed a biosensor platform using interdigitated electrode (IDE) functionalized with a monoclonal antibody to detect cells expressing HLA-B*57:01. This platform was evaluated using cell lines and peripheral blood mononuclear cells expressing different HLA-B alleles. The functionalized IDE sensor was able to specifically capture HLA-B*57:01 cells, resulting in a significant change in the impedance magnitude in 20 min. This IDE platform has the potential to be further developed to enable point-of-care HLA-B*57:01 screening