Ophthalmology (Eye & Ear Hospital) - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 26
  • Item
    Thumbnail Image
    Comparison of Visual Function Tests in Intermediate Age-Related Macular Degeneration
    Guymer, RH ; Tan, RS ; Luu, CD (ASSOC RESEARCH VISION OPHTHALMOLOGY INC, 2021-10)
    PURPOSE: Identifying the most sensitive functional measure in intermediate age-related macular degeneration (iAMD) could help select an appropriate test for monitoring disease progression and evaluating the efficacy of novel interventions for the early stages of AMD. The purpose of the study was to determine which commonly used visual function test is the most discriminatory when comparing individuals with iAMD to normal participants. METHODS: In this prospective observational study, iAMD cases and healthy controls underwent visual function testing (best corrected visual acuity (BCVA), low luminance visual acuity (LLVA), mesopic microperimetry, dark adaptation, and scotopic perimetry following photobleach), clinical eye examination, and multimodal retinal imaging in a single study visit. The data of each functional parameter were converted into z-score so that all the parameters had a common scale to allow a direct comparison between different functional parameters. RESULTS: Forty-eight subjects (23 normal control, 25 iAMD) participated. Although all five parameters showed a significant reduction in function in iAMD eyes compared to controls (P ≤ 0.003), the rod intercept time (RIT) detected the greatest reduction in function followed by the scotopic sensitivity, mesopic sensitivity, BCVA, and LLVA, with the absolute mean z-score of 4.5, 2.2, 1.0, 1.0, and 1.2, respectively. CONCLUSIONS: Among the five visual function parameters commonly used, RIT is the most discriminatory functional parameter in the early stages of AMD. TRANSLATIONAL RELEVANCE: The RIT could be considered for assessing visual function and evaluating efficacy of novel interventions aimed at improving retinal function in eyes with early stages of AMD.
  • Item
    Thumbnail Image
    Ellipsoid zone on optical coherence tomography: a review
    Tao, LW ; Wu, Z ; Guymer, RH ; Luu, CD (WILEY, 2016-07)
    Emergence of the high-resolution optical coherence tomography has allowed better delineation of retinal layers, and many of the anatomical correlations of these layers have now been agreed upon. However, some anatomical correlates still remain contentious, such as the second hyper-reflective band, which is now termed ellipsoid zone. Despite the lack of consensus of the actual origin of the ellipsoid zone, there has been much interest in evaluating its integrity and intensity in different disease processes. This review paper aims to provide an overview of the ellipsoid zone and its clinical and research applications.
  • Item
    Thumbnail Image
    Relationship between reticular pseudodrusen and choroidal thickness in intermediate age-related macular degeneration: response
    Ho, CYD ; Lek, JJ ; Aung, KZ ; McGuinness, MB ; Luu, CD ; Guymer, RH (WILEY, 2018-11)
  • Item
    Thumbnail Image
    Relationship between reticular pseudodrusen and choroidal thickness in intermediate age-related macular degeneration
    Ho, CYD ; Lek, JJ ; Aung, KZ ; McGuinness, MB ; Luu, CD ; Guymer, RH (WILEY, 2018-07)
    IMPORTANCE: Reticular pseudodrusen (RPD) is strongly associated with late age-related macular degeneration (AMD) but their aetiology remains unknown. RPD have been associated with reduced choroidal thickness (ChT) but most studies are limited by small sample size and varying severity of AMD. BACKGROUND: To investigate the relationship between choroidal thickness and RPD in eyes with intermediate AMD (iAMD), controlling for variables known to influence ChT. DESIGN: Retrospective cohort study. PARTICIPANTS: Participants were recruited from Centre for Eye Research Australia. METHODS: Colour fundus photographs, fundus auto fluorescence, near-infrared and spectral-domain ocular coherence tomography (OCT) were graded for RPD. ChT was measured from enhanced-depth imaging OCT scans at the centre of fovea, 1500 and 3000 μm nasal, temporal, superior and inferior from centre of fovea. MAIN OUTCOME MEASURES: ChT between RPD and non-RPD group. RESULTS: A total of 297 eyes from 152 subjects were included. A total of 84 (28%) had RPD and were older than non-RPD group (75.1 ± 5.4 years and 68.7 ± 6.9 years, respectively; P < 0.001). In unadjusted analysis, the RPD group was significantly associated with thinner choroids across all measured locations (P ≤ 0.022). After adjustment for variables, the presence of RPD was no longer associated with ChT (P ≥ 0.132 for all locations) but age (P < 0.001) and refractive error (P = 0.002) remained significantly associated with ChT. CONCLUSIONS AND RELEVANCE: Age and refractive error, rather than RPD, was significantly associated with reduced ChT in eyes with iAMD. Choroidal insufficiency may be a less important variable in RPD aetiology than previously considered.
  • Item
    Thumbnail Image
    Multi-focal electro-retinogram response following sub-threshold nano-second laser intervention in age-related macular degeneration
    Luu, CD ; Makeyeva, G ; Caruso, E ; Baglin, E ; Sivarajah, P ; Wu, Z ; Guymer, RH (WILEY, 2020-09)
    IMPORTANCE: The effect of sub-threshold nano-second laser (SNL) treatment on retinal function remains unknown. BACKGROUND: SNL treatment has been studied as a potential intervention in intermediate age-related macular degeneration (iAMD). This study investigated the longitudinal effect of SNL treatment on retinal function. DESIGN: This was a sub-study of the LEAD trial; a 36-month, multi-centre, randomized and sham-controlled trial. PARTICIPANTS: Subjects with iAMD. METHODS: Eligible participants were assigned randomly to receive SNL or sham treatment to the study eye at 6-monthly visits. Multi-focal electro-retinography (mfERG) was performed at each study visit from a study site. The mfERG responses were grouped into three regions (central, middle and outer rings) and compared between the SNL and sham group. MAIN OUTCOME MEASURES: mfERG P1 response amplitude and implicit time. RESULTS: Data were collected from 50 subjects (26 in the SNL group, 24 in the sham group). At baseline, the P1 amplitudes of both the study eyes and the fellow eyes were similar between the groups at all rings. In the sham group, the P1 amplitude gradually decreased over time (P < .05). In the SNL group, there was an improvement in P1 amplitude which became statistically significant at the 36-month visit, detected in both the treated and fellow eyes at the central (P = .005) and middle ring (P = .007) but not at the outer ring (P = .070). No difference in P1 implicit time detected between the groups (P > .05). CONCLUSIONS AND RELEVANCE: SNL treatment improved electro-physiological function. mfERG could be useful for monitoring AMD progression and evaluating the efficacy of SNL treatment.
  • Item
    Thumbnail Image
    New Technologies to Study Functional Genomics of Age-Related Macular Degeneration
    Nguyen, T ; Urrutia-Cabrera, D ; Liou, RH-C ; Luu, CD ; Guymer, R ; Wong, RC-B (FRONTIERS MEDIA SA, 2021-01-11)
    Age-related macular degeneration (AMD) is the most common cause of irreversible vision loss in people over 50 years old in developed countries. Currently, we still lack a comprehensive understanding of the genetic factors contributing to AMD, which is critical to identify effective therapeutic targets to improve treatment outcomes for AMD patients. Here we discuss the latest technologies that can facilitate the identification and functional study of putative genes in AMD pathology. We review improved genomic methods to identify novel AMD genes, advances in single cell transcriptomics to profile gene expression in specific retinal cell types, and summarize recent development of in vitro models for studying AMD using induced pluripotent stem cells, organoids and biomaterials, as well as new molecular technologies using CRISPR/Cas that could facilitate functional studies of AMD-associated genes.
  • Item
    Thumbnail Image
    Advances in implantable bionic devices for blindness: a review
    Lewis, PM ; Ayton, LN ; Guymer, RH ; Lowery, AJ ; Blamey, PJ ; Allen, PJ ; Luu, CD ; Rosenfeld, JV (WILEY, 2016-09)
    Since the 1950s, vision researchers have been working towards the ambitious goal of restoring a functional level of vision to the blind via electrical stimulation of the visual pathways. Groups based in Australia, USA, Germany, France and Japan report progress in the translation of retinal visual prosthetics from the experimental to clinical domains, with two retinal visual prostheses having recently received regulatory approval for clinical use. Regulatory approval for cortical visual prostheses is yet to be obtained; however, several groups report plans to conduct clinical trials in the near future, building upon the seminal clinical studies of Brindley and Dobelle. In this review, we discuss the general principles of visual prostheses employing electrical stimulation of the visual pathways, focusing on the retina and visual cortex as the two most extensively studied stimulation sites. We also discuss the surgical and functional outcomes reported to date for retinal and cortical prostheses, concluding with a brief discussion of novel developments in this field and an outlook for the future.
  • Item
    Thumbnail Image
    Classification of healthy and diseased retina using SD-OCT imaging and Random Forest algorithm
    Hussain, MA ; Bhuiyan, A ; Luu, CD ; Smith, RT ; Guymer, RH ; Ishikawa, H ; Schuman, JS ; Ramamohanarao, K ; Vavvas, DG (PUBLIC LIBRARY SCIENCE, 2018-06-04)
    In this paper, we propose a novel classification model for automatically identifying individuals with age-related macular degeneration (AMD) or Diabetic Macular Edema (DME) using retinal features from Spectral Domain Optical Coherence Tomography (SD-OCT) images. Our classification method uses retinal features such as the thickness of the retina and the thickness of the individual retinal layers, and the volume of the pathologies such as drusen and hyper-reflective intra-retinal spots. We extract automatically, ten clinically important retinal features by segmenting individual SD-OCT images for classification purposes. The effectiveness of the extracted features is evaluated using several classification methods such as Random Forrest on 251 (59 normal, 177 AMD and 15 DME) subjects. We have performed 15-fold cross-validation tests for three phenotypes; DME, AMD and normal cases using these data sets and achieved accuracy of more than 95% on each data set with the classification method using Random Forrest. When we trained the system as a two-class problem of normal and eye with pathology, using the Random Forrest classifier, we obtained an accuracy of more than 96%. The area under the receiver operating characteristic curve (AUC) finds a value of 0.99 for each dataset. We have also shown the performance of four state-of-the-methods for classification the eye participants and found that our proposed method showed the best accuracy.
  • Item
    Thumbnail Image
    Repeatability of Retinal Sensitivity Measurements Using a Medmont Dark-Adapted Chromatic Perimeter in Healthy and Age-Related Macular Degeneration Cases
    Tan, RS ; Guymer, RH ; Luu, CD (ASSOC RESEARCH VISION OPHTHALMOLOGY INC, 2018-05)
    PURPOSE: To determine the intrasession and intersession test-retest repeatability of retinal sensitivity measurements using a dark-adapted chromatic perimeter (DACP). METHODS: For intrasession testing, retinal sensitivity within the central 24° for the 505-nm stimulus was measured after 20, 30, and 40 minutes of dark adaptation (DA) and for the 625-nm stimulus was measured after the first and second 505-nm tests. For intersession testing, retinal sensitivity for both stimuli was measured after 30 minutes of DA at baseline and 1 month. The point-wise sensitivity (PWS) difference and coefficient of repeatability (CoR) of each stimulus and group were determined. RESULTS: For intrasession testing, 10 age-related macular degeneration (AMD) and eight control subjects were recruited. The overall CoR for the 505-nm stimulus was 8.4 dB for control subjects and 9.1 dB for AMD cases, and for the 625-nm stimulus was 6.7 dB for control subjects and 9.5 dB for AMD cases. For intersession testing, seven AMD cases and 13 control subjects returned an overall CoR for the 505-nm stimulus of 8.2 dB for the control and 11.7 dB for the AMD group. For the 625-nm stimulus the CoR was 6.2 dB for the control group and 8.4 dB for the AMD group. Approximately 80% of all test points had a PWS difference of ±5 dB between the two intrasession or intersession measurements for both stimuli. CONCLUSIONS: The CoR for the DACP is larger than that reported for scotopic perimeters; however, the majority of test points had a PWS difference of ±5 dB between tests. TRANSLATIONAL RELEVANCE: The DACP offers an opportunity to measure static and dynamic rod function at multiple locations with an acceptable reproducibility level.
  • Item
    Thumbnail Image
    Validation of an Automated Quantification of Relative Ellipsoid Zone Reflectivity on Spectral Domain-Optical Coherence Tomography Images
    Thiele, S ; Isselmann, B ; Pfau, M ; Holz, FG ; Schmitz-Valckenberg, S ; Wu, Z ; Guymer, RH ; Luu, CD (ASSOC RESEARCH VISION OPHTHALMOLOGY INC, 2020-10)
    PURPOSE: Relative ellipsoid zone reflectivity (rEZR) represents a potential biomarker of photoreceptor health on spectral-domain optical coherence tomography (SD-OCT). Because manual quantification of rEZR is laborious and lacks of spatial resolution, automated quantification of the rEZR would be beneficial. The purpose of this study was to evaluate the reliability and reproducibility of an automated rEZR quantification method. METHODS: The rEZR was acquired using a manual and an automated approach in eyes with age-related macular degeneration (AMD) and healthy controls. The rEZR obtained from both methods was compared and the agreement between the methods and their reproducibility assessed. RESULTS: Forty eyes of 40 participants with a mean (± standard deviation) age of 65.2 ± 7.8 years were included. Both the manual and automated method showed that control eyes exhibit a greater rEZR than AMD eyes (P < 0.001). Overall, the limits of agreement between the manual and automated method were -7.5 to 7.3 arbitrary units (AU) and 95% of the data points had a difference in the rEZR between the methods of ±8.2%. An expected perfect reproducibility was observed for the automated method, whereas the manual method had a coefficient of repeatability of 6.3 arbitrary units. CONCLUSIONS: The automated quantification of rEZR method is reliable and reproducible. Further studies of the rEZR as a novel biomarker for AMD severity and progression are warranted. TRANSLATIONAL RELEVANCE: Automated quantification of SD-OCT-based rEZR allows for its comprehensive and longitudinal characterization evaluating its relevance as an in vivo biomarker of photoreceptor function and its prognostic value for AMD progression.