    MYTHEN CdTe: a new generation state-of-the-art X-ray imaging detector
    Elbracht-Leong, Stefanie ( 2016)
    MYTHEN is a single photon counting hybrid strip X-ray detector that has found application in X-ray powder diffraction (XRPD) experiments at synchrotrons worldwide. Originally designed to operate with hole collecting silicon sensors, MYTHEN is suited for detecting X-rays above 5 keV. However many PD beamlines have been designed for energies above 50 keV where silicon sensors have an efficiency of only a few percent. In order to adapt MYTHEN to meet these energies, the absorption efficiency of the sensor must be substantially increased. Cadmium-telluride (CdTe) has an absorption efficiency approximately 30 times that of silicon at 50 keV, and is therefore a very promising replacement sensor material candidate. Furthermore, the large dynamic range of the pre-amplifier of MYTHEN and its capability to process charge carriers of either polarity has enabled the characterization of both electron and hole collecting CdTe sensors. A selection of Schottky and ohmic type CdTe MYTHEN test structures have undergone a series of characterization experiments including bias and settings optimization, energy calibration, count rate capability as well as stability tests of bias and radiation induced polarizations. The performance of those systems will be presented and discussed in this thesis. Both, the radiation and bias induced polarization effects remained manageable. The MYTHEN system combined with CdTe sensors has proven to be reliable and stable despite high stress experiments. When biased over an extended period of time, the results of the studies have demonstrated that overdepletion of the sensors allowed the system to remain functional for a period of time 6 fold longer. During the high radiation studies, a count rate loss as well as a shift in threshold were observed, leading to the conclusion that individual charge carriers are been trapped. When applying a high bias as well as high flux, the detector system remained functional for 30 minutes. It was also demonstrated that a brief power cycle resumed normal performance after the system had shown symptoms of either polarization effect. Overall, the polarization effects observed on MYTHEN CdTe strip detector are temporary and show a slower impact than reported in the literature. Generally, a higher bias improved the stability of the detector.