Physiotherapy - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 2 of 2
  • Item
    No Preview Available
    Weight and fat distribution in patients taking valproate: A valproate-discordant gender-matched twin and sibling pair study
    Petty, SJ ; Kantor, S ; Lawrence, KM ; Berkovic, SF ; Collins, M ; Hill, KD ; Makovey, J ; Sambrook, PN ; O'Brien, TJ ; Wark, JD (WILEY, 2014-10)
    OBJECTIVES: Chronic treatment with valproate (VPA) is commonly associated with weight gain, which potentially has important health implications, in particular increased central fat distribution. We utilized a VPA-discordant same-sex, twin and matched sibling pair study design to primarily examine for differences in fat distribution between patients with epilepsy treated with VPA compared to their matched twin or sibling control. Weight, blood pressure, and leptin levels were assessed. METHODS: Height, weight, waist and hip measurements, exercise, blood pressure (BP), and serum leptin levels were measured. Body composition was measured using dual-energy x-ray absorptiometry (DXA). Abdominal fat was expressed as a percentage of the abdominal region (AFat%); and of whole body fat (WBF); (AFat%WBF). Mean within-pair differences were assessed (VPA-user and nonuser). Restricted maximum likelihood (REML) linear mixed model analysis was fitted to examine associations of anthropometrics, zygosity, gender, menopausal status, VPA dose and duration, with weight and AFat%. RESULTS: We studied 19 pairs of VPA-discordant, gender-matched (five male, 14 female) twins and siblings. Mean (standard deviation, SD) duration of therapy for VPA users was 11.0 (7.4) years. There were no statistically significant within-pair differences in age, height, weight, body mass index (BMI), BP, leptin level, WBF, AFat%, or AFat%WBF. For pairs in which VPA-user was treated for >11 years there were statistically significant mean within-pair differences in AFat%, (+7.1%, p = 0.03, n = 10 pairs), mean BP (+11.0 mm Hg, p = 0.006, n = 8 pairs); but not in AFat%WBF. VPA duration was positively associated with weight (estimate +0.98 kg/per year of VPA, p = 0.03); VPA treatment duration and dose were not significantly associated with AFat%. SIGNIFICANCE: This study demonstrated a relationship between long-term VPA use and abdominal adiposity (AFat%), which could have significant health implications. We recommend ongoing monitoring of weight, BMI, and blood pressure for patients taking VPA.
  • Item
    No Preview Available
    Changes in balance function with chronic antiepileptic drug therapy: A twin and sibling study
    Ahmad, BS ; Wark, JD ; Petty, SJ ; O'Brien, TJ ; Gorelik, A ; Sambrook, PN ; Hill, KD (WILEY, 2015-11)
    OBJECTIVE: To investigate cross-sectional and longitudinal differences in static and dynamic standing balance measures and lower limb muscle strength in patients who are treated chronically with antiepileptic drugs (AEDs). METHODS: Twenty-six AED exposure-discordant same-gender twin and sibling pairs were studied. Clinical and laboratory balance examinations were conducted twice, separated by at least 1 year. The mean within-pair differences in balance measures were calculated cross-sectionally at baseline and follow-up, and longitudinally. RESULTS: No significant mean within-pair difference was found at baseline in age (44 years), weight, and height (p > 0.05). Between study assessments, the median (interquartile range [IQR]) interval was 3.0 (2.1-4.3) years in users and 2.9 (2.0-4.4) years in nonusers. The median duration of AED therapy was 19 (11-21) years. At baseline and follow-up, cross-sectional sway measures from posturography (Chattecx Balance System) and clinical static balance tests showed poorer performance in users compared to nonusers on several test conditions (p = 0.002-0.032). At follow-up, the users took longer than nonusers to complete the Four-Square-Step Test (p = 0.005) and Five-Times-Sit-to-Stand Test (p = 0.018). A greater annual rate of deterioration in sway was found in users compared to nonusers using posturography on the anteroposterior tilting platform task with distraction (p = 0.032). In both groups, higher baseline sway predicted greater annual deterioration in sway in all platform conditions (β = 0.3-0.5, p < 0.001-0.013). The annual change in measures did not differ between groups in the clinical balance and lower limb strength assessments. SIGNIFICANCE: In this longitudinal twin and sibling study, chronic AED users had poorer standing balance compared to nonusers. Users showed greater deterioration in postural sway with one dynamic platform condition. AEDs may progressively impair balance mechanisms, although this requires further investigations. Repeated dynamic posturography could provide a basis for preventive trials for maintaining or improving balance.