Biomedical Engineering - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 5 of 5
  • Item
    Thumbnail Image
    Subject-specific musculoskeletal modeling in the evaluation of shoulder muscle and joint function
    Wu, W ; Lee, PVS ; Bryant, AL ; Galea, M ; Ackland, DC (ELSEVIER SCI LTD, 2016-11-07)
    Upper limb muscle force estimation using Hill-type muscle models depends on musculotendon parameter values, which cannot be readily measured non-invasively. Generic and scaled-generic parameters may be quickly and easily employed, but these approaches do not account for an individual subject's joint torque capacity. The objective of the present study was to develop a subject-specific experimental testing and modeling framework to evaluate shoulder muscle and joint function during activities of daily living, and to assess the capacity of generic and scaled-generic musculotendon parameters to predict muscle and joint function. Three-dimensional musculoskeletal models of the shoulders of 6 healthy subjects were developed to calculate muscle and glenohumeral joint loading during abduction, flexion, horizontal flexion, nose touching and reaching using subject-specific, scaled-generic and generic musculotendon parameters. Muscle and glenohumeral joint forces calculated using generic and scaled-generic models were significantly different to those of subject-specific models (p<0.05), and task dependent; however, scaled-generic model calculations of shoulder glenohumeral joint force demonstrated better agreement with those of subject-specific models during abduction and flexion. Muscles in generic musculoskeletal models operated further from the plateau of their force-length curves than those of scaled-generic and subject-specific models, while muscles in subject-specific models operated over a wider region of their force length curves than those of the generic or scaled-generic models, reflecting diversity of subject shoulder strength. The findings of this study suggest that generic and scaled-generic musculotendon parameters may not provide sufficient accuracy in prediction of shoulder muscle and joint loading when compared to models that employ subject-specific parameter-estimation approaches.
  • Item
    Thumbnail Image
    Microstructure Variations in the Soft-Hard Tissue Junction of the Human Anterior Cruciate Ligament
    Zhao, L ; Lee, PVS ; Ackland, DC ; Broom, ND ; Thambyah, A (WILEY, 2017-09)
  • Item
    Thumbnail Image
    The influence of rotator cuff tears on muscle and joint-contact loading after reverse total shoulder arthroplasty
    Ackland, DC ; Robinson, DL ; Wilkosz, A ; Wu, W ; Richardson, M ; Lee, P ; Tse, KM (WILEY, 2019-01)
  • Item
    Thumbnail Image
    Load response of the natural tooth and dental implant: A comparative biomechanics study
    Robinson, D ; Aguilar, L ; Gatti, A ; Abduo, J ; Lee, PVS ; Ackland, D (The Korean Academy of Prosthodontics, 2019-06-26)
    While dental implants have displayed high success rates, poor mechanical fixation is a common complication, and their biomechanical response to occlusal loading remains poorly understood. This study aimed to develop and validate a computational model of a natural first premolar and a dental implant with matching crown morphology, and quantify their mechanical response to loading at the occlusal surface. A finite-element model of the stomatognathic system comprising the mandible, first premolar and periodontal ligament (PDL) was developed based on a natural human tooth, and a model of a dental implant of identical occlusal geometry was also created. Occlusal loading was simulated using point forces applied at seven landmarks on each crown. Model predictions were validated using strain gauge measurements acquired during loading of matched physical models of the tooth and implant assemblies. For the natural tooth, the maximum vonMises stress (6.4 MPa) and maximal principal strains at the mandible (1.8 mε, −1.7 mε) were lower than those observed at the prosthetic tooth (12.5 MPa, 3.2 mε, and −4.4 mε, respectively). As occlusal load was applied more bucally relative to the tooth central axis, stress and strain magnitudes increased. Occlusal loading of the natural tooth results in lower stress-strain magnitudes in the underlying alveolar bone than those associated with a dental implant of matched occlusal anatomy. The PDL may function to mitigate axial and bending stress intensities resulting from off-centered occlusal loads. The findings may be useful in dental implant design, restoration material selection, and surgical planning.
  • Item
    Thumbnail Image
    Cortical and Trabecular Bone Fracture Characterisation in the Vertebral Body Using Acoustic Emission
    Robinson, DL ; Tse, KM ; Franklyn, M ; Zhang, JY ; Ackland, D ; Lee, PVS (SPRINGER, 2019-12)
    The ability to rapidly detect localised fractures of cortical and/or trabecular bone sustained by the vertebral body would enhance the analysis of vertebral fracture initiation and propagation during dynamic loading. In this study, high rate axial compression tests were performed on twenty sets of three-vertebra lumbar spine specimens. Acoustic Emission (AE) sensor measurements of sound wave pressure were used to classify isolated trabecular fractures and severe compressive fractures of vertebral body cortical and trabecular bone. Fracture detection using standard AE parameters was compared to that of traditional mechanical parameters obtained from load cell and displacement readings. Results indicated that the AE parameters achieved slightly enhanced classification of isolated trabecular fractures, whereas the mechanical parameters better identified combined fractures of cortical and trabecular bone. These findings demonstrate that AE may be used to promptly and accurately identify localised fractures of trabecular bone, whereas more extensive fractures of the vertebral body are best identified by load cell readings due to the considerable loss in compressive resistance. The discrimination thresholds corresponding to the AE parameters were based on calibrated measurements of AE wave pressure and may ultimately be used to examine the onset and progression of vertebral fracture in other loading scenarios.