Biomedical Engineering - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 3 of 3
  • Item
    No Preview Available
    Establishing the Calibration Curve of a Compressive Ophthalmodynamometry Device
    Kaplan, MA ; Bui, B ; Ayton, LN ; Bao, N ; Grayden, DB ; John, S (IEEE, 2023)
    The relationship between externally applied force and intraocular pressure was determined using an ex-vivo porcine eye model (N=9). Eyes were indented through the sclera with a convex ophthalmodynamometry head (ODM). Intraocular pressure and ophthalmodynamometric force were simultaneously recorded to establish a calibration curve of this indenter head. A calibration coefficient of 0.140 ± 0.009 mmHg/mN was established and was shown to be highly linear (r = 0.998 ± 0.002). Repeat application of ODM resulted in a 0.010 ± 0.002 mmHg/mN increase to the calibration coefficient.Clinical Relevance- ODM has been highlighted as a potential method of non-invasively estimating intracranial pressure. This study provides relevant data for the practical performance of ODM with similar compressive devices.
  • Item
    No Preview Available
    Non-Invasive Measurement of Intracranial Pressure Through Application of Venous Ophthalmodynamometry.
    Lo, L ; Zhao, D ; Ayton, L ; Grayden, D ; Bui, B ; Morokoff, A ; John, S (IEEE, 2021-11)
    Non-invasive intracranial pressure (ICP) monitoring is possible using venous ophthalmodynamometry to observe a pulsation in retinal blood vessels when intraocular pressure (IOP) exceeds ICP. Here, we identify features in the eye - optic disc and retinal blood vessel locations - and identify pulsation in large retinal blood vessels. The relationship between force and the magnitude of pulsation is used to estimate ICP when force is applied to the eye to gradually increase IOP over time. This approach yields 77% accuracy in automatically observing vessel pulsation.Clinical Relevance - Non-invasive ICP monitoring is desirable to improve patient outcome by reducing potential trauma and complications associated with invasive assessment with intracranial sensors or lumbar puncture.
  • Item
    Thumbnail Image
    White matter tract conductivity is resistant to wide variations in paranodal structure and myelin thickness accompanying the loss of Tyro3: an experimental and simulated analysis
    Blades, F ; Chambers, JD ; Aumann, TD ; Nguyen, CTO ; Wong, VHY ; Aprico, A ; Nwoke, EC ; Bui, B ; Grayden, DB ; Kilpatrick, TJ ; Binder, MD (SPRINGER HEIDELBERG, 2022-07)
    Myelination within the central nervous system (CNS) is crucial for the conduction of action potentials by neurons. Variation in compact myelin morphology and the structure of the paranode are hypothesised to have significant impact on the speed of action potentials. There are, however, limited experimental data investigating the impact of changes in myelin structure upon conductivity in the central nervous system. We have used a genetic model in which myelin thickness is reduced to investigate the effect of myelin alterations upon action potential velocity. A detailed examination of the myelin ultrastructure of mice in which the receptor tyrosine kinase Tyro3 has been deleted showed that, in addition to thinner myelin, these mice have significantly disrupted paranodes. Despite these alterations to myelin and paranodal structure, we did not identify a reduction in conductivity in either the corpus callosum or the optic nerve. Exploration of these results using a mathematical model of neuronal conductivity predicts that the absence of Tyro3 would lead to reduced conductivity in single fibres, but would not affect the compound action potential of multiple myelinated neurons as seen in neuronal tracts. Our data highlight the importance of experimental assessment of conductivity and suggests that simple assessment of structural changes to myelin is a poor predictor of neural functional outcomes.