- Biomedical Engineering - Research Publications
Biomedical Engineering - Research Publications
Permanent URI for this collection
73 results
Filters
Reset filtersSettings
Statistics
Citations
Search Results
Now showing
1 - 10 of 73
-
ItemFrequency set selection for multi-frequency steady-state visual evoked potential-based brain-computer interfacesMu, J ; Grayden, DBB ; Tan, Y ; Oetomo, D (FRONTIERS MEDIA SA, 2022-12-21)OBJECTIVE: Multi-frequency steady-state visual evoked potential (SSVEP) stimulation and decoding methods enable the representation of a large number of visual targets in brain-computer interfaces (BCIs). However, unlike traditional single-frequency SSVEP, multi-frequency SSVEP is not yet widely used. One of the key reasons is that the redundancy in the input options requires an additional selection process to define an effective set of frequencies for the interface. This study investigates systematic frequency set selection methods. METHODS: An optimization strategy based on the analysis of the frequency components in the resulting multi-frequency SSVEP is proposed, investigated and compared to existing methods, which are constructed based on the analysis of the stimulation (input) signals. We hypothesized that minimizing the occurrence of common sums in the multi-frequency SSVEP improves the performance of the interface, and that selection by pairs further increases the accuracy compared to selection by frequencies. An experiment with 12 participants was conducted to validate the hypotheses. RESULTS: Our results demonstrated a statistically significant improvement in decoding accuracy with the proposed optimization strategy based on multi-frequency SSVEP features compared to conventional techniques. Both hypotheses were validated by the experiments. CONCLUSION: Performing selection by pairs and minimizing the number of common sums in selection by pairs are effective ways to select suitable frequency sets that improve multi-frequency SSVEP-based BCI accuracies. SIGNIFICANCE: This study provides guidance on frequency set selection in multi-frequency SSVEP. The proposed method in this study shows significant improvement in BCI performance (decoding accuracy) compared to existing methods in the literature.
-
ItemNo Preview AvailableElectrochemistry in a Two- or Three-Electrode Configuration to Understand Monopolar or Bipolar Configurations of Platinum Bionic ImplantsHarris, AR ; Grayden, DB ; John, SE (MDPI, 2023-04)Electrodes are used in vivo for chemical sensing, electrophysiological recording, and stimulation of tissue. The electrode configuration used in vivo is often optimised for a specific anatomy and biological or clinical outcomes, not electrochemical performance. Electrode materials and geometries are constrained by biostability and biocompatibility issues and may be required to function clinically for decades. We performed benchtop electrochemistry, with changes in reference electrode, smaller counter-electrode sizes, and three- or two-electrode configurations. We detail the effects different electrode configurations have on typical electroanalytical techniques used on implanted electrodes. Changes in reference electrode required correction by application of an offset potential. In a two-electrode configuration with similar working and reference/counter-electrode sizes, the electrochemical response was dictated by the rate-limiting charge transfer step at either electrode. This could invalidate calibration curves, standard analytical methods, and equations, and prevent use of commercial simulation software. We provide methods for determining if an electrode configuration is affecting the in vivo electrochemical response. We recommend sufficient details be provided in experimental sections on electronics, electrode configuration, and their calibration to justify results and discussion. In conclusion, the experimental limitations of performing in vivo electrochemistry may dictate what types of measurements and analyses are possible, such as obtaining relative rather than absolute measurements.
-
ItemNo Preview AvailableEvidence of Onset and Sustained Neural Responses to Isolated Phonemes from Intracranial Recordings in a Voice-based Cursor Control TaskMeng, K ; Lee, S-H ; Goodarzy, F ; Vogrin, S ; Cook, MJ ; Lee, S-W ; Grayden, DB (ISCA-INT SPEECH COMMUNICATION ASSOC, 2022-01-01)
-
ItemNo Preview AvailableImplementation of a closed-loop BCI system for real-time speech synthesis under clinical constraintsMeng, K ; Kim, E ; Vogrin, S ; Cook, MJ ; Goodarzy, F ; Grayden, DB ; Chung, CK (IEEE, 2022-01-01)
-
ItemNo Preview AvailableSleep and seizure risk in epilepsy: bed and wake times are more important than sleep durationStirling, RE ; Hidajat, CM ; Grayden, DB ; D'Souza, WJ ; Naim-Feil, J ; Dell, KL ; Schneider, LD ; Nurse, E ; Freestone, D ; Cook, MJ ; Karoly, PJ (OXFORD UNIV PRESS, 2023-07-03)Sleep duration, sleep deprivation and the sleep-wake cycle are thought to play an important role in the generation of epileptic activity and may also influence seizure risk. Hence, people diagnosed with epilepsy are commonly asked to maintain consistent sleep routines. However, emerging evidence paints a more nuanced picture of the relationship between seizures and sleep, with bidirectional effects between changes in sleep and seizure risk in addition to modulation by sleep stages and transitions between stages. We conducted a longitudinal study investigating sleep parameters and self-reported seizure occurrence in an ambulatory at-home setting using mobile and wearable monitoring. Sixty subjects wore a Fitbit smartwatch for at least 28 days while reporting their seizure activity in a mobile app. Multiple sleep features were investigated, including duration, oversleep and undersleep, and sleep onset and offset times. Sleep features in participants with epilepsy were compared to a large (n = 37 921) representative population of Fitbit users, each with 28 days of data. For participants with at least 10 seizure days (n = 34), sleep features were analysed for significant changes prior to seizure days. A total of 4956 reported seizures (mean = 83, standard deviation = 130) and 30 485 recorded sleep nights (mean = 508, standard deviation = 445) were included in the study. There was a trend for participants with epilepsy to sleep longer than the general population, although this difference was not significant. Just 5 of 34 participants showed a significant difference in sleep duration the night before seizure days compared to seizure-free days. However, 14 of 34 subjects showed significant differences between their sleep onset (bed) and/or offset (wake) times before seizure occurrence. In contrast to previous studies, the current study found undersleeping was associated with a marginal 2% decrease in seizure risk in the following 48 h (P < 0.01). Nocturnal seizures were associated with both significantly longer sleep durations and increased risk of a seizure occurring in the following 48 h. Overall, the presented results demonstrated that day-to-day changes in sleep duration had a minimal effect on reported seizures, while patient-specific changes in bed and wake times were more important for identifying seizure risk the following day. Nocturnal seizures were the only factor that significantly increased the risk of seizures in the following 48 h on a group level. Wearables can be used to identify these sleep-seizure relationships and guide clinical recommendations or improve seizure forecasting algorithms.
-
ItemNo Preview AvailableBrain model state space reconstruction using an LSTM neural networkLiu, Y ; Soto-Breceda, A ; Karoly, P ; Grayden, DB ; Zhao, Y ; Cook, MJ ; Schmidt, D ; Kuhlmann, L (IOP Publishing Ltd, 2023-06-01)Objective. Kalman filtering has previously been applied to track neural model states and parameters, particularly at the scale relevant to electroencephalography (EEG). However, this approach lacks a reliable method to determine the initial filter conditions and assumes that the distribution of states remains Gaussian. This study presents an alternative, data-driven method to track the states and parameters of neural mass models (NMMs) from EEG recordings using deep learning techniques, specifically a long short-term memory (LSTM) neural network.Approach. An LSTM filter was trained on simulated EEG data generated by a NMM using a wide range of parameters. With an appropriately customised loss function, the LSTM filter can learn the behaviour of NMMs. As a result, it can output the state vector and parameters of NMMs given observation data as the input.Main results. Test results using simulated data yielded correlations withRsquared of around 0.99 and verified that the method is robust to noise and can be more accurate than a nonlinear Kalman filter when the initial conditions of the Kalman filter are not accurate. As an example of real-world application, the LSTM filter was also applied to real EEG data that included epileptic seizures, and revealed changes in connectivity strength parameters at the beginnings of seizures.Significance. Tracking the state vector and parameters of mathematical brain models is of great importance in the area of brain modelling, monitoring, imaging and control. This approach has no need to specify the initial state vector and parameters, which is very difficult to do in practice because many of the variables being estimated cannot be measured directly in physiological experiments. This method may be applied using any NMM and, therefore, provides a general, novel, efficient approach to estimate brain model variables that are often difficult to measure.
-
ItemNo Preview AvailableComputational modeling of endovascular peripheral nerve stimulation using a stent-mounted electrode arrayLiu, JY ; Grayden, DB ; Keast, JR ; John, SE (IOP Publishing Ltd, 2023-06-01)Objective.Endovascular neuromodulation has attracted substantial interest in recent years as a minimally invasive approach to treat neurological disorders. In this study, we investigated with a computational model the feasibility of stimulating peripheral nerves with an endovascular stent-mounted electrode array.Approach.Anatomically realistic FEM models were constructed for the pudendal and vagal neurovascular bundles. The electromagnetic fields generated from electrical stimuli were computed using Sim4Life NEURON models to predict dynamic axonal responses.Main results.The models predict that the stimulation thresholds of the endovascular stent-electrode array configurations tested are comparable to that of ring electrodes and are dependent on the inter-electrode distance and orientation of the device. Arranging multiple electrodes along the longitudinal axis of the nerve lowers surface charge density without sacrificing axon recruitment, whereas arranging electrodes along the circumference of the blood vessel reduces the risk of misalignment but lowers axon recruitment.Significance.Overall, this study predicts that the endovascular stent-electrode array is a feasible stimulation option for peripheral nerves, and the electrode array can be flexibly optimized to achieve the lowest stimulation threshold.
-
ItemNo Preview AvailableVascular remodeling in sheep implanted with endovascular neural interfaceJohn, SE ; Donegan, S ; Scordas, TC ; Qi, W ; Sharma, P ; Liyanage, K ; Wilson, S ; Birchall, I ; Ooi, A ; Oxley, TJ ; May, CN ; Grayden, DB ; Opie, NL (IOP Publishing Ltd, 2022-10-01)Objective.The aim of this work was to assess vascular remodeling after the placement of an endovascular neural interface (ENI) in the superior sagittal sinus (SSS) of sheep. We also assessed the efficacy of neural recording using an ENI.Approach.The study used histological analysis to assess the composition of the foreign body response. Micro-CT images were analyzed to assess the profiles of the foreign body response and create a model of a blood vessel. Computational fluid dynamic modeling was performed on a reconstructed blood vessel to evaluate the blood flow within the vessel. Recording of brain activity in sheep was used to evaluate efficacy of neural recordings.Main results.Histological analysis showed accumulated extracellular matrix material in and around the implanted ENI. The extracellular matrix contained numerous macrophages, foreign body giant cells, and new vascular channels lined by endothelium. Image analysis of CT slices demonstrated an uneven narrowing of the SSS lumen proportional to the stent material within the blood vessel. However, the foreign body response did not occlude blood flow. The ENI was able to record epileptiform spiking activity with distinct spike morphologies.Significance. This is the first study to show high-resolution tissue profiles, the histological response to an implanted ENI and blood flow dynamic modeling based on blood vessels implanted with an ENI. The results from this study can be used to guide surgical planning and future ENI designs; stent oversizing parameters to blood vessel diameter should be considered to minimize detrimental vascular remodeling.
-
ItemNo Preview AvailableAuditory nerve responses to combined optogenetic and electrical stimulation in chronically deaf miceAjay, EA ; Trang, EP ; Thompson, AC ; Wise, AK ; Grayden, DB ; Fallon, JB ; Richardson, RT (IOP Publishing Ltd, 2023-04-01)Objective. Optogenetic stimulation of the auditory nerve offers the ability to overcome the limitations of cochlear implants through spatially precise stimulation, but cannot achieve the temporal precision nor temporal fidelity required for good hearing outcomes. Auditory midbrain recordings have indicated a combined (hybrid) stimulation approach may permit improvements in the temporal precision without sacrificing spatial precision by facilitating electrical activation thresholds. However, previous research has been conducted in undeafened or acutely deafened animal models, and the impact of chronic deafness remains unclear. Our study aims to compare the temporal precision of auditory nerve responses to optogenetic, electrical, and combined stimulation in acutely and chronically deafened animals.Methods. We directly compare the temporal fidelity (measured as percentage of elicited responses) and precision (i.e. stability of response size and timing) of electrical, optogenetic, and hybrid stimulation (varying sub-threshold or supra-threshold optogenetic power levels combined with electrical stimuli) through compound action potential and single-unit recordings of the auditory nerve in transgenic mice expressing the opsin ChR2-H134R in auditory neurons. Recordings were conducted immediately or 2-3 weeks following aminoglycoside deafening when there was evidence of auditory nerve degeneration.Main results. Results showed that responses to electrical stimulation had significantly greater temporal precision than optogenetic stimulation (p< 0.001 for measures of response size and timing). This temporal precision could be maintained with hybrid stimulation, but only when the optogenetic stimulation power used was below or near activation threshold and worsened with increasing optical power. Chronically deafened mice showed poorer facilitation of electrical activation thresholds with concurrent optogenetic stimulation than acutely deafened mice. Additionally, responses in chronically deafened mice showed poorer temporal fidelity, but improved temporal precision to optogenetic and hybrid stimulation compared to acutely deafened mice.Significance. These findings show that the improvement to temporal fidelity and temporal precision provided by a hybrid stimulation paradigm can also be achieved in chronically deafened animals, albeit at higher levels of concurrent optogenetic stimulation levels.
-
ItemNo Preview AvailableQuantifying visual acuity for pre-clinical testing of visual prosthesesSpencer, M ; Kameneva, T ; Grayden, DB ; Burkitt, AN ; Meffin, H (IOP Publishing Ltd, 2023-02-01)Objective.Visual prostheses currently restore only limited vision. More research and pre-clinical work are required to improve the devices and stimulation strategies that are used to induce neural activity that results in visual perception. Evaluation of candidate strategies and devices requires an objective way to convert measured and modelled patterns of neural activity into a quantitative measure of visual acuity.Approach.This study presents an approach that compares evoked patterns of neural activation with target and reference patterns. A d-prime measure of discriminability determines whether the evoked neural activation pattern is sufficient to discriminate between the target and reference patterns and thus provides a quantified level of visual perception in the clinical Snellen and MAR scales. The magnitude of the resulting value was demonstrated using scaled standardized 'C' and 'E' optotypes.Main results.The approach was used to assess the visual acuity provided by two alternative stimulation strategies applied to simulated retinal implants with different electrode pitch configurations and differently sized spreads of neural activity. It was found that when there is substantial overlap in neural activity generated by different electrodes, an estimate of acuity based only upon electrode pitch is incorrect; our proposed method gives an accurate result in both circumstances.Significance.Quantification of visual acuity using this approach in pre-clinical development will allow for more rapid and accurate prototyping of improved devices and neural stimulation strategies.