Biomedical Engineering - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 2 of 2
  • Item
    Thumbnail Image
    Slow-Fast Duffing Neural Mass Model
    Jafarian, A ; Freestone, DR ; Nesic, D ; Grayden, D (IEEE, 2019)
    Epileptic seizures may be initiated by random neuronal fluctuations and/or by pathological slow regulatory dynamics of ion currents. This paper presents extensions to the Jansen and Rit neural mass model (JRNMM) to replicate paroxysmal transitions in intracranial electroencephalogram (iEEG) recordings. First, the Duffing NMM (DNMM) is introduced to emulate stochastic generators of seizures. The DNMM is constructed by applying perturbations to linear models of synaptic transmission in each neural population of the JRNMM. Then, the slow-fast DNMM is introduced by considering slow dynamics (relative to membrane potential and firing rate) of some internal parameters of the DNMM to replicate pathological evolution of ion currents. Through simulation, it is illustrated that the slow-fast DNMM exhibits transitions to and from seizures with etiologies that are linked either to random input fluctuations or pathological evolution of slow states. Estimation and optimization of a log likelihood function (LLF) using a continuous-discrete unscented Kalman filter (CD-UKF) and a genetic algorithm (GA) are performed to capture dynamics of iEEG data with paroxysmal transitions.
  • Item
    No Preview Available
    Feasibility of a Chronic, Minimally Invasive Endovascular Neural Interface
    Opie, NL ; Rind, GS ; John, SE ; Ronayne, SM ; Grayden, DB ; Burkitt, AN ; May, CN ; O'Brien, TJ ; Oxley, TJ ; Patton, J ; Barbieri, R ; Ji, J ; Jabbari, E ; Dokos, S ; Mukkamala, R ; Guiraud, D ; Jovanov, E ; Dhaher, Y ; Panescu, D ; Vangils, M ; Wheeler, B ; Dhawan, AP (IEEE, 2016)
    Development of a neural interface that can be implanted without risky, open brain surgery will increase the safety and viability of chronic neural recording arrays. We have developed a minimally invasive surgical procedure and an endovascular electrode-array that can be delivered to overlie the cortex through blood vessels. Here, we describe feasibility of the endovascular interface through electrode viability, recording potential and safety. Electrochemical impedance spectroscopy demonstrated that electrode impedance was stable over 91 days and low frequency phase could be used to infer electrode incorporation into the vessel wall. Baseline neural recording were used to identify the maximum bandwidth of the neural interface, which remained stable around 193 Hz for six months. Cross-sectional areas of the implanted vessels were non-destructively measured using the Australian Synchrotron. There was no case of occlusion observed in any of the implanted animals. This work demonstrates the feasibility of an endovascular neural interface to safely and efficaciously record neural information over a chronic time course.