Surgery (St Vincent's) - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 3 of 3
  • Item
    Thumbnail Image
    Static force dependency of bone conduction transducer as sensory feedback for stump-socket based prosthesis
    Mayer, RM ; Mohammadi, A ; Alici, G ; Choong, P ; Oetomo, D (Australian Robotics and Automation Association, 2018-01-01)
    The dependency of a novel sensory feedback for stump-socket based prosthesis on the static force is presented using a bone conduction transducer as feedback source. The stimulation was induced onto the bony landmarks of the elbow, specifically the Ulna and presented in an interval halving method. The perception threshold in the range of tactile and auditory perception at three different force levels has been tested. The inter subject variability is bigger than the intra subject variation. The small static force variation suggests a similar approach as in bone conduction hearing aids and therefore a static force bigger than 6N should be applied to perceive a constant stimulation. A mechanical design to include such a novel feedback into a stump-socket needs to account for this requirement. The inter subject variability needs to be addressed by incorporate some kind of person to person calibration of the gain.
  • Item
    Thumbnail Image
    Psychometric Evaluation of Multi-Point Bone-Conducted Tactile Stimulation on the Three Bony Landmarks of the Elbow
    Mayer, RM ; Mohammadi, A ; Tan, Y ; Alici, G ; Choong, P ; Oetomo, D (IEEE, 2020)
    Sensory feedback is highly desirable in upper limb prostheses as well as in human robot interaction and other human machine interfaces. Bone conduction as sensory feedback interface is a recently studied approach showing promising properties. A combination of different feedback information is often necessary for prosthetic grasping, thus multiple feedback channels are required for effective sensory feedback. The use of multiple bone conduction stimulation sites simultaneously has not yet been studied. In this paper, the psychometric evaluation of multiple stimulation sites on the physiologically given bony landmarks on the elbow is investigated. The proposed approach is evaluated on human-subject experiments with six able-bodied subjects and one subject with transradial amputation. Vibrotactile transducers are placed on the bony landmarks of the elbow to determine the identification rate of each stimulation point separately as well as the identification rate of the number of active stimulation points for different frequencies. The outcomes show high identification rates for a frequency range from 100 to 750 Hz whilst performance deteriorates to at chance level at higher frequencies. A decreasing performance in identifying the number of active stimulation sites for an increasing number of simultaneous active transducers was observed. The obtained good performance in location identification suggests that information can be encoded via the location of the stimulation.
  • Item
    Thumbnail Image
    Tactile Feedback in Closed-Loop Control of Myoelectric Hand Grasping: Conveying Information of Multiple Sensors Simultaneously via a Single Feedback Channel.
    Mayer, RM ; Garcia-Rosas, R ; Mohammadi, A ; Tan, Y ; Alici, G ; Choong, P ; Oetomo, D (Frontiers Research Foundation, 2020-04-27)
    The appropriate sensory information feedback is important for the success of an object grasping and manipulation task. In many scenarios, the need arises for multiple feedback information to be conveyed to a prosthetic hand user simultaneously. The multiple sets of information may either (1) directly contribute to the performance of the grasping or object manipulation task, such as the feedback of the grasping force, or (2) simply form additional independent set(s) of information. In this paper, the efficacy of simultaneously conveying two independent sets of sensor information (the grasp force and a secondary set of information) through a single channel of feedback stimulation (vibrotactile via bone conduction) to the human user in a prosthetic application is investigated. The performance of the grasping task is not dependent to the second set of information in this study. Subject performance in two tasks: regulating the grasp force and identifying the secondary information, were evaluated when provided with either one corresponding information or both sets of feedback information. Visual feedback is involved in the training stage. The proposed approach is validated on human-subject experiments using a vibrotactile transducer worn on the elbow bony landmark (to realize a non-invasive bone conduction interface) carried out in a virtual reality environment to perform a closed-loop object grasping task. The experimental results show that the performance of the human subjects on either task, whilst perceiving two sets of sensory information, is not inferior to that when receiving only one set of corresponding sensory information, demonstrating the potential of conveying a second set of information through a bone conduction interface in an upper limb prosthetic task.