Surgery (St Vincent's) - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 6 of 6
  • Item
    Thumbnail Image
    Engineering transplantable human lymphatic and blood capillary networks in a porous scaffold
    Kong, AM ; Lim, SY ; Palmer, JA ; Rixon, A ; Gerrand, Y-W ; Yap, KK ; Morrison, WA ; Mitchell, GM (SAGE PUBLICATIONS INC, 2022-12)
    Due to a relative paucity of studies on human lymphatic assembly in vitro and subsequent in vivo transplantation, capillary formation and survival of primary human lymphatic (hLEC) and blood endothelial cells (hBEC) ± primary human vascular smooth muscle cells (hvSMC) were evaluated and compared in vitro and in vivo. hLEC ± hvSMC or hBEC ± hvSMC were seeded in a 3D porous scaffold in vitro, and capillary percent vascular volume (PVV) and vascular density (VD)/mm2 assessed. Scaffolds were also transplanted into a sub-cutaneous rat wound with morphology/morphometry assessment. Initially hBEC formed a larger vessel network in vitro than hLEC, with interconnected capillaries evident at 2 days. Interconnected lymphatic capillaries were slower (3 days) to assemble. hLEC capillaries demonstrated a significant overall increase in PVV (p = 0.0083) and VD (p = 0.0039) in vitro when co-cultured with hvSMC. A similar increase did not occur for hBEC + hvSMC in vitro, but hBEC + hvSMC in vivo significantly increased PVV (p = 0.0035) and VD (p = 0.0087). Morphology/morphometry established that hLEC vessels maintained distinct cell markers, and demonstrated significantly increased individual vessel and network size, and longer survival than hBEC capillaries in vivo, and established inosculation with rat lymphatics, with evidence of lymphatic function. The porous polyurethane scaffold provided advantages to capillary network formation due to its large (300-600 μm diameter) interconnected pores, and sufficient stability to ensure successful surgical transplantation in vivo. Given their successful survival and function in vivo within the porous scaffold, in vitro assembled hLEC networks using this method are potentially applicable to clinical scenarios requiring replacement of dysfunctional or absent lymphatic networks.
  • Item
    Thumbnail Image
    Hypoxic preconditioning of myoblasts implanted in a tissue engineering chamber significantly increases local angiogenesis via upregulation of myoblast vascular endothelial growth factor-A expression and downregulation of miRNA-1, miRNA-206 and angiopoietin-1
    Taylor, CJ ; Church, JE ; Williams, MD ; Gerrand, Y-W ; Keramidaris, E ; Palmer, JA ; Galea, LA ; Penington, AJ ; Morrison, WA ; Mitchell, GM (WILEY, 2018-01)
    Vascularization is a major hurdle for growing three-dimensional tissue engineered constructs. This study investigated the mechanisms involved in hypoxic preconditioning of primary rat myoblasts in vitro and their influence on local angiogenesis postimplantation. Primary rat myoblast cultures were exposed to 90 min hypoxia at <1% oxygen followed by normoxia for 24 h. Real time (RT) polymerase chain reaction evaluation indicated that 90 min hypoxia resulted in significant downregulation of miR-1 and miR-206 (p < 0.05) and angiopoietin-1 (p < 0.05) with upregulation of vascular endothelial growth factor-A (VEGF-A; p < 0.05). The miR-1 and angiopoietin-1 responses remained significantly downregulated after a 24 h rest phase. In addition, direct inhibition of miR-206 in L6 myoblasts caused a significant increase in VEGF-A expression (p < 0.05), further establishing that changes in VEGF-A expression are influenced by miR-206. Of the myogenic genes examined, MyoD was significantly upregulated, only after 24 h rest (p < 0.05). Preconditioned or control myoblasts were implanted with Matrigel™ into isolated bilateral tissue engineering chambers incorporating a flow-through epigastric vascular pedicle in severe combined immunodeficiency mice and the chamber tissue harvested 14 days later. Chambers implanted with preconditioned myoblasts had a significantly increased percentage volume of blood vessels (p = 0.0325) compared with chambers implanted with control myoblasts. Hypoxic preconditioned myoblasts promote vascularization of constructs via VEGF upregulation and downregulation of angiopoietin-1, miR-1 and miR-206. The relatively simple strategy of hypoxic preconditioning of implanted cells - including non-stem cell types - has broad, future applications in tissue engineering of skeletal muscle and other tissues, as a technique to significantly increase implant site angiogenesis.
  • Item
    Thumbnail Image
    Vascular Pedicle and Microchannels: Simple Methods Toward Effective In Vivo Vascularization of 3D Scaffolds
    Rnjak-Kovacina, J ; Gerrand, Y-W ; Wray, LS ; Tan, B ; Joukhdar, H ; Kaplan, DL ; Morrison, WA ; Mitchell, GM (WILEY, 2019-11-12)
    Poor vascularization remains a key limiting factor in translating advances in tissue engineering to clinical applications. Vascular pedicles (large arteries and veins) isolated in plastic chambers are known to sprout an extensive capillary network. This study examined the effect vascular pedicles and scaffold architecture have on vascularization and tissue integration of implanted silk scaffolds. Porous silk scaffolds with or without microchannels are manufactured to support implantation of a central vascular pedicle, without a chamber, implanted in the groin of Sprague Dawley rats, and assessed morphologically and morphometrically at 2 and 6 weeks. At both time points, blood vessels, connective tissue, and an inflammatory response infiltrate all scaffold pores externally, and centrally when a vascular pedicle is implanted. At week 2, vascular pedicles significantly increase the degree of scaffold tissue infiltration, and both the pedicle and the scaffold microchannels significantly increase vascular volume and vascular density. Interestingly, microchannels contribute to increased scaffold vascularity without affecting overall tissue infiltration, suggesting a direct effect of biomaterial architecture on vascularization. The inclusion of pedicles and microchannels are simple and effective proangiogenic techniques for engineering thick tissue constructs as both increase the speed of construct vascularization in the early weeks post in vivo implantation.
  • Item
    Thumbnail Image
    Three Dimensional Collagen Scaffold Promotes Intrinsic Vascularisation for Tissue Engineering Applications
    Chan, EC ; Kuo, S-M ; Kong, AM ; Morrison, WA ; Dusting, GJ ; Mitchell, GM ; Lim, SY ; Liu, G-S ; Lai, J-Y (PUBLIC LIBRARY SCIENCE, 2016-02-22)
    Here, we describe a porous 3-dimensional collagen scaffold material that supports capillary formation in vitro, and promotes vascularization when implanted in vivo. Collagen scaffolds were synthesized from type I bovine collagen and have a uniform pore size of 80 μm. In vitro, scaffolds seeded with primary human microvascular endothelial cells suspended in human fibrin gel formed CD31 positive capillary-like structures with clear lumens. In vivo, after subcutaneous implantation in mice, cell-free collagen scaffolds were vascularized by host neovessels, whilst a gradual degradation of the scaffold material occurred over 8 weeks. Collagen scaffolds, impregnated with human fibrinogen gel, were implanted subcutaneously inside a chamber enclosing the femoral vessels in rats. Angiogenic sprouts from the femoral vessels invaded throughout the scaffolds and these degraded completely after 4 weeks. Vascular volume of the resulting constructs was greater than the vascular volume of constructs from chambers implanted with fibrinogen gel alone (42.7±5.0 μL in collagen scaffold vs 22.5±2.3 μL in fibrinogen gel alone; p<0.05, n = 7). In the same model, collagen scaffolds seeded with human adipose-derived stem cells (ASCs) produced greater increases in vascular volume than did cell-free collagen scaffolds (42.9±4.0 μL in collagen scaffold with human ASCs vs 25.7±1.9 μL in collagen scaffold alone; p<0.05, n = 4). In summary, these collagen scaffolds are biocompatible and could be used to grow more robust vascularized tissue engineering grafts with improved the survival of implanted cells. Such scaffolds could also be used as an assay model for studies on angiogenesis, 3-dimensional cell culture, and delivery of growth factors and cells in vivo.
  • Item
    No Preview Available
    Enhanced liver progenitor cell survival and differentiation in vivo by spheroid implantation in a vascularized tissue engineering chamber
    Yap, KK ; Dingle, AM ; Palmer, JA ; Dhillon, RS ; Lokmic, Z ; Penington, AJ ; Yeoh, GC ; Morrison, WA ; Mitchell, GM ( 2013)
  • Item
    Thumbnail Image
    Enhanced liver progenitor cell survival and differentiation in vivo by spheroid implantation in a vascularized tissue engineering chamber
    Yap, KK ; Dingle, AM ; Palmer, JA ; Dhillon, RS ; Lokmic, Z ; Penington, AJ ; Yeoh, GC ; Morrison, WA ; Mitchell, GM (ELSEVIER SCI LTD, 2013-05)
    Liver tissue engineering is hampered by poor implanted cell survival due to inadequate vascularization and cell-cell/cell-matrix interactions. Here, we use liver progenitor cell (LPC) spheroids to enhance cell-cell/cell-matrix interactions, with implantation into an angiogenic in vivo mouse chamber. Spheroids were generated in vitro in methylcellulose medium. Day 2 spheroids were optimal for implantation (22,407 +/-645 cells/spheroid), demonstrating maximal proliferation (Ki67 immunolabeling) and minimal apoptosis (caspase-3 immunolabelling). In vivo chambers established bilaterally on epigastric vessels of immunodeficient mice were implanted with equivalent numbers of LPCs as a cell suspension (200,000 cells), or spheroids (9 spheroids). At day 14, a trend of increased LPC survival was observed in spheroid-implanted chambers [pan-cytokeratin (panCK+) cells, p = 0.38, 2.4 fold increase)], with significantly increased differentiation [cytokeratin 18 (CK18+) cells, p < 0.002, 5.1 fold increase)] compared to cell suspension-implanted chambers. At day 45, both measures were significantly increased in spheroid-implanted chambers (panCK, p < 0.006, 16 fold increase) (CK18, p < 0.019, 6 fold increase). Hepatic acini/plates of CK18 + cells expressed hepatocyte nuclear factor 4-α and β-catenin, indicating ongoing hepatic differentiation. Spheroid cell-delivery significantly increased LPC survival and differentiation compared to conventional cell suspensions. This LPC spheroid/vascularized chamber model has clinical potential to generate three-dimensional vascularized liver tissue for liver replacement.