Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 2 of 2
  • Item
    Thumbnail Image
    A clinical report on speech production of cochlear implant users
    Dawson, P. W. ; Blamey, P. J. ; Dettman, S. J. ; Rowland, L. C. ; Barker, E. J. ; Tobey, E. A. ; Busby, P. A. ; Cowan, R. C. ( 1995)
    Objective: The aim was to assess articulation and speech intelligibility over time in a group of cochlear implant users implanted at 8 yr or over. The hypothesis was that the postoperative speech production performance would be greater than the preoperative performance. Design: A test of intelligibility using sentences and an articulation test measuring non-imitative elicited speech were administered to 11 and 10 subjects, respectively, who were implanted with the 22-electrode cochlear implant. Nine subjects received both tests. Age at implantation ranged from 8 yr to 20 yr and implant use ranged from 1 yr to 4 yr 5 mo. Results: For both the intelligibility and articulation tests roughly half of the subjects showed significant improvements over time and group mean postoperative performance significantly exceeded preoperative performance. Improvements occurred for front, middle, and back consonants; for stops, fricatives, and glides and for voiceless and voiced consonants. Conclusions: Despite being deprived of acoustic speech information for many childhood years, roughly half of the patients assessed showed significant gains in speech intelligibility and articulation postimplantation. The lack of a control group of non-implanted patients means that we cannot separate out the influence of the implant on speech production from other influences such as training and tactile-kinaesthetic feedback.
  • Item
    Thumbnail Image
    The effects of auditory feedback from the nucleus cochlear implant on the vowel formant frequencies produced by children and adults
    Richardson, Louise M. ; Busby, Peter A. ; Blamey, Peter J. ; Dowell, Richard C. ; Clark, Graeme M. ( 1993)
    Cochlear implants provide an auditory signal with which profoundly deaf users may monitor their own speech production. The vowel production of two adults and three children who used the Nucleus multiple-electrode cochlear implant was examined to assess the effect of altered auditory feedback. Productions of words were recorded under conditions where the talkers received auditory feedback (speech processor turned on) and where no auditory feedback was provided (speech processor turned off). Data were collected over 3 days at weekly intervals. First and second formant frequencies were measured and the data were analysed to assess significant differences between auditory feedback conditions, vowel context, and data collection points. Overall, the results varied across talkers, across the data collection days, and depended on the consonant environment of the vowel. However, two effects of auditory feedback were noted. First, there was a generalized shift in first formant frequencies between the processor on and processor off conditions across three of the five subjects, but the shift differed in direction for each subject. Second, for three of the five talkers, the two front vowels /ε/ and /I/ were more neutralised in the absence of auditory feedback. However, this effect was less pronounced than that noted by previous studies.