Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 4 of 4
  • Item
    Thumbnail Image
    A clinical report on speech production of cochlear implant users
    Dawson, P. W. ; Blamey, P. J. ; Dettman, S. J. ; Rowland, L. C. ; Barker, E. J. ; Tobey, E. A. ; Busby, P. A. ; Cowan, R. C. ( 1995)
    Objective: The aim was to assess articulation and speech intelligibility over time in a group of cochlear implant users implanted at 8 yr or over. The hypothesis was that the postoperative speech production performance would be greater than the preoperative performance. Design: A test of intelligibility using sentences and an articulation test measuring non-imitative elicited speech were administered to 11 and 10 subjects, respectively, who were implanted with the 22-electrode cochlear implant. Nine subjects received both tests. Age at implantation ranged from 8 yr to 20 yr and implant use ranged from 1 yr to 4 yr 5 mo. Results: For both the intelligibility and articulation tests roughly half of the subjects showed significant improvements over time and group mean postoperative performance significantly exceeded preoperative performance. Improvements occurred for front, middle, and back consonants; for stops, fricatives, and glides and for voiceless and voiced consonants. Conclusions: Despite being deprived of acoustic speech information for many childhood years, roughly half of the patients assessed showed significant gains in speech intelligibility and articulation postimplantation. The lack of a control group of non-implanted patients means that we cannot separate out the influence of the implant on speech production from other influences such as training and tactile-kinaesthetic feedback.
  • Item
    Thumbnail Image
    Habilitation issues in the management of children using the cochlear multiple-channel cochlear prosthesis
    Cowan, Robert S. C. ; Barker, Elizabeth J. ; Dettman, Shani J. ; Blamey, Peter J. ; RANCE, GARY ; Sarant, Julia Z. ; Galvin, Karyn L. ; Dawson, Pam W. ; Hollow, Rod ; Dowell, Richard C. ; PYMAN, BRIAN ; Clark, Graeme M. (Wien, 1994)
    Since 1985, a significant proportion of patients seen in the Melbourne cochlear implant clinic have been children. The children represent a diverse population, with both congenital and acquired hearing-impairments, a wide-range of hearing levels pre-implant, and an age range from 2 years to 18 years. The habilitation programme developed for the overall group must be flexible enough to be tailored to the individual needs of each child, and to adapt to the changing needs of children as they progress. Long-term data shows that children are continuing to show improvements after 5-7 years of device use, particularly in their perception of open-set words and sentences. Habilitation programs must therefore be geared to the long-term needs of children and their families. Both speech perception and speech production need to be addressed in the specific content of the habilitation program for any individual child. In addition, for young children, the benefits of improved speech perception should have an impact on development of speech and language, and the focus of the programme for this age child will reflect this difference in emphasis. Specific materials and approaches will vary for very young children, school-age and teenage children. In addition, educational setting will have a bearing on the integration of listening and device use into the classroom environment.
  • Item
    Thumbnail Image
    Factors in the development of a training program for use with tactile devices
    Galvin, Karyn L. ; Cowan, Robert S.C. ; Sarant, Julia Z. ; Blamey, Peter J. ; Clark, Graeme M. ( 1993)
    A review of the literature suggests that, in order to maximize the benefits available through a tactile device, it must be accompanied by an effective and adaptive training program. There are a number of factors to consider in the design of such a training program, including the type of tasks and response formats to include, the amount of training, subject motivation and device use, the characteristics of the potential user population, the specific device to be used and the type of information it provides, and the evaluation procedures to be followed. The type and saliency of the information provided by a particular tactile device are highlighted as the most important yet neglected consideration in designing a training program. The training program used with the University of Melbourne’s multiple-channel electrotactile device is presented to show how these important factors may be addressed, to indicate the flexibility required in a training program, and to provide a general framework on which researchers may base the development of programs for other tactile devices.
  • Item
    Thumbnail Image
    The effect of language knowledge on speech perception: what are we really assessing? [Abstract]
    Sarant, J. Z. ; Blamey, P. J. ; Cowan, R. S. C. ; Clark, Graeme M. ( 1996)
    It is a common finding that many hearing-impaired children have poorer language skills than their normally-hearing peers of the same age. It is also logical to assume that the measurement of open-set speech perception in children with cochlear implants could be affected by limited receptive vocabulary and syntactic knowledge. Therefore, we may be significantly underestimating the speech perception abilities of some hearing-impaired children.