Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 4 of 4
  • Item
    Thumbnail Image
    Use of a multichannel electrotactile speech processor by profoundly hearing-impaired children in a total communication environment
    Galvin, Karyn L. ; Cowan, Robert S. C. ; Sarant, Julia Z. ; Alcantara, Joseph I. ; Blamey, Peter J. ; Clark, Graeme M. ( 1991)
    As part of a larger subject group, four profoundly hearing-impaired children enrolled in a total communication educational program were fitted with the University of Melbourne's multichannel electrotactile speech processor (Tickle Talker). Sound detection thresholds for pure tones were at lower levels with the tactile device than with hearing aids, especially for high frequency sounds above 2 kHz. Two of the children also detected all speech sounds of the Ling five-sound test at normal conversational levels using only the Tickle Talker. The children were able to use tactile input to achieve higher scores on three speech feature subtests of the PLOTT test when using the Tickle Talker plus hearing aids as compared to hearing aids alone. Mean improvements were 22.4 percent on vowel length, 28 percent on vowel identification, and 35 percent on consonant manner. Improvements were also shown by individual children on the closed-set WIPI and open-set PBK word tests, and on the open-set BKB sentence test, when the Tickle Talker was combined with hearing aids, and with hearing aids and lipreading. Comparisons of these results with those of children using the Tickle Talker in other educational settings show that children in a total communication environment can potentially benefit to a similar degree from use of tactual input. Anecdotal reports from the children and school staff members indicated that daily use of the Tickle Talker did not interfere with the signing aspects of total communication.
  • Item
    Thumbnail Image
    Perception of multiple electrode stimulus patterns: implications for design of an electrotactile speech processor
    Cowan, Robert S. C. ; Blamey, Peter J. ; Sarant, Julia Z. ; Galvin, Karyn L. ; Clark, Graeme M. ( 1991)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Preliminary evaluation of a wearable multichannel electrotactile speech processor [Abstract]
    Cowan, R. S. C. ; Blamey, P. J. ; Alcantara, J. I. ; Whitford, L. W. ; Clark, Graeme M. ( 1988)
    Speech discrimination testing, using both open-and closed-set materials was carried out with four severely-to-profoundly hearing impaired adults. and seven normally hearing subjects, to assess performance of a wearable eight-channel electrotactile aid (Tickle Talker). The device consisted of a handset composed of nine electrodes, a stimulator-unit, and a speech processor and input microphone. Eight small electrodes were located over the digital nerve bundles on each side of the four fingers of one hand, and a larger common electrode was placed on the wrist. Subjects perceived eight separate channels of information, each corresponding to a stimulus on one side of one finger. The speech processor provided estimates of second formant frequency, fundamental frequency and amplitude of the speech waveform. These features were coded as electrode position, pulse rate and pulse width respectively. This processing strategy (FOF2AO) is similar to that used in an earlier model of the Cochlear Pty. Ltd. cochlear implant.
  • Item
    Thumbnail Image
    Preliminary evaluation of a multichannel electrotactile speech processor
    Cowan, R. S. C. ; Alcantara, J. I. ; Blamey, P. J. ; Clark, Graeme M. ( 1988)
    Abstract not available due to copyright.