Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 6 of 6
  • Item
    Thumbnail Image
    A comparison of Tactaid II+ and Tactaid 7 use by adults with a profound hearing impairment
    Galvin, Karyn L. ; Mavrias, Gina ; Moore, Alessandra ; Cowan, Robert S. C. ; Blamery, Peter J. ; Clark, Graeme M. ( 1999)
    Objective: To evaluate and compare use of the Tactaid II+ and the Tactaid 7, in terms of speech perception, by adults with a hearing impairment. Design: Eight adults used one device daily for approximately 10 wk and attended seven training sessions. Performance was measured with tests of phonetic contrast perception, closed-set vowel and consonant identification, word and phoneme recognition in monosyllabic word lists, word recognition in sentences and speechtracking rate. A questionnaire was also administered. The protocol was repeated with the alternative device. Results: With each device, the group discriminated most phonetic contrasts at better-than-chance levels and demonstrated somewhat enhanced visual or auditory-visual perception when measured in terms of vowel identification, monosyllabic word recognition and speechtracking rate. An increase in speechtracking rate was also demonstrated for some individuals. Subjects generally reported little subjective improvement in speech perception and production, but were satisfied with the physical attributes of each device. Five of six subjects preferred the Tactaid 7. Conclusions: The Tactaid II+ and the Tactaid 7 provided suprasegmental and segmental information, enabling the group to discriminate phonetic contrasts and improve their perception of some speech materials. No consistent advantage was found for either device, thought most subjects preferred the Tactaid 7. Alternatives likely to provide a greater benefit to communication should be considered before Tactaid fitting.
  • Item
    Thumbnail Image
    Studies in tactile speech perception using the University of Melbourne Tickle Talker [Abstract]
    Galvin, K. L. ; Cowan, R. S. C. ; Blamey, P. J. ; Oerlemans, M. ; Ginis, J. ; Mavrias, G. ; Moore, A. ; Lu, A. ; Millard, R. ; Clark, Graeme M. ( 1998)
    During the past four years, a series of studies have been undertaken investigating the perception of speech presented through the tactile modality. These studies formed part of a project to develop an effective and safe electro tactile speech perception device for those children and adults requiring additional communication assistance to that provided by hearing aids, but unable to benefit from cochlear implants.
  • Item
    Thumbnail Image
    Speech perception and spoken language in children with impaired hearing
    Clark, Graeme M. ; Wright, M. ; Tooher, T. ; Psarron, C. ; Godwin, G. ; Rennie, M. ; Meskin, T. ; Blamey, P. ; Sarant, J. ; Serry, T. ; Wales, R. ; James, C. ; Barry, J. ( 1998)
    Fifty seven children with impaired hearing aged 4-12 years were evaluated with speech perception and language measures as the first stage of a longitudinal study. The Clinical Evaluation of Language Fundamentals (CELF) and Peabody Picture Vocabulary Test (PPVT) were used to evaluate the children's spoken language. Regression analyses indicated that scores on both tests were significantly correlated with chronological age, but delayed relative to children with normal hearing. Performance increased at 45% of the rate expected for children with normal hearing for the CELF, and 62% for the PPVT. Perception scores were not significantly correlated with chronological age, but were highly correlated with results on the PPVT and CELF. The data suggest a complex relationship whereby hearing impairment reduces speech perception, which slows language development, which has a further adverse effect on speech perception.
  • Item
    Thumbnail Image
    Rehabilitation strategies for adult cochlear implant users
    Dowell, R. C. ; Blamey, P. J. ; Clark, Graeme M. (Monduzzi Editore, 1997)
    This paper summarizes open-set speech perception results using audition alone for a large group of adult Nucleus cochlear implant users in Melbourne. The results show wide variation in performance but significant improvement over the years from 1982 to 1995. Analysis of these results shows that speech processor developments have made the major contribution to this improvement over this time. Recent results for patients using the SPECTRA-SPEAK processor show !hat most subjects obtain good speech perception within six months of implantation and the need for intensive auditory training is minimal for many of these patients. Postoperative care should encourage consistent device use by providing opportunities for success and providing long term technical support for implant users. In some cases, including elderly patients, those with long term profound deafness, and those with special needs, there will still be a need for additional rehabilitation and auditory training support.
  • Item
    Thumbnail Image
    Factors affecting outcomes in children with cochlear implants
    Dowell, R. C. ; Blamey, P. J. ; Clark, Graeme M. (Monduzzi Editore, 1997)
    Open-set speech perception tests were completed for a group of 52 children and adolescents who were long-term users of the Nucleus multiple channel cochlear prosthesis. Results showed mean scores for the group of 32.4% for open-set BKE sentences and 48.1% for phonemes in open-set monosyllabic words. Over 80% of the group performed significantly on these tas1cs. Age at implantation was identified as a significant factor affecting speech perception performance with improved scores for children implanted early. This factor was evident in the results at least down to the age of three years. Duration.. of profound hearing loss, progressive hearing loss, educational program and preoperative residual hearing were also identified as significant factors that may affect speech perception performance.
  • Item
    Thumbnail Image
    Pre- & post-operative factors affecting speech perception in adult cochlear implant users
    Blamey, Peter J. ; Clark, Graeme M. ; Dowell, Richard C. ( 1997)
    A common feature of published studies of cochlear implantation is a very wide range of performance levels within a group of patients. It is well-established that preoperative factors including duration of deafness, age at implantation, duration of implant use and etiology can have statistically significant effects on speech perception with a cochlear implant, but they do not account for a very high proportion of the variance within groups of implant users. The biological basis for these effects is not well established. For example, it is unclear whether the effect of duration of deafness is due to a decrease in the number of surviving ganglion cells in the cochlea, to the detailed distribution of functional neurons within the cochlea, to degeneration of nerve function at higher auditory centers, to plastic neural effects during deafness, or to a combination of all of these mechanisms. Data for other factors may cast some light on these possibilities.