    A clinical report on speech production of cochlear implant users
    Dawson, P. W. ; Blamey, P. J. ; Dettman, S. J. ; Rowland, L. C. ; Barker, E. J. ; Tobey, E. A. ; Busby, P. A. ; Cowan, R. C. ( 1995)
    Objective: The aim was to assess articulation and speech intelligibility over time in a group of cochlear implant users implanted at 8 yr or over. The hypothesis was that the postoperative speech production performance would be greater than the preoperative performance. Design: A test of intelligibility using sentences and an articulation test measuring non-imitative elicited speech were administered to 11 and 10 subjects, respectively, who were implanted with the 22-electrode cochlear implant. Nine subjects received both tests. Age at implantation ranged from 8 yr to 20 yr and implant use ranged from 1 yr to 4 yr 5 mo. Results: For both the intelligibility and articulation tests roughly half of the subjects showed significant improvements over time and group mean postoperative performance significantly exceeded preoperative performance. Improvements occurred for front, middle, and back consonants; for stops, fricatives, and glides and for voiceless and voiced consonants. Conclusions: Despite being deprived of acoustic speech information for many childhood years, roughly half of the patients assessed showed significant gains in speech intelligibility and articulation postimplantation. The lack of a control group of non-implanted patients means that we cannot separate out the influence of the implant on speech production from other influences such as training and tactile-kinaesthetic feedback.
  • Item
    Thumbnail Image
    Role of a multichannel electrotactile speech processor in a cochlear implant program for profoundly hearing-impaired adults
    Cowan, Robert S. C. ; Blamey, Peter J. ; Sarant, Julia Z. ; Galvin, Karyn L. ; Alcantara, Joseph I. ; Whitford, Lesley A. ; Clark, Graeme M. ( 1991)
    Four profoundly hearing-impaired adults who did not meet current selection criteria for implantation at the University of Melbourne were each fitted with a wearable multichannel electrotactile speech processor (Tickle Talker). The subjects were evaluated with a test battery of speech discrimination tests subsequent to training in use of the device. Thresholds for detection of pure tones were lower for the Tickle Talker than for hearing aids across the frequency range 250 to 4000 Hz. Mean speech detection thresholds for the Ling 5-sound test showed that all sounds were detected by users of the electrotactile device at normal conversational speech intensity levels. Mean speech discrimination scores were significantly higher (p < 0.05) in the tactually aided condition as compared with the tactually unaided for identification of vowels and consonants, on open-set words, open-set sentences, and on connected discourse tracking. Mean scores increased by 20% for vowels, 19% for consonants, 30% for openset words, and 25% for open-set sentences when the Tickle Talker was used in a multimodal combination with lipreading or lipreading and hearing aids. Speechtracking rates for three subjects showed increases of from 18 to 28 wpm when the tactile device was used. Comparison of tactually aided versus unaided tracking rates for two subjects with long-term experience shows continuing improvement with additional experience with the device. These results demonstrate that hearing impaired adults not meeting selection criteria for cochlear implantation may benefit from use of an electrotactile speech processor, and highlight the potential benefits from integration of such devices into cochlear implant programs for profoundly hearing-impaired patients.