Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 6 of 6
  • Item
    Thumbnail Image
    A comparison of a new prototype Tickle Talker with a Tactaid 7
    Galvin, Karyn L. ; Ginis, Jan ; Cowan, Robert S. C. ; Blamey, Peter J. ; Clark, Graeme M. ( 2001)
    This study compared the speech perception enhancement provided by two multichannel tactile aids: a new version of the Tickle TalkerT™ and the Tactaid 7. The subjects' impression of benefit was also examined. In an AB pattern, six adults with hearing impairment used each device daily for approximately 18 weeks and attended 12 training sessions. When tactile information was provided, the group demonstrated a significant enhancement for the perception of words (mean 17.2%) and phonemes (mean 12.9%) in monosyllabic word lists, words in sentences (mean 14.2%) and speech tracking (mean 7.7 wpm). The Tactaid 7 provided a significantly greater enhancement for the perception of words (21 % versus 13.4%), phonemes (16.7% versus 9.1%) and some speech features in monosyllabic word lists. Subjective ratings were slightly higher for the Tactaid 7, and four subjects preferred this device. Either device may be suitable for those not able or willing to have a cochlear implant.
  • Item
    Thumbnail Image
    Generalisation of tactile perceptual skills to new context following tactile-alone word recognition training with the Tickle Talker
    Galvin, Karyn L. ; Blamey, Peter J. ; Cowan, Robert S. C. ; Oerlemans, Michael ; Clark, Graeme M. ( 2000)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Design fundamentals for electrotactile devices: the Tickle Talker case study
    Cowan, Robert S. C. ; Galvin, Karyn L. ; Blamey, Peter J. ; Sarant, Julia Z. (Whurr, 1995)
    Since the work of Gault in the 1920s, the literature has chronicled the development of numerous tactile devices for use by the hearing impaired in improving communication. Devices have been developed to target improvements in both speech perception and speech production. In each development, the inventors have attempted to encode speech information through stimulation of the intact kinaesthetic system of the individual, as a supplement or replacement for speech input available from the damaged auditory pathway.
  • Item
    Thumbnail Image
    Improved electrotactile speech processor: Tickle Talker
    Cowan, R. S. C. ; Galvin, K. L. ; Sarant, J. Z. ; Millard, R. ; Blamey, P. J. ; Clark, Graeme M. ( 1995)
    The Tickle Talker, an eight-channel electrotactile speech processor, has been developed from continuing research at the University of Melbourne. 'The development of the device has focused on production of reliable speech-processing hardware, design of cosmetically and ergonometrically acceptable electrode transducers, implementation of acute and chronic biomedical studies demonstrating device safety, design and testing of alternative speech-encoding strategies to provide benefit to speech perception and production, and design and testing of appropriate training methods for optimizing benefits. The Tickle Talker has been shown to provide benefits in supplementing lipreading or aided residual hearing for hearing-impaired adults and children. Improvements in speech processing have resulted in an increase in benefits to speech perception, and open the way for more flexible approaches to encoding speech input. Continuing development of the electrode circuitry has now produced a device that is robust and has an extended battery life. Safety studies have clearly demonstrated that there are no long-term contraindications to device use. The results suggest that the device has a role to play in rehabilitation programs for severely and profoundly hearing-impaired adults and children.
  • Item
    Thumbnail Image
    The Tickle Talker: a speech perception aid for profoundly hearing impaired children [Abstract]
    Cowan, Robert S. C. ; Sarant, Julia Z. ; Galvin, Karyn L. ; Alcantara, Joseph I. ; Blamey, Peter J. ; Clark, Graeme M. ( 1990)
    Fifteen prelingually profoundly hearing-impaired children participated in speech perception training and evaluation, to assess potential benefits from use of the Tickle Talker. This device, a multichannel electrotactile speech processor, developed by Cochlear Pty. Ltd. and the University of Melbourne, presents speech as a pattern of electrical sensations felt on the fingers. The eight small electrodes are located over the digital nerve bundles, on both sides of the four fingers of the non-dominant hand. Speech processing hardware is similar to that used in the 22-channel cochlear implant. In the encoding strategy, second formant frequency (F2) is presented as electrode position, speech waveform amplitude as stimulus strength, and fundamental frequency (FO) as rate of stimulation. Each child participated in an ongoing training program involving clinicians, teachers and parents. The evaluation program included measures of sound and speech detection thresholds, and discrimination of speech features, words and open-set sentences. Both individual and mean scores for all the children demonstrate significant improvements in speech perception scores when input from the Tickle Talker is combined with either aided-residual hearing, or aided residual hearing and lipreading. These results are consistent with those previously reported for profoundly hearing-impaired adults using the Tickle Talker, and indicate that children are able to integrate speech information provided through the tactual modality with information from vision or residual hearing.
  • Item
    Thumbnail Image
    Development of an advanced electrotactile speech processor [Abstract]
    Cowan, Robert S. C. ; Blamey, Peter J. ; Glavin, K. L. ; Sarant, J. Z. ; Millard, R. ; Clark, Graeme M. ( 1992)
    Initial studies with a multiple channel electrotactile speech processor ('Tickle Talker') showed that profoundly hearing-impaired adults and children could achieve significant improvements on speech perception tests through use of tactual-encoded estimates of fundamental frequency, second formant frequency and amplitude envelope. Results showed that the device provided tactual cues which could be used to discriminate speech features such as vowel length and place, and consonant manner and voicing. However, discrimination of initial consonant voicing was not as consistent as for other features. Accurate discrimination of consonant voicing and manner (particularly high frequency information) is critical, since this Information is generally inaudible through hearing aids, and difficult to lipread.