  • Item
    Thumbnail Image
    Pitch perception for different modes of stimulation using the Cochlear multiple-electrode prosthesis
    Busby, P. A. ; Whitford, L. A. ; Blamey, P. J. ; Richardson, L. M. ; Clark, Graeme M. ( 1994)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    A review of the biological, psychophysical, and speech processing principles used to design the tickle talker
    Blamey, P. J. ; Cowan, R. S. C. ; Alcantara, J. I. ; Whitford, L. A. ; Galvin, K. L. ; Sarant, J. Z. ; Clark, Graeme M. ( 1992)
    The Tickle Talker is a wearable electrotactile speech processor, designed to be used by profoundly hearing-impaired children and adults in conjunction with lipreading and residual hearing. The effectiveness of such a device is affected by an interaction between biological, human engineering, psychophysical, and speech processing considerations. The requirements, the design principles, and the performance of the Tickle Talker in each of these areas will be discussed. Electrical stimulation of the nerve bundles lying along the sides of the fingers was chosen to provide safe, comfortable, energy-efficient stimulation of a well-organised and sensitive part of the tactile sensory system. This is achieved at a small cost to the appearance and mobility of one hand when using the Tickle Talker. The biphasic pulse waveform used to stimulate the nerve bundles has been chosen to ensure a biologically safe stimulus. The electrical parameters (pulse duration, pulse rate, and electrode position) that are used to encode speech information are varied within ranges that are matched to the characteristics of the tactile sense. The usable ranges and information-carrying potential of each of these parameters have been assessed in psychophysical experiments. A comparison of these results with similar experimental data for cochlear implant and hearing aid users is instructive in assessing the possible limitations of tactile and auditory speech processors. The results discussed will include the discrimination and identification of stimuli differing in intensity, duration and pulse rate; the identification of different spatial patterns of stimulation, and the detection of gaps in stimuli. In most respects, the tactile results are similar to the corresponding auditory measures. The resolution of temporal differences such as pulse rate discrimination or gap detection are generally not as good as in the auditory case, but may be as good or better than the corresponding results for some profoundly hearing-impaired individuals. The speech processor used in the Tickle Talker is a "feature extraction" device that explicitly estimates the second formant frequency, amplitude envelope, and fundamental frequency of the voice and encodes them in terms of electrode position, pulse width and pulse rate of the electrical stimulation pattern. Consideration of the psychophysical results and the speech information available from these parameters allows optimization of the Tickle Talker's operation and a broad estimation of its potential performance in speech discrimination. The perception of duration and place of articulation (front/back) of vowels, and the manner and voicing of consonants are expected to be improved by the Tickle Talker. Prosodic variations conveyed by pulse rate are expected to be perceived by some users, but not all. High frequency consonants such as: /s/,/z/./?/, and /t?/ are encoded in a particularly salient manner by the Tickle Talker.
  • Item
    Thumbnail Image
    Clinical experience with the University of Melbourne multichannel electrotactile speech processor (Tickle Talker)
    Cowan, Robert S. C. ; Blamey, Peter J. ; Sarant, J. Z. ; Galvin, K. L. ; Alcantara, J. I. ; Whitford, Lesley A. ; Clark, Graeme M. ( 1992)
    The Tickle Talker is a multiple channel electrotactile speech processor, developed for use by profoundly hearing-impaired adults and children. The device is intended to be used in combination with lipreading and aided residual hearing, to assist the greatest potential range of users. Sound detection and speech reception threshold levels for a group of 14 congenitally hearing-impaired children were shown to be lower when using the Tickle Talker than for hearing aids across the speech frequency range. Tactile-alone feature contrast testing with adults demonstrated that both segmental and suprasegmental speech feature information was available from the tactual display presented by the Tickle Talker. Clinical results from an ongoing program involving fourteen hearing-impaired children demonstrate benefits in speech perception achieved through use of the Tickle Talker. The children have a range of degree of hearing impairment and educational setting. Results show improvements in discrimination scores for vowel and consonant speech features, and increased scores for recognition of closed-set words and for open-set words and sentences. In addition, anecdotal evidence indicates changes in speech production which may be attributed to perceptual input from the device (both from perception of other speakers, and from voice self-monitoring). Results from a group of 4 adult patients show that tactile input may be effectively combined with either aided residual hearing, or aided residual hearing and lipreading to improve speech discrimination across a similar range of closed and open-set word and sentence tests and on speech tracking. The results indicate that some specific tailoring of the speech information provided through the device for the needs of users with differing degrees of hearing-impairment may be required to optimize potential benefits to speech discrimination.
  • Item
    Thumbnail Image
    Speech perception, production and language results in a group of children using the 22-electrode cochlear implant
    Blamey, P. J. ; Dawson, P. W. ; Dettman, S. J. ; Rowland, L. C. ; Brown, A. M. ; Busby, P. A. ; Dowell, R. C. ; Rickards, F. W. ; Clark, Graeme M. ( 1992)
    Five children out of a group of nine (aged 5.5 to 19.9 years) implanted with the 22-electrode cochlear implant (Cochlear Ply. Ltd.) have achieved substantial scores on open-set speech tests using hearing without lipreading. Phoneme scores for monosyllabic words ranged from 40% to 72%. Word scores in sentences ranged from 26% to 74%. Four of these five children were implanted during preadolescence. The fifth child, who had a progressive loss and was implanted during adolescence after a short period of very profound deafness, scored highest on all speech perception tests. The remaining four children who did not demonstrate open-set recognition were implanted during adolescence after a long duration of profound deafness. Post-operative performance on closed-set speech perception tests was better than pre-operative performance for all children. Improvements in speech and language assessments were also noted. These improvements tended to be greater for the younger children. The results are discussed with reference to variables which may contribute to successful implant use: such as age at onset, duration of profound hearing loss, age at implantation, aetiology, educational program, and the type of training provided.
  • Item
    Thumbnail Image
    The effects of auditory feedback from the nucleus cochlear implant on the vowel formant frequencies produced by children and adults
    Richardson, Louise M. ; Busby, Peter A. ; Blamey, Peter J. ; Dowell, Richard C. ; Clark, Graeme M. ( 1993)
    Cochlear implants provide an auditory signal with which profoundly deaf users may monitor their own speech production. The vowel production of two adults and three children who used the Nucleus multiple-electrode cochlear implant was examined to assess the effect of altered auditory feedback. Productions of words were recorded under conditions where the talkers received auditory feedback (speech processor turned on) and where no auditory feedback was provided (speech processor turned off). Data were collected over 3 days at weekly intervals. First and second formant frequencies were measured and the data were analysed to assess significant differences between auditory feedback conditions, vowel context, and data collection points. Overall, the results varied across talkers, across the data collection days, and depended on the consonant environment of the vowel. However, two effects of auditory feedback were noted. First, there was a generalized shift in first formant frequencies between the processor on and processor off conditions across three of the five subjects, but the shift differed in direction for each subject. Second, for three of the five talkers, the two front vowels /ε/ and /I/ were more neutralised in the absence of auditory feedback. However, this effect was less pronounced than that noted by previous studies.
  • Item
    Thumbnail Image
    Factors in the development of a training program for use with tactile devices
    Galvin, Karyn L. ; Cowan, Robert S.C. ; Sarant, Julia Z. ; Blamey, Peter J. ; Clark, Graeme M. ( 1993)
    A review of the literature suggests that, in order to maximize the benefits available through a tactile device, it must be accompanied by an effective and adaptive training program. There are a number of factors to consider in the design of such a training program, including the type of tasks and response formats to include, the amount of training, subject motivation and device use, the characteristics of the potential user population, the specific device to be used and the type of information it provides, and the evaluation procedures to be followed. The type and saliency of the information provided by a particular tactile device are highlighted as the most important yet neglected consideration in designing a training program. The training program used with the University of Melbourne’s multiple-channel electrotactile device is presented to show how these important factors may be addressed, to indicate the flexibility required in a training program, and to provide a general framework on which researchers may base the development of programs for other tactile devices.
  • Item
    Thumbnail Image
    Combined electrical and acoustical stimulation using a bimodal prosthesis
    Dooley, Gary J. ; Blamey, Peter J. ; Seligman, Peter M. ; Alcantara, Joseph I. ; Clark, Graeme M. ; Shallop, Jon K. ; Arndt, Patti ; Heller, James W. ; Menapace, Christine M. ( 1993)
    A new device incorporating a cochlear implant speech processor and a speech-processing hearing aid for the un-implanted ear has been designed and tested with four severely hearing-impaired patients. The aim of the device is to provide a more acceptable and effective combination of electrical and acoustic signals to the two ears. When used monaurally, and binaurally in conjunction with the cochlear implant, the speech-processing hearing aid mean scores for open-set sentences, words, and consonants were as good as or better than the mean scores for the patients' own conventional hearing aids. Some patients improved much more than did others. Although not conclusive, these results are encouraging, especially as they were achieved with a laboratory prototype that did not allow the patients to become accustomed to the processor in everyday situations.
  • Item
    Thumbnail Image
    Cochlear implants in children, adolescents, and prelinguistically deafened adults: speech perception
    Dawson, Pam W. ; Blamey, Peter J. ; Rowland, Louise C. ; Dettman, Shani J. ; Clark, Graeme M. ; Busby, Peter A. ; Brown, Alison M. ; Dowell, Richard C. ; Rickards, Field W. ( 1992)
    A group of 10 children, adolescents, and prelinguistically deafened adults were implanted with the 22-electrode cochlear implant (Cochlear Ply Ltd) at the University of Melbourne Cochlear Implant Clinic and have used the prosthesis for periods from 12 to 65 months. Postoperative performance on the majority of closed-set speech perception tests was significantly greater than chance, and significantly better than preoperative performance for all of the patients. Five of the children have achieved substantial scores on open-set speech tests using hearing without lipreading. Phoneme scores in monosyllabic words ranged from 30% to 72%; word scores in sentences ranged from 26% to 74%. Four of these 5 children were implanted during preadolescence (aged 5:5 to 10:2 years) and the fifth, who had a progressive loss, was implanted during adolescence (aged 14:8 years). The duration of profound deafness before implantation varied from 2 to 8 years. Improvements were also noted over postoperative data collection times for the younger children. The remaining 5 patients who did not demonstrate open-set recognition were implanted after a longer duration of profound deafness (aged 13:11to 20:1 years). The results are discussed with reference to variables that may affect implant performance, such as age at onset of loss, duration of profound loss, age at implantation, and duration of implantation. They are compared with results for similar groups of children using hearing aids and cochlear implants.
  • Item
    Thumbnail Image
    Use of a multichannel electrotactile speech processor by profoundly hearing-impaired children in a total communication environment
    Galvin, Karyn L. ; Cowan, Robert S. C. ; Sarant, Julia Z. ; Alcantara, Joseph I. ; Blamey, Peter J. ; Clark, Graeme M. ( 1991)
    As part of a larger subject group, four profoundly hearing-impaired children enrolled in a total communication educational program were fitted with the University of Melbourne's multichannel electrotactile speech processor (Tickle Talker). Sound detection thresholds for pure tones were at lower levels with the tactile device than with hearing aids, especially for high frequency sounds above 2 kHz. Two of the children also detected all speech sounds of the Ling five-sound test at normal conversational levels using only the Tickle Talker. The children were able to use tactile input to achieve higher scores on three speech feature subtests of the PLOTT test when using the Tickle Talker plus hearing aids as compared to hearing aids alone. Mean improvements were 22.4 percent on vowel length, 28 percent on vowel identification, and 35 percent on consonant manner. Improvements were also shown by individual children on the closed-set WIPI and open-set PBK word tests, and on the open-set BKB sentence test, when the Tickle Talker was combined with hearing aids, and with hearing aids and lipreading. Comparisons of these results with those of children using the Tickle Talker in other educational settings show that children in a total communication environment can potentially benefit to a similar degree from use of tactual input. Anecdotal reports from the children and school staff members indicated that daily use of the Tickle Talker did not interfere with the signing aspects of total communication.
  • Item
    Thumbnail Image
    Perception of multiple electrode stimulus patterns: implications for design of an electrotactile speech processor
    Cowan, Robert S. C. ; Blamey, Peter J. ; Sarant, Julia Z. ; Galvin, Karyn L. ; Clark, Graeme M. ( 1991)
    Abstract not available due to copyright.