ItemSpeech perception and spoken language in children with impaired hearingClark, Graeme M. ; Wright, M. ; Tooher, T. ; Psarron, C. ; Godwin, G. ; Rennie, M. ; Meskin, T. ; Blamey, P. ; Sarant, J. ; Serry, T. ; Wales, R. ; James, C. ; Barry, J. ( 1998)Fifty seven children with impaired hearing aged 4-12 years were evaluated with speech perception and language measures as the first stage of a longitudinal study. The Clinical Evaluation of Language Fundamentals (CELF) and Peabody Picture Vocabulary Test (PPVT) were used to evaluate the children's spoken language. Regression analyses indicated that scores on both tests were significantly correlated with chronological age, but delayed relative to children with normal hearing. Performance increased at 45% of the rate expected for children with normal hearing for the CELF, and 62% for the PPVT. Perception scores were not significantly correlated with chronological age, but were highly correlated with results on the PPVT and CELF. The data suggest a complex relationship whereby hearing impairment reduces speech perception, which slows language development, which has a further adverse effect on speech perception.
-
ItemRehabilitation strategies for adult cochlear implant usersDowell, R. C. ; Blamey, P. J. ; Clark, Graeme M. (Monduzzi Editore, 1997)This paper summarizes open-set speech perception results using audition alone for a large group of adult Nucleus cochlear implant users in Melbourne. The results show wide variation in performance but significant improvement over the years from 1982 to 1995. Analysis of these results shows that speech processor developments have made the major contribution to this improvement over this time. Recent results for patients using the SPECTRA-SPEAK processor show !hat most subjects obtain good speech perception within six months of implantation and the need for intensive auditory training is minimal for many of these patients. Postoperative care should encourage consistent device use by providing opportunities for success and providing long term technical support for implant users. In some cases, including elderly patients, those with long term profound deafness, and those with special needs, there will still be a need for additional rehabilitation and auditory training support.
-
ItemFactors affecting outcomes in children with cochlear implantsDowell, R. C. ; Blamey, P. J. ; Clark, Graeme M. (Monduzzi Editore, 1997)Open-set speech perception tests were completed for a group of 52 children and adolescents who were long-term users of the Nucleus multiple channel cochlear prosthesis. Results showed mean scores for the group of 32.4% for open-set BKE sentences and 48.1% for phonemes in open-set monosyllabic words. Over 80% of the group performed significantly on these tas1cs. Age at implantation was identified as a significant factor affecting speech perception performance with improved scores for children implanted early. This factor was evident in the results at least down to the age of three years. Duration.. of profound hearing loss, progressive hearing loss, educational program and preoperative residual hearing were also identified as significant factors that may affect speech perception performance.
-
ItemThe effect of language knowledge on speech perception in children with impaired hearingSarant, J. Z. ; Blamey, P. J. ; Clark, Graeme M. ( 1996)Open-set words and sentences were used to assess auditory speech perception of three hearing-impaired children aged 9 to 15 years using the Nucleus 22channel cochlear implant. Vocabulary and syntax used in the tests were assessed following the initial perception tests. Remediation was given in specific vocabulary and syntactic areas, chosen separately for each child, and the children were reassessed. Two children showed a significant post-remediation improvement in their overall scores on the syntactic test and both perception measures. The third child who was older, had the best language knowledge and the lowest auditory speech perception scores, showed no significant change on any of the measures. Language remediation in specific areas of weakness may be the quickest way to enhance speech perception for some children with impaired hearing in this age range.
-
ItemPitch and vowel perception in cochlear implant usersBlamey, Peter J. ; Parisi, Elvira S. ( 1994)Two methods of determining the pitch or timbre of electrical stimuli in comparison with acoustic stimuli are described. In the first experiment, the pitch of pure tones and electrical stimuli were compared directly by implant users who have residual hearing in the non-implanted ear. This resulted in a relationship between frequency in the non-implanted ear and position of the best-matched electrode in the implanted ear. In the second experiment, one- and two-formant synthetic vowels, with formant frequencies covering the range from 200 to 4000 Hz, were presented to the same implant users through their implant or through their hearing aid. The listeners categorised each stimulus according to the closest vowel from a set of eleven possibilities, and a vowel centre was calculated for each response category for each ear. Assuming that stimuli at the vowel centres in each ear sound alike, a second relationship between frequency and electrode position was derived. Both experiments showed that electrically-evoked pitch is much lower than that produced by pure tones at the corresponding cochlear location in normally-hearing listeners. This helps to explain why cochlear implants with electrode arrays that rarely extend beyond the basal turn of the cochlea have achieved high levels of speech recognition in postlinguistically deafened adults without major retraining or adaptation by the users. The techniques described also have potential for optimising speech recognition for individual implant users.
-
ItemMultisensory speech perception: integration of speech informationOerlemans, Michael ; BLAMEY, PETER ( 1994)Speech perception usually occurs in the context of more than one source of sensory information. The effectiveness of speech perception in these multisensory situations depends on how successfully two or more sources of information are combined. An analysis of auditory-visual (AV) speech perception suggests a model of multisensory integration which argues that the extent of integration depends on the physical and cognitive characteristics of the signals which are combined. It is proposed that such a model can explain observed differences between AV, auditory-tactile (AT) and visual-tactile (VT) combination.
-
ItemUsing an automatic word-tagger to analyse the spoken language of children with impaired hearingBlamey, P. J. ; Grogan, M. L. ; Shields, M. B. ( 1994)The grammatical analysis and description of spoken language of children with impaired hearing is time-consuming, but has important implications for their habilitation and educational management. Word-tagging programs have achieved high levels of accuracy with text and adult spoken language. This paper investigates the accuracy of one automatic word tagger (AUTASYS 3.0 developed for the International Corpus of English project, ICE) on a small corpus of spoken language samples from children using a cochlear implant. The accuracy of the tagging and the usefulness of the results in comparison with more conventional analyses are discussed.
-
ItemCombination and comparison of electric stimulation and residual hearingBLAMEY, PETER ; Dooley, Gary ; Parisi, Elvira ( 1994)Speech processing for cochlear implant users has now reached a level where some severely hearing-impaired hearing aid users may be better aided by a cochlear implant, or a hearing aid and implant together. This paper reviews studies comparing the loudness, pitch, and vowel perception in opposite ears of adults using cochlear implants and hearing aids. A study of nine subjects showed narrow dynamic ranges and steep loudness growth in both ears. Mismatches in aided thresholds and dynamic ranges at different frequencies resulted in highly variable loudness differences between the ears for some subjects. A comparison using pure tones showed that the electric pitch depended on both rate and electrode site. Pitch of electrodes was lower than expected from the characteristic frequency distribution in a normal cochlea. Synthetic vowels were used to show that signals presented via the implant and hearing aid may be perceived as different vowels in the two ears.
-
ItemHabilitation issues in the management of children using the cochlear multiple-channel cochlear prosthesisGalvin Karyn L. ; Dawson Pam W. ; Hollow Rod. ; Dowell Richard C. ; Pyman B. ; Clark Graeme, M. ; Cowan, Robert S. C. ; Barker, Elizabeth J. ; Dettman, Shani J. ; Blamey, Peter J. ; RANCE, GARY ; Zarant, Julia Z. ( 1993)Since 1985, a significant proportion of patients seen In the Melbourne cochlear Implant clinic have been children. The children represent a diverse population, with both congenital and acquired hearing-impairment, a wide-range or hearing levels pre-Implant, and an age range from 2 years to 18 years. The habilitation programme developed for the overall group must be flexible enough to be tailored to the Individual needs of each child, and to adapt to the changing needs or children as they progress. Long-term data shows that children are continuing to show Improvements after 5-7 years of device use, particularly In their perception of open-set words and sentences. Habilitation programs must therefore be geared to the long-term needs of children and their families. Both speech perception and speech production need to be addressed In the specific content of the habilitation program for any Individual child. In addition, for young children, the benefits or Improved speech perception should have an Impact on development of speech and language, and the focus of the programme for this age child will reflect this difference In emphasis. Specific materials and approaches will vary for very young children, school-age and teenage children. In addition, educational selling will have a bearing on the Integration of listening and device use Into the classroom environment.
-
ItemFricative perception by cochlear implant usersBlamey, P. J. ; Tartter, V. C. ( 1992)Three implant users were tested with 45 syllables consisting of[v, f, �, ?, z, s, ?, ?, d?, t ?, ?, , d, n, 1] before the vowels [I ,a,u] with three wearable speech processors. The WSP3 processor coded first and second formant frequencies and amplitudes. The MSP1 processor used a similar scheme with improved measurement and coding of the formants. The MSP2 processor added amplitude information from three higher frequency bands. Average scores were 42% for WSP3, 54% for MSP1, and 57% for MSP2. Perception of voicing, manner, and place of articulation of the consonants was significantly greater for the MSP processors than the WSP3 processor. Place perception was slightly higher for MSP2 than MSP1. The listeners used three perceptual dimensions which were highly correlated with the frequencies and amplitudes of peaks in the low frequency region of the frication spectrum, amplitudes of high frequency peaks, and duration of the frication noise.