Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 9 of 9
  • Item
    Thumbnail Image
    A multiple-channel cochlear implant: an evaluation using nonsense syllables
    Clark, Graeme M. ; Tong, Yit Chow ; Martin, Lois F. ; Busby, Peter A. ; Dowell, Richard C. ; Seligman, Peter M. ; Patrick, James F. ( 1981)
    A study using nonsense syllables has shown that a multiple-channel cochlear implant with speech processor is effective in providing information about, voicing and manner and to a lesser extent place distinctions. These distinctions supplement lipreading cues. Furthermore, the average percentage improvements in overall identification scores for multiple-channel electrical stimulation and lipreading compared to lipreading alone were 71% for a laboratory-based speech processor and 122 % for a wearable unit.
  • Item
    Thumbnail Image
    A multiple-channel cochlear implant: an evaluation using an open-set word test
    Clark, Graeme M. ; Tong, Y. C. ; Martin, L. F. ; Busby, P. A. ( 1981)
    Multiple-channel electrical stimulation of the hearing nerve in conjunction with speech reading has helped two post-lingually deaf patients with total hearing losses understand running speech in every day situations. This has been confirmed using open-set phonetically balanced word tests, where the patients achieved 60% and 40% scores with isolated-words and 80% and 73% for phonemes-in-isolated words. The tests also showed that the cochlear implant improved word recognition by a factor of four in one patient and two in another compared with speechreading alone. The speech processor used extracted the voicing frequency and energy and the frequency and energy of the dominant spectral peak in the mid-frequency range. The parameters for voicing determined the rate of stimulation for all electrodes, and the parameters for the dominant spectral peak in the midfrequency range determined the site of electrode stimulation and current level.
  • Item
    Thumbnail Image
    Psychophysical and speech perception studies on two multiple-channel cochlear implant patients
    Tong, Y. C. ; Millar, J. B. ; Clark, Graeme M. ; Martin, L. F. ; Busby, P. A. ; Patrick, J. F. (Cambridge University Press, 1980)
    Preliminary studies on our first patient with a multiple channel cochlear implant (Tong et al., 1979) showed that he was able to associate the hearing sensations produced by electrical stimulation of residual auditory nerve fibres with different vowel (spectral) colours. The frequencies characterizing the vowel colours produced by stimulation at single scala tympani electrodes were, in general, closely related to the tonotopical organization of the� cochlea. Furthermore, results from these studies indicated that the pitch produced by single-electrode stimulation increased with pulse rate, and that the loudness increased with current level.
  • Item
    Thumbnail Image
    Educational assessment and management of children with multichannel cochlear implants
    Nienhuys, T. G. ; Musgrave, G. N. ; Busby, P. A. ; Blamey, P. J. ; Nott, P. ; Tong, Y. C. ; Dowell, R. C. ; Brown, L. F. ; Clark, Graeme M. ( 1987)
    This paper describes the assessment and training program to evaluate speech, language, and communication skills of profoundly deaf children during and after training. Two sensory aids/prostheses are used: hearing aids and the Nucleus multichannel cochlear implant. Using a single-subject time-series experimental design, children's speech, language, and communication skills are assessed. For speech skills, assessment includes formal tests of articulation and intelligibility, syllable stress and process analyses, analyses of suprasegmental features, and voice quality. For general communication abilities, conversational skills with different speakers, story production skills, comprehension and expression of procedural information, discourse skills, and a measure of conversational interaction skills (pragmatics) are analyzed at regular intervals. Regular observations also sample the subjects' mode and frequency of interactions with individuals and groups in the school and home setting. Normative tests and formal analyses of language samples are also used to assess the overall language age of the child, vocabulary size, and kinds of expressive and receptive, syntactic, and semantic ability.
  • Item
    Thumbnail Image
    Preliminary results for the Cochlear Corporation multielectrode intracochlear implant in six prelingually deaf patients
    Clark, Graeme M. ; Busby, Peter A. ; Roberts, Susan A. ; Dowell, Richard C. ; Blamey, Peter J. ; Mecklenburg, Dianne J. ; Webb, Robert L. ; Pyman, Brian C. ; Franz, Burkhard K. ( 1987)
    The preliminary results from this study indicate that some prelingually deaf patients may get worthwhile help from a multiple-electrode cochlear implant that uses a formant-based speech processing strategy. It is encouraging that these improvements can occur in young adults and teenagers. The results for two children are also encouraging. A 10-year-old child obtained significant improvement on some speech perception tests. It was easy to set thresholds and comfortable listening levels on a 5-year-old child, and he is now a regular user of the device. There are, however, considerable variations in performance among the prelingual patients, which may be related to the following factors: whether they have had some hearing after birth, the method of education used, the motivation of the patient, and age at implantation.
  • Item
    Thumbnail Image
    A multiple-electrode intracochlear implant for children
    Clark, Graeme M. ; Blamey, Peter J. ; Busby, Peter A. ; Dowell, Richard C. ; Franz, Burkhard K-H. ; Musgrave, Gaye Nicholls ; Nienhuys, Terry G. ; Pyman, Brian C. ; Roberts, Susan A. ; Tong, Yit C. ; Webb, Robert L. ; Kuzma, Januz A. ; Money, David K. ; Patrick, James F. ; Seligman, Peter M. ( 1987)
    A multiple-electrode intracochlear implant that provides 21 stimulus channels has been designed for use in young children. It is smaller than the adult version and has magnets to facilitate the attachment of the headset. It has been implanted in two children aged 5 and 10 years. The two children both lost hearing in their third year, when they were still learning language. Following implantation, it was possible to determine threshold and comfortable listening levels for each electrode pair. This was facilitated in the younger child by prior training in scaling visual and electrotactile stimuli. Both children are regular users of the implant, and a training and assessment program has been commenced.
  • Item
    Thumbnail Image
    Audiological assessment of profoundly hearing-impaired children
    Busby, P. A. ; Dowell, R. C. ; Nienhuys, T. G. ; Clark, Graeme M. ( 1987)
    The design of an audiological assessment protocol for profoundly hearing-impaired children may be divided into three areas. First, accurate estimation of hearing loss includes the behavioral measures of unaided and aided thresholds and the objective measures of electrocochleography and auditory brain stem response. The reliability of these measures for the accurate diagnosis of a profound to total hearing loss is discussed. Second, speech perception includes the measure of perception in the audition alone, vision alone, and audition plus vision conditions. Test material should include speech features, words, and sentences. Factors influencing the choice of material are the developmental age of the child, the method of educational instruction, speech and language skills, and vocabulary limits. Third, psychophysical properties of residual auditory skills include measures such as frequency, intensity, and duration difference limens. These skills may be compared to those elicited through other sensory channels, such as visual and tactile. Other important factors that should be considered are the psychological well-being of the child and family, family motivations and expectations, and educational requirements.
  • Item
    Thumbnail Image
    Underlying dimensions and individual differences in auditory, visual, and auditory-visual vowel perception by hearing-impaired children
    Busby, P.A. ; Tong, Y. C. ; Clark, Graeme M. ( 1984)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Psychophysical studies for two multiple-channel cochlear implant patients
    Tong, Y. C. ; Clark, Graeme M. ; Blamey, P. J. ; Busby, P. A. ; Dowell, R. C. ( 1982)
    Abstract not available due to copyright.