  • Item
    Thumbnail Image
    A multiple-channel cochlear implant: an evaluation using nonsense syllables
    Clark, Graeme M. ; Tong, Yit Chow ; Martin, Lois F. ; Busby, Peter A. ; Dowell, Richard C. ; Seligman, Peter M. ; Patrick, James F. ( 1981)
    A study using nonsense syllables has shown that a multiple-channel cochlear implant with speech processor is effective in providing information about, voicing and manner and to a lesser extent place distinctions. These distinctions supplement lipreading cues. Furthermore, the average percentage improvements in overall identification scores for multiple-channel electrical stimulation and lipreading compared to lipreading alone were 71% for a laboratory-based speech processor and 122 % for a wearable unit.
  • Item
    Thumbnail Image
    A multiple-channel cochlear implant: an evaluation using an open-set word test
    Clark, Graeme M. ; Tong, Y. C. ; Martin, L. F. ; Busby, P. A. ( 1981)
    Multiple-channel electrical stimulation of the hearing nerve in conjunction with speech reading has helped two post-lingually deaf patients with total hearing losses understand running speech in every day situations. This has been confirmed using open-set phonetically balanced word tests, where the patients achieved 60% and 40% scores with isolated-words and 80% and 73% for phonemes-in-isolated words. The tests also showed that the cochlear implant improved word recognition by a factor of four in one patient and two in another compared with speechreading alone. The speech processor used extracted the voicing frequency and energy and the frequency and energy of the dominant spectral peak in the mid-frequency range. The parameters for voicing determined the rate of stimulation for all electrodes, and the parameters for the dominant spectral peak in the midfrequency range determined the site of electrode stimulation and current level.
  • Item
    Thumbnail Image
    Results for two children using a multiple-electrode intracochlear implant
    Busby, P. A. ; Tong, Yit C. ; Roberts, S. A. ; Altidis, P. M. ; Dettman, S. J. ; Blamey, Peter J. ; Clark, Graeme M. ; Watson, R. K. ; Rickards, Field W. ( 1989)
    Abstract not available due to copyright.
  • Item
  • Item
    Thumbnail Image
    The University of Melbourne/Nucleus cochlear prosthesis
    Clark, Graeme M. ; Blamey, P. J. ; Brown, A. M. ; Busby, P. A. ; Dowell, R. C. ; Franz, B. K-H. ; Millar, J. B. ; Pyman, B. C. ; Shepherd, R. K. ; Tong, Y. C. ; Webb, R. L. ; Brimacombe, J. A. ; Hirshorn, M. S. ; Kuzma, J. ; Mecklenburg, D. J. ; Money, D. K. ; Patrick, J. F. ; Seligman, P. M. ( 1988)
    This is a review of research to develop the University of Melbourne/Nucleus cochlear prosthesis for patients with a profound-total hearing loss. A more complete review can be obtained in Clark et al. A prototype receiver-stimulator and multiple-electrode array developed at the University of Melbourne was first implanted in a postlingually deaf adult patient with a profound-total hearing loss on 1 August 1978. A speech processing strategy which could help this patient understand running speech, especially when combined with lipreading was developed in 1978 following initial psychophysical studies. A prototype wearable speech processor was fabricated in 1979, that could provide significant help for the first two patients in understanding running speech when used in combination with lipreading compared with lipreading alone, and it also enabled them to understand some running speech when using electrical stimulation alone. An implantable receiver-stimulator and wearable speech processor embodying the principles of the prototype devices were then produced for clinical trial by the Australian biomedical firm, Nucleus Ltd, and its subsidiaries, Cochlear Pty Ltd and Cochlear Corporation. This cochlear implant was initially clinically trialled on six patients at The Royal Victorian Eye & Ear Hospital in 1982, and shown to give similar results to those obtained with the prototype device. In view of these findings a clinical trial was carried out for a Premarket Approval Application to the US Food and Drug Administration (FDA), and extended to a number of centres in the US, Canada, and West Germany. This clinical trial confirmed that patients could understand running speech when electrical stimulation was combined with lipreading, and that some patients could also understand running speech when using electrical stimulation alone. Today, more than 600 patients world-wide are using cochlear implants developed from the research described in this paper.
  • Item
    Thumbnail Image
    Underlying structure of auditory-visual consonant perception by hearing-impaired children and the influences of syllabic compression
    Busby, P. A. ; Tong, Y. C. ; Clark, Graeme M. ( 1988)
    The identification of consonants in /a/-C-/a/ nonsense syllables, using a fourteen-alternative forced-choice procedure, was examined in 4 profoundly hearing-impaired children under five conditions: audition alone using hearing aids in free-field (A), vision alone (V), auditory-visual using hearing aids in free-field (AV1), auditory-visual with linear amplification (AV2), and auditory-visual with syllabic compression (AV3). In the AV2 and AV3 conditions, acoustic signals were binaurally presented by magnetic or acoustic coupling to the subjects' hearing aids. The syllabic compressor had a compression ratio of 10:1, and attack and release times were 1.2 ms and 60 ms. The confusion matrices were subjected to two analysis methods: hierarchical clustering and information transmission analysis using articulatory features. The same general conclusions were drawn on the basis of results obtained from either analysis method. The results indicated better performance in the V condition than in the A condition. In the three AV conditions, the subjects predominately combined the acoustic parameter of voicing with the visual signal. No consistent differences were recorded across the three AV conditions. Syllabic compression did not, therefore, appear to have a significant influence on AV perception for these children. A high degree of subject variability was recorded for the A and three AV conditions, but not for the V condition.
  • Item
    Thumbnail Image
    A multiple-electrode intracochlear implant for children
    Clark, Graeme M. ; Blamey, Peter J. ; Busby, Peter A. ; Dowell, Richard C. ; Franz, Burkhard K-H. ; Musgrave, Gaye Nicholls ; Nienhuys, Terry G. ; Pyman, Brian C. ; Roberts, Susan A. ; Tong, Yit C. ; Webb, Robert L. ; Kuzma, Januz A. ; Money, David K. ; Patrick, James F. ; Seligman, Peter M. ( 1987)
    A multiple-electrode intracochlear implant that provides 21 stimulus channels has been designed for use in young children. It is smaller than the adult version and has magnets to facilitate the attachment of the headset. It has been implanted in two children aged 5 and 10 years. The two children both lost hearing in their third year, when they were still learning language. Following implantation, it was possible to determine threshold and comfortable listening levels for each electrode pair. This was facilitated in the younger child by prior training in scaling visual and electrotactile stimuli. Both children are regular users of the implant, and a training and assessment program has been commenced.
  • Item
    Thumbnail Image
    Audiological assessment of profoundly hearing-impaired children
    Busby, P. A. ; Dowell, R. C. ; Nienhuys, T. G. ; Clark, Graeme M. ( 1987)
    The design of an audiological assessment protocol for profoundly hearing-impaired children may be divided into three areas. First, accurate estimation of hearing loss includes the behavioral measures of unaided and aided thresholds and the objective measures of electrocochleography and auditory brain stem response. The reliability of these measures for the accurate diagnosis of a profound to total hearing loss is discussed. Second, speech perception includes the measure of perception in the audition alone, vision alone, and audition plus vision conditions. Test material should include speech features, words, and sentences. Factors influencing the choice of material are the developmental age of the child, the method of educational instruction, speech and language skills, and vocabulary limits. Third, psychophysical properties of residual auditory skills include measures such as frequency, intensity, and duration difference limens. These skills may be compared to those elicited through other sensory channels, such as visual and tactile. Other important factors that should be considered are the psychological well-being of the child and family, family motivations and expectations, and educational requirements.
  • Item
    Thumbnail Image
    Underlying dimensions and individual differences in auditory, visual, and auditory-visual vowel perception by hearing-impaired children
    Busby, P.A. ; Tong, Y. C. ; Clark, Graeme M. ( 1984)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Psychophysical studies for two multiple-channel cochlear implant patients
    Tong, Y. C. ; Clark, Graeme M. ; Blamey, P. J. ; Busby, P. A. ; Dowell, R. C. ( 1982)
    Abstract not available due to copyright.