    Speech perception, production and language results in a group of children using the 22-electrode cochlear implant
    Blamey, P. J. ; Dawson, P. W. ; Dettman, S. J. ; Rowland, L. C. ; Brown, A. M. ; Busby, P. A. ; Dowell, R. C. ; Rickards, F. W. ; Clark, Graeme M. ( 1992)
    Five children out of a group of nine (aged 5.5 to 19.9 years) implanted with the 22-electrode cochlear implant (Cochlear Ply. Ltd.) have achieved substantial scores on open-set speech tests using hearing without lipreading. Phoneme scores for monosyllabic words ranged from 40% to 72%. Word scores in sentences ranged from 26% to 74%. Four of these five children were implanted during preadolescence. The fifth child, who had a progressive loss and was implanted during adolescence after a short period of very profound deafness, scored highest on all speech perception tests. The remaining four children who did not demonstrate open-set recognition were implanted during adolescence after a long duration of profound deafness. Post-operative performance on closed-set speech perception tests was better than pre-operative performance for all children. Improvements in speech and language assessments were also noted. These improvements tended to be greater for the younger children. The results are discussed with reference to variables which may contribute to successful implant use: such as age at onset, duration of profound hearing loss, age at implantation, aetiology, educational program, and the type of training provided.
  • Item
    Thumbnail Image
    The perception of temporal modulations by cochlear implant patients
    Busby, P. A. ; Tong, Y. C. ; Clark, Graeme M. ( 1993)
    The perception of temporal modulations of pulsatile electric stimuli was measured in seven cochlear implant patients using the Cochlear Pty. Limited prosthesis. Four patients were postlingually deafened adults and three patients were young adults who were deafened very early in life. The first study measured detection thresholds for modulated pulse duration for a series of modulation frequencies and pulse rates. The shape of the detection thresholds as a function of modulation frequency, the temporal modulation transfer function, often resembled a low-pass filter with a 50-100-Hz cut-off frequency. Thresholds did not markedly vary across the different pulse rates for most patients. Thresholds were less than 10%-20% of the range of usable hearingfor most patients. The second study compared detection thresholds for modulated pulse durations around different reference pulse durations: 50, 100, and 300 J.Ls. Detection thresholds were generally proportional to the different reference pulse durations. The third study measured difference limens for the discrimination of modulation depth. The difference limens were similar to the detection thresholds for the same reference pulse duration and pulse rate. The three patients deafened very early in life showed more within-group variation in performance, and their overall levels of performance were poorer than those of the postlingually deafened adults.
  • Item
    Thumbnail Image
    Electrode position, repetition rate, and speech perception by early-and-late-deafened cochlear implant patients
    Busby, P. A. ; Tong, Y. C. ; Clark, Graeme M. ( 1993)
    Psychophysical and speech perception studies were conducted on eight patients using the 22electrode cochlear implant manufactured by Cochlear Pty. Ltd. Four early-deafened patients became deafened at 1-3 years of age and were implanted at 5-14 years of age. Four late-deafened (postlingual adult) patients became deafened at 38-47 years of age and were implanted at 42-68 years of age. Psychophysical studies measured the discrimination of trajectories with time-varying electrode positions and repetition rates. Speech perception studies measured performance using two speech coding strategies: a multi-electrode strategy which coded the first and second formant frequencies, the amplitudes of the two formants, and the fundamental frequency; and a single-electrode strategy which coded the amplitudes of the first and second formants, and the fundamental frequency. In general, the four late-deafened patients and one early-deafened patient were more successful than the other three early-deafened patients in the discrimination of electrode position trajectories and in speech perception using the multi-electrode strategy. Three of the four late-deafened patients were more successful than the early-deafened patients in the discrimination of repetition rate trajectories. Speech perception performance in the single-electrode strategy was closely related to performance in repetition rate discrimination. The improvement in speech perception performance from the single-electrode to multi-electrode strategy was consistent with successful performance in electrode discrimination.
  • Item
    Thumbnail Image
    Psychophysical studies with children using cochlear implants [Abstract]
    Busby, P. ; Blamey, Peter J. ; Tong, Y. ; Clark, Graeme M. ; Dowell, Richard C. ( 1992)
    Psychophysical studies were conducted on a heterogeneous group of 12 patients using, the Cochlear Nucleus cochlear implant. These patients became profoundly deaf early in life, prior to the full development of auditory and speech skills. The aim of the studies was to determine whether the basic hearing skills of these patients differ from those of patients who becamedeaf later in life. The mean age of, the patients at confirmation of the profound hearing loss was 22.3 months (range 6 to 45 months). The mean age of at the time of implantation as 14.8 years (range 5 to 24 years). The cause of deafness was meningitis for 7 patients, congenital Usher's syndrome for 3 patients and congenital unknown for 2 patients.