Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 27
  • Item
    Thumbnail Image
    Pitch and loudness estimation for single and multiple pulse per period electric pulse rates by cochlear implant patients
    Busby, P. A. ; Clark, Graeme M. ( 1997)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Gap detection by early-deafened cochlear-implant subjects
    Busby, P. A. ; Clark, Graeme M. ( 1999)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Modulation detection interference in cochlear implant subjects
    Richardson, Louise M. ; Busby, Peter A. ; Clark, Graeme M. ( 1998)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Studies of prosody perception by cochlear implant patients
    Richardson, Louise M. ; Busby, Peter A. ; Blamey, Peter J. ; Clark, Graeme M. ( 1998)
    Prosodic information is conveyed to normally-hearing listeners by variations in acoustic fundamental frequency, amplitude envelope, and duration of speech segments. This study measured cochlear implant patients' sensitivity to these parameters in electrically coded speech. The psychophysical discrimination of electric parameters used to code prosodic information, were examined, together with prosody perception using speech processing strategies which modified the contributions of these parameters. Patients were implanted with the Cochlear Limited prosthesis and used the MPEAK speech processing strategy. In the psychophysical studies, difference limens were measured for steady-state and time-varying stimuli, of different pulse rates and pulse durations, over a series of different stimulus durations. These limens were obtained using an adaptive procedure which converged on the 50 per cent correct point. In the prosody perception studies, performance was measured for the MPEAK strategy and for strategies which modified the contributions of pulse rate and pulse duration. Data were collected for five tests of prosodic contrasts. Difference limens for steady-state pulse rates were larger at higher rates (17 per cent at 400 pulses/s) than at lower rates (6 per cent at 100 pulses/s). For some patients, limens for the time-varying pulse rates were larger than those for the steady-state pulse rates while for the other patients, the limens were similar. Difference limens for pulse duration were 0.3 dB, corresponding to 4 per cent of the dynamic range, for steady-state stimuli and doubled in size for the time-varying stimuli. Prosody perception performance was generally poorer for the modified strategies than for the MPEAK strategy, suggesting that the removal of information coded by pulse rate and pulse duration reduced the perception of prosodic contrasts.
  • Item
    Thumbnail Image
    A clinical report on speech production of cochlear implant users
    Dawson, P. W. ; Blamey, P. J. ; Dettman, S. J. ; Rowland, L. C. ; Barker, E. J. ; Tobey, E. A. ; Busby, P. A. ; Cowan, R. C. ( 1995)
    Objective: The aim was to assess articulation and speech intelligibility over time in a group of cochlear implant users implanted at 8 yr or over. The hypothesis was that the postoperative speech production performance would be greater than the preoperative performance. Design: A test of intelligibility using sentences and an articulation test measuring non-imitative elicited speech were administered to 11 and 10 subjects, respectively, who were implanted with the 22-electrode cochlear implant. Nine subjects received both tests. Age at implantation ranged from 8 yr to 20 yr and implant use ranged from 1 yr to 4 yr 5 mo. Results: For both the intelligibility and articulation tests roughly half of the subjects showed significant improvements over time and group mean postoperative performance significantly exceeded preoperative performance. Improvements occurred for front, middle, and back consonants; for stops, fricatives, and glides and for voiceless and voiced consonants. Conclusions: Despite being deprived of acoustic speech information for many childhood years, roughly half of the patients assessed showed significant gains in speech intelligibility and articulation postimplantation. The lack of a control group of non-implanted patients means that we cannot separate out the influence of the implant on speech production from other influences such as training and tactile-kinaesthetic feedback.
  • Item
    Thumbnail Image
    Cochlear implant place psychophysics: 1. Pitch estimation with deeply inserted electrodes
    Cohen, Lawrence T. ; Busby, Peter A. ; Whitford, Lesley A. ; Clark, Graeme M. ( 1996)
    Numerical estimation of pitch was performed by 8 adult subjects implanted with cochlear prostheses manufactured by Cochlear Limited. The electrode arrays had been inserted into the scala tympani to between one and one and a half turns of the cochlea. Using bipolar stimulation, the pitch estimates for each subject showed an overall reduction with insertion depth of the stimulated electrode. However, for several subjects, after decreasing regularly for the more basal electrodes, pitch estimates showed an abrupt decrease, followed in some cases by a region of low pitch. Two of the subjects, implanted with a modified electrode array, the '20 + 2' which allowed monopolar in addition to bipolar stimulation, exhibited an abrupt decrease in pitch estimate with bipolar but not with monopolar stimulation. In these two subjects, for stimulating electrodes inserted more deeply than about three quarters of a turn, bipolar stimuli produced lower pitch sensations, and presumably more apical neural excitation patterns, than monopolar stimuli.
  • Item
    Thumbnail Image
    Cochlear implant place psychophysics: 2. Comparison of forward masking and pitch estimation data
    Cohen, Lawrence T. ; Busby, Peter A. ; Clark, Graeme M. ( 1996)
    Results for forward masking and numerical estimation of pitch were compared in a group of 6 adult subjects implanted with cochlear prostheses manufactured by Cochlear Limited. Data were collected for bipolar +1 stimulation in all subjects, and for stimulation in one other mode, either common ground or monopolar, for all subjects but one. The pitch data show various irregularities and in each case can be seen to be broadly consistent with the corresponding forward masking data. It is shown that a 'centre of gravity' of the forward masking distribution varies with masker electrode in a manner that is qualitatively very similar to the variation of pitch estimate. It is suggested that, while pitch estimation results are consistent with those from forward masking, the latter contain more detailed information that may be useful in understanding intersubject variations in speech comprehension.
  • Item
    Thumbnail Image
    The perception of electrodes by cochlear implant patients who became deaf early in life [Abstract]
    BUSBY, PETER ; Clark, Graeme M. ( 1994)
    Two separate studies measuring the perception of differences in site of electrode stimulation were conducted with cochlear implant patients who became deaf early in life. The multiple-electrode prosthesis manufactured by Cochlear Pty. Limited was used. Two of the possible mechanisms for the discrimination of different electrodes are pitch and loudness. The first study measured the discrimination of different electrodes using two procedures which minimised the influences of loudness cues on performance. In the first procedure, the stimulation patterns were symmetric sweeps across electrodes. The reference stimuli were apical-basal trajectories and the comparison stimuli were basal-apical trajectories. The electric stimulation levels were the same in the reference and comparison stimuli because the same electrodes were used in the trajectories. In the second procedure, the stimulation patterns used randomised variations in electric stimulation levels on the different electrodes. By randomly varying the loudness of the stimuli in a discrimination task, the patient is required to listen for more salient cues such as pitch. Both procedures gave comparable results. The second study was concerned with the estimation of order in percepts for stimulation on the different electrodes along the array which was related to the tonotopic order of the cochlea. Approximately half of the early-deafened patients tested revealed a tonotopic order in percepts which was comparable to that obtained from postlinguistically deafened adults.
  • Item
    Thumbnail Image
    A clinical report on speech production of cochlear implant users [Abstract]
    Dawson, P. ; Blamey, P. ; Dettman, S. ; Rowland, L. ; Barker, E. ; Tobey, E. ; Busby, P. ; Cowan, R. ; Clark, Graeme M. ( 1994)
    Speech production results are reported for a group of 15 children, adolescents and prelinguistically deafened adults implanted with the 22-electrode cochlear implant. Age at implantation ranged from 5 years to 20 years and implant experience ranged from 1 year to 4 years, 7 months. On a speech intelligibility test using sentences seven implant users improved significantly over time. Mean group performance (n = 11) improved from 18% preoperatively to 43% postoperatively. Similarly on a test of articulation, eight implant users improved significantly over time and the group mean postoperative performance (n = 11) exceeded the preoperative performance (55% compared to 38%). This group effect was significant for consonants and blends but was nonsignificant for vowels. Improvements occurred for front, middle and back consonants, for stops, nasals, fricatives and glides and for voiceless and voiced consonants. Three implant users showed no significant gain on either test. The results suggest complex relationships between speech production performance and sensory information provided by a multichannel implant.
  • Item
    Thumbnail Image
    Formant frequency values of vowels produced by preadolescent boys and girls
    Busby, P. A. ; Plant, G. L. ( 1995)
    Abstract not available due to copyright.