Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 6 of 6
  • Item
    Thumbnail Image
    Investigations on a curved intracochlear array
    Donnelly, M. J. ; Cohen, L. T. ; Xu, J. ; Xu, S-A. ; Clark, Graeme M. ( 1995)
    The electrode array of a multiple-channel cochlear implant lies against the outer wall of the scala tympani. From this position electrical current spreads to excite residual neural elements, particularly spiral ganglion cells within the modiolus. It is not clear whether the spread of current from the outer wall is optimal for multiple-channel speech processing, but placement closer to the target nerves could result in lower thresholds. This could have benefits through the use of shorter pulse durations and extended battery life. Computer modeling studies and animal experiments have suggested that for localized current the optimal electrode position is adjacent to the modiolus. At the University of Melbourne it was felt that an electrode with a curve matching the internal cochlear spiral would remain close to the modiolus after insertion. A curved electrode was developed and an inserting tool was designed and produced (Treaba et al, this suppl, this section). Preliminary studies suggested that the electrode array did indeed remain close to the modiolus. Before further development of this type of electrode design, it was necessary to determine whether modifications to the surgical technique for its insertion were required. It was also important to ensure that the curved electrode fabricated for clinical trial would lie closer to the modiolus than to the outer wall of the scala tympani. This study was undertaken to examine these issues.
  • Item
    Thumbnail Image
    Initial investigation of the efficacy and biosafety of sodium hyaluronate (healon) as an aid to electrode array insertion
    Donnelly, M. J. ; Cohen, L. T. ; Clark, Graeme M. ( 1995)
    Stimulation of residual neural elements by electrodes inserted into the cochlea to produce the perception of speech and environmental sounds in profoundly deaf people is a fundamental aim of cochlear implantation. The multiple-channel cochlear implant utilizes the tonotopic arrangement of the organ of Corti to also achieve place pitch perception by stimulating different electrode bands. It may be possible to improve the range of pitches perceived by present cochlear implant patients by inserting the electrode array more deeply. To help achieve this, investigators have used sodium hyaluronate as a lubricant for electrode insertions. 1 It was felt deeper insertions were produced with sodium hyaluronate. Before introducing this substance as part of the surgical protocol for the Melbourne Cochlear Implant Clinic, it was decided to investigate its efficacy in aiding deeper insertions of the electrode. In addition, it was also necessary to determine if sodium hyaluronate, in conjunction with cochlear implantation, had adverse effects on the inner ear. This study was undertaken to address these issues.
  • Item
    Thumbnail Image
    A portable programmable digital sound processor for cochlear implant research
    McDermott, Hugh J. ; Vandali, Andrew E. ; van Hoesel, Richard J. M. ; McKay, Colette M ; HARRISON, MARK ; Cohen, Lawrence T. ( 1993)
    A programmable sound processor which utilizes digital signal processing has been developed for hearing prosthesis research. It incorporates a Motorola DSP56001 integrated circuit, 32K words of memory, a 12 b analog-to-digital converter, and a data formatter and transmitter which conveys control codes to the receiver-stimulator of a cochlear implant. The processor is pocket-sized and battery powered. It has been programmed to emulate the Spectral Maxima Sound Processor for the University of Melbourne/Nucleus 22 electrode implant, and is currently being used by several implantees. In continuing research, speech processing programs are being improved, and other applications, including signal processing for binaural implants and advanced hearing aids, are being developed.
  • Item
  • Item
    Thumbnail Image
    Psychophysics and speech perception with a premodiolar electrode array
    Cohen, Lawrence T. ; Clark, Graeme M. ( 1997)
    A perimodiolar electrode array, designed to lie closer to the modiolus than the standard Coclear Limited array and developed by the Cooperative Research Centre for Cochlear Implant, Speech and Hearing Research in conjunction with Cochlear Limited, has recently been implanted in an adult patient. While excellent speech results have been obtained using the standard array, it is hypothesised that the improved place coding expected from an array lying closer to the modiolus would result in improved speech perception. Analysis of a modified Stenvers view X-ray revealed that the most apical electrode was inserted to an angle of 311 0 and that the apical half of the array was considerably closer to the modiolus than would have been the case for a standard array. Thresholds and comfortable levels were correlated with the lateral position of the stimulated electrode in the scala tympani, being much reduced for the apical electrodes. Forward masking and electrode discrimination are being measured in order to study the spread of neural excitation and the distinctness of percepts for different electrodes.
  • Item
    Thumbnail Image
    Steady-state evoked potentials (SSEPS): an accurate, automated, frequency specific method for objectively assessing hearing thresholds [Abstract]
    Burton, Martin J. ; Rance, G. ; Rickards, Field W. ; Cohen, L. T. ; Clark, Graeme M. ( 1992)
    The determination of hearing thresholds in young children and some adults is impossible using conventional behavioural audiometry. The development of objective methods of assessment for use in such patients is highly desirable.