Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 17
  • Item
    Thumbnail Image
    Improved sound processing for cochlear implants
    James, C.J. ; Just, Y. ; Knight, M.R. ; Martin, L.F.A. ; McKay, C.M. ; Plant, K.L. ; Tari, S. ; Vandali, A.E. ; Clark, Graeme M. ; Cowan, R.S.C. ; McDermott, H. J. ; Blamey, P. J. ; Dawson, P. ; Fearn, R. A. ; Grayden, D. B. ; Henshall, K. R. ( 2002)
    Four signal processing schemes currently under development aim to improve the perception of sounds/ especially speech, for children and adults using the Nucleus cochlear implant system. The schemes are (1) fast-acting input-signal compression, (2) Adaptive Dynamic Range Optimisation (ADRO), (3) TESM, a scheme that emphasises transients in signals, and (4) DRSP, a strategy that applies different stimulation rates to selected sets of electrodes.
  • Item
    Thumbnail Image
    A comparative study of phase-contrast and conventional x-ray imaging in human temporal bone samples
    XU, JIN ; TYKOCINSKI, MICHAEL ; Saunders, E. ; Clark, Graeme M. ; Cowan, R. ( 2001)
    This study compared a new x-ray modality, phase-contrast radiography, with conventional radiography for imaging in human temporal bones and also investigated its potential application in the development of electrode arrays for advanced cochlear implants. Nucleus standard electrode arrays and peri-modiolar Contourn.4 electrode arrays were implanted into the cochleae of 10 human temporal bones. Both conventional and phase-contrast radiographs were taken of ~ach temporal bon~. The phase-contrast radiographs showed significant improvements over conventional radiographs in the detail of temporal bone images. These improvements included enhanced contrast at the edge of canal type features, inherent image magnification, higher spatial resolution, and ability to use detectors such as Imaging Plates. The results demonstrate that phase-contrast imaging can have important advantages in visualisation of anatomical details of both the inner ear structures and the microelectrode. It can provide a clearer definition of electrode location in relation to cochlear walls. This study demonstrates the feasibility of applying phase-contrast radiography to studies of the human temporal bone. However, its usefulness in the imaging of larger objects or perhaps even with patients in a clinical setting will require further investigation.
  • Item
    Thumbnail Image
    Application of advanced radiographic technology in cochlear implant research
    XU, JIN ; TYKOCINSKI, MICHAEL ; Saunders, E. ; Clark, Graeme M. ; Cowan, R. ( 2001)
    The effective development of peri-modiolar or other advanced electrode arrays for cochlear implants requires detailed analysis of the insertion procedure and electrode positioning in the cochlea. Routine x-ray techniques cannot provide sufficient detail to meet this need. A new micro-focus x-ray imaging system has been built for our research. The system consists of a x-ray tube with a sub 10-micron focal spot mounted below an adjustable work surface and an image intensifier placed approximately 100 cm above the x-ray aperture. A variety of intracochlear electrode arrays and human temporal bones were studied using this system. The micro-focus x-ray imaging system allows for micro-fluoroscopy to visualise the real time implantation procedure. It also enables capturing of images onto reusable phosphor imaging plates or films for subsequent viewing or analysis. Images are produced at up to 95 times magnification with superior resolution and enhanced contrast. This new radiographic technology plays an important role in development of safe and effective advanced intracochlear electrode arrays.
  • Item
    Thumbnail Image
    Safety studies and preliminary patient trails with a new perimodiolar electrode array
    Clark, Graeme M. ; COWAN, ROBERT ; Saunders, Elaine ; TYKOCINSKI, MICHAEL ; COHEN, LAWRENCE ; Treaba, Claudiu ; BRIGGS, ROBERT ; Dahm, Markus ( 2000)
    A new perimodiolar electrode array, the curly-with stylet (CwS), has been developed and undergone safety trials in human cadaver temporal bones. The array was developed as a result of animal and modelling studies which indicated that there are potential advantages in situating the electrode array in closer proximity to the neural elements. Preliminary studies with four patients in Melbourne implanted with a developmental pre-curved array had supported the predictions of lower current requirements and possibly more focussed spread of excitation.
  • Item
    Thumbnail Image
    What factors contribute to successful outcomes for children using cochlear implants
    Cowan, Robert C. ; Clark, Graeme M. ; Dowell, Richard C. ; Dettman, Shani J ; Barker, Elizabeth ; Latus, Katie ; Hollow, Rod ; Blamey, Peter J. ( 2000)
    Long term speech perception data has been collected for 100 children using the Nucleus multichannel cochlear prosthesis in Melbourne. Scores on a number of different assessments are available at approximately six month intervals following implantation for these children. The group represents an unselected sample of cochlear implant users, as all children were included if they had sufficient developmental skills to perform formal speech perception tests. Information was also collected on each child regarding type of hearing loss, age of onset of profound hearing loss, duration of profound hearing loss, age at implantation, pre and post-implant communication mode, developmental delay, speech processing strategy and length of experience with implant use.
  • Item
    Thumbnail Image
    Hearing levels and speech perception prior to cochlear implantation - are they predictive of outcomes for adult implant users?
    Dowell, Richard C. ; Winton, Elizabeth ; Ling, Caroline ; Hollow, Rod ; COWAN, ROBERT ; Clark, Graeme M. ( 2000)
    As the speech perception results obtained for adults using multichannel cochlear implants have improved, people with a wider range of hearing losses are now considering implantation. In the mid-1980s, most adults undergoing cochlear implantation had little or no residual hearing. This made selection and counselling relatively straightforward as any level of hearing obtained through use of the cochlear implant could be considered as a benefit in such cases. Most patients evaluated for implantation today have some degree of useful residual hearing, and may be reliant on this hearing to varying degrees in their everyday life. In essence, they have something to lose if their postoperative performance is poor. In counselling these patients, it would be most helpful to have reliable predictors of postoperative performance. A number of factors such as duration of profound hearing loss, congenital profound hearing loss, and certain aetiologies (eg, head injury) have shown significant links with outcomes in previous studies.
  • Item
    Thumbnail Image
    How much residual hearing is too much?
    Cowan, R. S. C. ; Dowell, R. C. ; Psarros, C. ; Dettman, S. J. ; Rance, G. ; Clark, Graeme M. ( 2000)
    The value of cochlear implants as an established clinical option for profoundly hearing-impaired adults and children has been supported by significant research results over a number of years (U.S. National Institutes of Health Consensus Statement 1995). As a direct consequence of the level of benefits shown for cochlear implant users on measures of speech perception, research has focused on investigating whether severely hearing impaired adults and children would be suitable candidates for cochlear implantation. I n considering the candidature of any individual, both medical and audiological suitability are investigated. The primary concern is to establish to what degree the patient would benefit from use of the cochlear implant.
  • Item
    Thumbnail Image
    Insertion study using new peri-modiolar electrode array designs [Abstract]
    Treaba, Claudiu ; Clark, Graeme M. ; Cowan, Robert S. ; Tykocinski, Michael J. ; Cohen, Lawrence T. ; Saunders, Elaine ; Pyman, Brian C. ; Briggs, Robert S. ; Dahm, Markus C. ( 1999)
    Intracochlear multi-channel cochlear implants have been shown to successfully provide auditory information for profoundly deaf patients by electrically stimulating discrete populations of auditory nerve fibers via a scala tympani (ST) electrode array. Histological and radiological examination of implanted human temporal bones showed that the current straight Nucleus® array is usually positioned against the outer wall of the ST. An electrode array close to the modiolus could be expected to reduce stimulation thresholds and result in a more localized neural excitation pattern.
  • Item
    Thumbnail Image
    Benefits of pre-curved electrode arrays for the Nucleus multichannel cochlear implant [Abstract]
    Pyman, B. ; Clark, Graeme M. ; Saunders, Elaine ; Cohen, Lawrence T. ; Cowan, Robert S. C. ; Treaba, C. ; Dahm, M. ; Tykocinski, M. ( 1998)
    The purpose of the study was to evaluate whether placement of an electrode closer to the modiolus would provide a more efficient interface with the auditory nerve. A pre-curved, banded 22-electrode array has been developed. Following comprehensive safety studies, the array was inserted in three adult patients. Detailed x-ray analyses have been conducted to specify the positions of the electrode bands. Psychophysical studies have been conducted, within each subject, using electrodes which lie at differing distances from the modiolus. These studies have shown that as the distance from the modiolus decreased, electrode threshold currents decreased and dynamic ranges increased. Thresholds were lower than in a comparison group of standard array users. Forward masking studies showed current spread to be more focused at the electrodes lying closer to the modiolus. Electrode discrimination was also better at electrodes closer to the modiolus. JND for loudness, expressed as a function of dynamic range also decreased in this condition. Thus, a preliminary profile of the parameters of interest, for an improved implant design, suggest that an array which lies closer to the modiolus can result in lower current requirements and a more localised pattern of neural excitation.
  • Item
    Thumbnail Image
    Speech perception & indirect benefits for severely hearing impaired children using cochlear implants [Abstract]
    Cowan, Robert S. C. ; Dowell, Richard C. ; Nott, P. ; Rennie, Maree ; Pyman, B. ; Clark, Graeme M. ( 1998)
    The benefits to speech perception, speech production, communication, and quality of life were investigated for severely hearing impaired children using cochlear implants and hearing aids. For the youngest children, assessments of psychological status, and use of a battery of cognitive and language tests were important factors in determining performance benefits prior to the child developing speech. For older children, the effects of increased one-to-one oral habilitation, and systematic encouragement of parental involvement were also investigated. Results suggested that parental support for consistent device use was an important factor in producing outcomes. Children with residual hearing were more likely to achieve open-set perception. Each child was also assessed for changes in quality of life, through use of a standardized health utility instrument. Results from the group were collated, and teamed with a costing assessment for the procedure, which allowed a complete cost-utility analysis to be completed. Results suggested that indirect benefits, such as the effects on speech production, usual activities, lower concentration, and less distress were ranked as more important than changes to hearing in a number of the children. Costs per QALY were consistent with those reported in the literature, and suggested that the cochlear implant is highly cost-effective as a medical technology.