Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 18
  • Item
    Thumbnail Image
    Contributing factors to improved speech perception in children using the nucleus 22-channel cochlear prosthesis
    Cowan, Robert S. C. ; Galvin, Karyn L. ; KLIEVE, SHARON ; Barker, Elizabeth J. ; Sarant, Julia Z. ; DETTMAN, SHANI ; Hollow, Rod ; RANCE, GARY ; Dowell, Richard C. ; PYMAN, BRIAN ; Clark, Graeme M. ( 1997)
    It has been established that use of multiple-channel intracochlear implants can significantly improve speech perception for postlinguistically deafened adults. In the development of the Nucleus 22-channel cochlear implant, there have been significant developments in speech processing strategies, providing additional benefits to speech perception for users. This has recently culminated in the release of the Speak speech processing strategy, developed from research at the University of Melbourne. The Speak strategy employs 20 programmable bandpass filters which are scanned at an adaptive rate, with the largest outputs of these filters presented to up to ten stimulation channels along the electrode array. Comparative studies of the Speak processing strategy (in the Nucleus Spectra-22 speech processor), with the previously-used Multipeak (Multipeak) speech processing strategy (in the Minisystem-22 speech processor), with profoundly deaf adult cochlear implant users have shown that the Speak processing strategy provides a significant benefit to adult users both in quiet situations and particularly in the presence of background noise. Since the first implantation of the Nucleus device in a profoundly hearing-impaired child in Melbourne in 1985, there has been a rapid growth in the number of children using this device. Studies of cochlear implant benefits for children using the Nucleus 22-channel cochlear implant have also shown that children can obtain significant benefits to speech perception, speech production and language, including open-set understanding of words and sentences using the cochlear implant alone. In evaluating contributing factors to speech perception benefits available for children, four specific factors are important to investigate: (1) earlier implantation -resulting from earlier detection of deafness; (2) improved hardware and surgical techniques -allowing implantation in infants; (3) improved speech processing, and (4) improved habilitation techniques. Results reported previously have been recorded primarily for children using the Multipeak strategy implemented in the MSP speech processor. While it is important to evaluate the factors which might contribute to improvements in speech perception benefits, an important question is the effect of improved speech processing strategy, since this will determine what is perceived through the device. Given that adult patients changing to the Spectra speech processor had also shown improved perception in noisy situations, and the fact that children are in general in noisy environments in the classroom setting for a large proportion of their day, it was of obvious interest to evaluate the potential for benefit in poor signal-to-noise ratios from use of the Speak processing strategy and from specific training in the ability to perceive in background noise. The study was aimed at evaluating whether children who were experienced in use of the Multipeak speech processing strategy would be able to changeover to the new Speak processing strategy, which provides a subjectively different output. Secondly, the study aimed to evaluate the benefits which might accrue to children from use of controlled habilitation in background noise.
  • Item
    Thumbnail Image
    A clinical report on receptive vocabulary skills in cochlear implant users
    Dawson, P. W. ; Blamey, P. J. ; Dettman, S. J. ; Barker, E. J. ; Clark, Graeme M. ( 1995)
    Objective: The aim was to measure the rate of vocabulary acquisition for cochlear implant users and compare the pre- and postoperative rates with published data for other groups with normal or impaired hearing. The hypothesis was that the postoperative rate would be greater than the preoperative rate. Design: The Peabody Picture Vocabulary Test (PPVT) was administered to 32 children, adolescents, and prelinguistically deafened adults implanted with the 22-electrode cochlear implant. Age at implantation ranged from 2 y r 6 mo to 20 yr and implant use ranged from 6 mo to 7 yr 8 mo. Results: The group mean postoperative performance at various postoperative intervals was significantly higher than mean preoperative performance. Single-subject data indicated statistically significant gains over time on this test for 13 of the subjects. The mean postoperative rate of vocabulary acquisition of 1.06 times the rate for normally hearing children was significantly greater than the mean preoperative rate of 0.43. Conclusions: These rates of improvement were in accord with previous reports on smaller numbers of implant users, but could not be attributed unambiguously to use of the implant because no control group was used for this clinical work. Variables such as age at implantation, duration of profound deafness, communication mode, and speech perception skill failed to significantly predict rate of improvement on the PPVT.
  • Item
    Thumbnail Image
    A clinical report on speech production of cochlear implant users
    Dawson, P. W. ; Blamey, P. J. ; Dettman, S. J. ; Rowland, L. C. ; Barker, E. J. ; Tobey, E. A. ; Busby, P. A. ; Cowan, R. C. ( 1995)
    Objective: The aim was to assess articulation and speech intelligibility over time in a group of cochlear implant users implanted at 8 yr or over. The hypothesis was that the postoperative speech production performance would be greater than the preoperative performance. Design: A test of intelligibility using sentences and an articulation test measuring non-imitative elicited speech were administered to 11 and 10 subjects, respectively, who were implanted with the 22-electrode cochlear implant. Nine subjects received both tests. Age at implantation ranged from 8 yr to 20 yr and implant use ranged from 1 yr to 4 yr 5 mo. Results: For both the intelligibility and articulation tests roughly half of the subjects showed significant improvements over time and group mean postoperative performance significantly exceeded preoperative performance. Improvements occurred for front, middle, and back consonants; for stops, fricatives, and glides and for voiceless and voiced consonants. Conclusions: Despite being deprived of acoustic speech information for many childhood years, roughly half of the patients assessed showed significant gains in speech intelligibility and articulation postimplantation. The lack of a control group of non-implanted patients means that we cannot separate out the influence of the implant on speech production from other influences such as training and tactile-kinaesthetic feedback.
  • Item
    Thumbnail Image
    Speech perception for children with different levels of residual hearing using the cochlear 22-channel cochlear prosthesis [Abstract[
    Cowan, R. S. C. ; Galvin, K. L. ; Barker, E. J. ; Del Dot, J. ; Sarant, J. Z. ; Dettman, S. ; Hollow, R. ; Herridge, S. ; Rance, G. ; Larratt, M. ; Skok, M. ; Dowell, R. C. ; Pyman, B. ; Gibson, W. P. R. ; Clark, Graeme M. ( 1996)
    Over the past 10 years, since the implantation of the first children with the Nucleus 22-channel cochlear prosthesis in Melbourne, the number of profoundly deaf children using this implant system has rapidly expanded. Longer-term experience with implanted children has led to improvements in paediatric assessment and management. Speech processing strategies have also been improved, resulting in a series of increases in speech perception benefits. Results of comparative studies of Speak and Multipeak speech processing strategies have shown that open-set word and sentence scores for a group of thirteen children evaluated over a two year period showed an advantage with the Speak speech processing strategy. The increases were noted particularly in speech perception in poor signal-to-noise conditions. Analysis has shown that consonant perception was significantly increased, due to an improved place perception. Given current speech perception scores for implanted children, it has been suggested that severely-to-profoundly deaf children currently using hearing aids could in fact benefit more from a cochlear implant. Preliminary investigation of results for children in the Melbourne and Sydney cochlear implant programs has shown that children with higher levels of preoperative residual hearing as a group do score significantly on open-set word and sentence perception tests using the implant alone. In children with lower levels of residual hearing, results were variable across the group.
  • Item
    Thumbnail Image
    Vowel imitation task: results over time for 28 cochlear implant children under the age of eight years
    Dettman, S. J. ; Barker, E. J. ; Dowell, R. C. ; Dawson, P. W. ; Blamey, P. J. ; Clark, Graeme M. ( 1995)
    With increasing numbers of implanted children under the age of 4 years, numerous researchers have reminded us of the need for valid, sensitive, and reliable tests of developing speech perception.1,2 In addition to studies of the efficacy of implanted prostheses, there is a need to investigate the many variables that influence children's communicative performance, such as changes in speech-coding strategy, updated speech-processing systems, the effects of various training regimens, and the selection of educational and communication modes.
  • Item
    Thumbnail Image
    Results for children and adolescents using the multichannel cochlear prosthesis [Abstract]
    Dowell, Richard C. ; Clark, Graeme M. ; Dettman, Shani J. ; Dawson, Pamela W. ( 1992)
    The first adolescent to use the 22-electrode cochlear prosthesis was Implanted In Melbourne in 1985 and the first child (less than 10 years), the following year. Since then, over 100 children have received the cochlear prosthesis in Australia and over 1200 worldwide. Detailed assessment of 200 children in the U.S.A., Australia and Germany lead to the market approval of the prosthesis by the U.S. Food and Drug Administration in July 1990. The analysis of results for these children has proven to be difficult due to the use of different tests in different places, the lack of appropriate assessment tools for young children, the wide range of performance, and the problems of cooperation for young children. Despite these problems, some trends are beginning to emerge in the speech perception results for implanted children. Children with a greater amount of auditory experience before becoming profoundly deaf tend to perform better, as do children with more experience with the cochlear prosthesis. Those with a greater number of electrodes in use also perform better, a result supported by adult studies. Although older prelinguistically deafened children do not perform as well as postlinguistically deafened adults, there appears to be little difference between results for pre-and post-linguistically deafened young children. These trends In speech perception results will be discussed in more detail.
  • Item
    Thumbnail Image
    Speech perception, production and language results in a group of children using the 22-electrode cochlear implant
    Blamey, P. J. ; Dawson, P. W. ; Dettman, S. J. ; Rowland, L. C. ; Brown, A. M. ; Busby, P. A. ; Dowell, R. C. ; Rickards, F. W. ; Clark, Graeme M. ( 1992)
    Five children out of a group of nine (aged 5.5 to 19.9 years) implanted with the 22-electrode cochlear implant (Cochlear Ply. Ltd.) have achieved substantial scores on open-set speech tests using hearing without lipreading. Phoneme scores for monosyllabic words ranged from 40% to 72%. Word scores in sentences ranged from 26% to 74%. Four of these five children were implanted during preadolescence. The fifth child, who had a progressive loss and was implanted during adolescence after a short period of very profound deafness, scored highest on all speech perception tests. The remaining four children who did not demonstrate open-set recognition were implanted during adolescence after a long duration of profound deafness. Post-operative performance on closed-set speech perception tests was better than pre-operative performance for all children. Improvements in speech and language assessments were also noted. These improvements tended to be greater for the younger children. The results are discussed with reference to variables which may contribute to successful implant use: such as age at onset, duration of profound hearing loss, age at implantation, aetiology, educational program, and the type of training provided.
  • Item
    Thumbnail Image
    Results for two children using a multiple-electrode intracochlear implant
    Busby, P. A. ; Tong, Yit C. ; Roberts, S. A. ; Altidis, P. M. ; Dettman, S. J. ; Blamey, Peter J. ; Clark, Graeme M. ; Watson, R. K. ; Rickards, Field W. ( 1989)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    How much residual hearing is too much?
    Cowan, R. S. C. ; Dowell, R. C. ; Psarros, C. ; Dettman, S. J. ; Rance, G. ; Clark, Graeme M. ( 2000)
    The value of cochlear implants as an established clinical option for profoundly hearing-impaired adults and children has been supported by significant research results over a number of years (U.S. National Institutes of Health Consensus Statement 1995). As a direct consequence of the level of benefits shown for cochlear implant users on measures of speech perception, research has focused on investigating whether severely hearing impaired adults and children would be suitable candidates for cochlear implantation. I n considering the candidature of any individual, both medical and audiological suitability are investigated. The primary concern is to establish to what degree the patient would benefit from use of the cochlear implant.
  • Item
    Thumbnail Image
    Speech perception in implanted children: effects of speech processing strategy and residual hearing
    Meskin, T. ; Rance, G. ; Cody, K. ; Sarant, J. ; Larratt, M. ; Latus, K. ; Hollow, R. ; Rehn, C. ; Dowell, R.C. ; Pyman, B. ; Gibson, W.P.R. ; Clark, Graeme M. ; Cowan, Robert S. C. ; Barker, E. J. ; Pegg, P. ; Dettman, S. ; Rennie, M. ; Galvin, K. (Mendoza Editor, 1997)
    The ability of implanted children to adapt to different speech processing strategies has been demonstrated for the Nucleus implant system. Children previously experienced with the Multipeak speech processing strategy. were able to gain significant improvements in consonant, word and sentence perception using the Speak speech processing strategy. suggesting some degree of neural plasticity in neural-auditory coding. Of 192 implanted children with different degrees of preoperative residual hearing, 65% were found to obtain significant scores on open-set speech materials using electrical stimulation alone. Those children with more residual hearing had a greater probability of achieving open-set understanding and at a minimum level, perceived high frequency consonant information which would not have been available through conventional hearing aids.