Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 14
  • Item
    Thumbnail Image
    Speech perception results for children with implants with different levels of preoperative residual hearing
    Cowan, Robert S. C. ; DelDot, J. ; Barker, J. Z. ; Barker, Elizabeth J. ; Sarant, Julia Z. ; Pegg, P. ; Dettman, S. ; Galvin, K. L. ; Rance, G. ; Hollow, R. ; Dowell, R. C. ; Pyman, B. ; Gibson, W. P. R. ; Clark, Graeme, M. ( 1997)
    Objective: Many reports have established that hearing-impaired children using the Nucleus 22 channel cochlear implant may show both significant benefits to lipreading and significant scores on open-set words and sentences using electrical stimulation only. These findings have raised questions about whether severely or severely-to-profoundly deaf children should be candidates for cochlear implants. To study this question, postoperative results for implanted children with different levels of preoperative residual hearing were evaluated in terms of speech perception benefits. Study Design/Setting: A retrospective study of the first 117 children, sequentially, to undergo implantation in the Melbourne and Sydney Cochlear Implant Clinics was undertaken. All children had been assessed by and received their implants in a tertiary referral centre. Main Outcome Measures: To assess aided residual hearing, the children were grouped into four categories of hearing on the basis of their aided residual hearing thresholds measured preoperatively. To assess benefits, the scores of children on standard speech perception tests were reviewed. As different tests were used for children with different ages and language skills, children were grouped into categories according to the level of postoperative speech perception benefit. Results: The results showed that children in the higher categories of aided preoperative residual hearing showed significant scores on open-set word and sentence perception tests using the implant alone. For children in lower categories of aided residual hearing, results were variable within the groups. More than 90% of children with implants with aided residual hearing thresholds in the speech range above I kHz achieved open-set understanding of words and sentences. Conclusion: While the results of this preliminary study confirm previous findings of differential outcomes for children with different levels of preoperative residual hearing, they suggest that children with severe to profound hearing impairments should be considered for cochlear implantation.
  • Item
    Thumbnail Image
    Assessment of intracochlear ossification by three-dimensional reconstruction of computerised scans
    Pyman, B. C. ; Seldon, H. L. ; O'Sullivan, R. ; Tillner, W. D. ; Donnelly, M. ; Scott, M. ; Mack, K. F. ; Clark, Graeme M. ( 1995)
    The aim of the study was to investigate whether the three-dimensional (3-D) images from computed tomography (CT) scans of the ears could adequately define the site and extent of new bone in the cochlea, and how these images compared with those created by magnetic resonance imaging (MRI). The patients whose investigations were used in the study were being assessed for a cochlear implant and were selected on the basis of their history and the appearance of their two-dimensional (2-D) CT scans. Four patients had progressive mixed deafness, a family history of deafness, and stapedectomies. They were considered to be deaf from otosclerosis and needed further assessment because their scans showed either obstructed cochleas from new bone, or demineralized otic capsules to the point that we could not determine whether new bone was present or not. The fifth patient was being assessed within 3 months of suffering deafness from meningitis. In one ear he had extensive ossification, and in the other the degree of opacification shown in axial and coronal cuts of the basal turn was inconsistent. Essentially the problem is that at the magnification used in examination of the inner ear, the resolution of 2-D CT scans gives indistinct borders between bone and water. Magnetic resonance imaging has commonly been used in these cases. The study showed that it is now possible to confirm whether or not there is new bone and to demonstrate the site and extent of new bone with both 3-D and MRI images. It is not possible to give a degree of sensitivity and specificity for this observation because of the small group of subjects in the study. It should be worth applying the reconstruction software to scans from helical scanners with a view to assessing whether the resolution of the 3-D images can be improved further.
  • Item
    Thumbnail Image
    Continuing improvements in speech processing for adult cochlear implant patients
    Hollow, R. D. ; Dowell, R. C. ; Cowan, R. S. C. ; Skok, M. C. ; Pyman, B. C. ; Clark, Graeme M. ( 1995)
    The Cochlear 22-channel cochlear implant has employed a succession of improved speech-processing strategies since its first use in an adult patient in Melbourne in 1982. 1 The first patients received the F0F2 coding strategy developed by the University of Melbourne, in the Wearable Speech Processor (WSP). The F0F2 coding scheme presented the implant user with three acoustic features of speech. These were 1) the amplitude of the waveform, presented as the amount of current charge, 2) fundamental frequency (F0) or voice pitch, presented as rate of biphasic pulsatile stimulation, and 3) the spectral range of the second formant frequency (F2), which was represented by varying the site of stimulation along the electrode array.
  • Item
    Thumbnail Image
    The progress of children using the multichannel cochlear implant in Melbourne
    Cowan, R. S. C. ; Dowell, R. C. ; Hollow, R. ; Dettman, S. J. ; Rance, G. ; Barker, E. J. ; Sarant, J. Z. ; Galvin, K. L. ; Webb, R. C. ; Pyman, B. C. ; Cousins, V. C. ; Clark, Graeme M. ( 1995)
    Multi-channel cochlear implantation in children began in Australia in 1985 and there are now close to 4000 profoundly deaf children and adolescents using the Australian implant system around the world. The aim of the implant procedure is to provide adequate hearing for speech and language development through auditory input. This contrasts with the situation for adults with acquired deafness where the cochlear implant aims to restore hearing for someone with well-developed auditory processing and language skills. As with adults, results vary over a wide range for children using the Multi-channel implant. Many factors have been suggested that may contribute to differences in speech perception for implanted children. In an attempt to better understand these factors, the speech perception results for children implanted in Melbourne were reviewed and subjected to statistical analysis. This has indicated that the amount of experience with the implant and the length of sensory deprivation are strongly correlated with perceptual results. This means that younger children are likely to perform better with an implant and that a number of years of experience are required for children to reach their full potential. The results have also indicated that educational placement and management play a crucial role in children reaching their potential. Overall, 60% of the children and adolescents in the study have reached a level of open-set speech understanding using the cochlear implant without lipreading.
  • Item
    Thumbnail Image
    Enhancement of the radiographic changes in the otic capsule and cochlea due to otosclerosis using three dimensional reconstruction of CT scans
    Pyman, B. C. ; Seldon, H. L. ; Clark, Graeme M. ( 1995)
    The otic capsule changes of cochlear otosclerosis are occasionally such that standard high resolution CT scans are not clear enough to determine the significance of edge blurring as a predictive factor for implantation. The use of a software package to produce three dimensional enhancement of the CT images has resolved some of these difficulties in specific cases.
  • Item
    Thumbnail Image
    Intracochlear factors contributing to psychophysical percepts following cochlear implantation: a case study
    Kawano, A. ; Seldon, H. L. ; Pyman, B. ; Clark, Graeme M. ( 1995)
    It is conceivable that the variations of performance of cochlear implant patients can be related to several factors. Shiroma et al 1 investigated which factors contributed to the speech recognition ability of cochlear implant patients; multiple regression analysis showed that postoperative psychophysical percepts such as threshold level (T level), maximum comfortable loudness level (C level), and dynamic ranges (DR) may play an important role in speech recognition ability. In this paper, we focus on determining which intracochlear factors contribute to these postoperative psychophysical percepts of the 22-channel cochlear implant system. We made a three-dimensional (3-D) computer reconstruction 2 from the temporal bone of a cochlear implant patient and measured the following factors: distance between the electrode ring's center and the Rosenthal's canal center (dis); the cross-sectional areas of loose and dense fibrous tissue (lft, dft), their sum, fibrous tissue (ft), and new bone (nb) as inner ear pathologic changes; and the density of residual spiral ganglion cells (sgc). The interrelationship between the postoperative psychophysical percepts and these factors is analyzed and discussed.
  • Item
    Thumbnail Image
    Anatomic and surgical considerations in the design of a new receiver-stimulator suitable for implantation in young children
    Pyman, B. C. ; Clark, Graeme M. ( 1995)
    The anatomy of the temporal bone was studied to determine the optimal shape and dimensions of a new receiver-stimulator for use in young children even less than 12 months of age. There was a need to make the receiver-stimulator electronic package smaller so that it could be placed within the mastoid cavity, and the antenna wider, for more efficient power and data transmission. The antenna needed to conform to the smaller radius of a young child's skull. Anatomic dissections were carried out on skulls of children from 3 to 11 months of age to establish the variations in dimensions relevant for implantation. Prototype implant designs were evaluated in these skulls and it was found that the maximum thickness the anterior section of the receiver-stimulator should be was 5.5 mm, and its maximum width, 18 mm. It was found that a prototype electronics package with these dimensions could be fitted comfortably into the average skull of an 8-month-old child. A particular constraint was the depth of the bone over the sigmoid sinus and middle fossa. The radius of curvature of the skull of young children also required the package to be bent in its center at an angle of 160°.
  • Item
    Thumbnail Image
    Chronic middle ear disease and cochlear implantation
    Donnelly, M. J. ; Pyman, B. C. ; Clark, Graeme M. ( 1995)
    Profound or total hearing loss can occur in the setting of chronic suppurative otitis media (CSOM), either coincidentally or secondary to the disease process. Obviously, inserting a foreign body through a potentially infected field into a space that communicates intracranially presents a challenging management problem. This paper presents the experience from the Melbourne Cochlear Implant Clinic (CIC) in implanting patients with bilateral CSOM. This is certainly not a common problem, as there have been only 3 cases from 121 implanted adults. However, we feel that it is an important issue with potentially devastating consequences. In addition, there are many countries in which bilateral CSOM is a more common problem and cause of profound or total hearing loss.
  • Item
    Thumbnail Image
    Surgical considerations for the placement of the new Cochlear Pty Limited micro-multiple-channel cochlear implant for research studies
    Clark, Graeme M. ; Pyman, B. C. ; Webb, R. L. ( 1995)
    A new micro-receiver-stimulator for research studies on very young children as well as adults has been developed by Cochlear Pty Limited. The dimensions of the device are length 58 mm and width at front 18 mm. The width starts to increase 19 mm from the front, and the back section, which has the receiver coil and magnet, has a maximum diameter of 33 mm. The depth or thickness of the front portion of the electronic package is 5.7mm, and the remainder of the package 4.0 mm. The antenna section is 3.5 mm thick. The other dimensions of the front section of the electronic package are length 9.5 mm and width 13.7 mm. There is an angle of 160° between the titanium electronic package and the receiver coil. The dimensions of the receiver-stimulator were arrived at after anatomic studies on the temporal bones of children ranging in age from 2 to 11 months.
  • Item
    Thumbnail Image
    Cochlear pathology following reimplantation of a multichannel scala tympani electrode array in the macaque
    Shepherd, Robert K. ; Clark, Graeme M. ; Xu, Shi-Ang ; Pyman, Brian C. ( 1995)
    The histopathologic consequence of removing and reimplanting intracochlear electrode arrays on residual auditory nerve fibers is an important issue when evaluating the safety of cochlear prostheses. The authors have examined this issue by implanting multichannel intracochlear electrodes in macaque monkeys. Macaques were selected because of the similarity of the surgical technique used to insert electrodes into the cochlea compared to that in humans, in particular the ability to insert the arrays into the upper basal turn. Five macaques were bilaterally implanted with the Melbourne/Cochlear banded electrode array. Following a minimum implant period of 5 months, the electrode array on one side of each animal was removed and another immediately implanted. The animals were sacrificed a minimum of 5 months following the reinsertion procedure, and the cochleas prepared for histopathologic analysis. Long-term implantation of the electrode resulted in a relatively mild tissue response within the cochlea. Results also showed that inner and outer hair cell survival, although significantly reduced adjacent to the array, was normal in 8 of the 10 cochleas apicalward. Moreover, the electrode reinsertion procedure did not appear to adversely affect this apical hair cell population. Significant new bone formation was frequently observed in both control and reimplanted cochleas close to the electrode fenestration site and was associated with trauma to the endosteum and/or the introduction of bone chips into the cochlea at the time of surgery. Electrode insertion trauma, involving the osseous spiral lamina or basilar membrane, was more commonly observed in reimplanted cochleas. This damage was usually restricted to the lower basal turn and resulted in a more extensive ganglion cell loss. Finally, in a number of cochleas part of the electrode array was located within the scala media or scala vestibuli. These electrodes did not appear to evoke a more extensive tissue response or result in more extensive neural degeneration compared with electrodes located within the scala tympani. In conclusion, the present study has shown that the reimplantation of a multichannel scala tympani electrode array can be achieved with minimal damage to the majority of cochlear structures. Increased insertion trauma, resulting in new bone formation and spiral ganglion cell loss, can occur in the lower basal turn in cases where the electrode entry point is difficult to identify due to proliferation of granulation and fibrous tissue.