Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 9 of 9
  • Item
    Thumbnail Image
    Chronic electrical stimulation of the auditory nerve at high rates: I. Effect on residual hearing [Abstract]
    Xu, J. ; Shepherd, R. K. ; Clark, Graeme M. ( 1996)
    In addition to direct excitation of auditory nerve fibres, cochlear implant patients with small amounts of residual hearing may receive important additional auditory cues via electrophonic activation of hair cells 1. Before incorporating electrophonic hearing into speech processing strategies, the extent of hair cell survival following cochlear implantation must first be determined. We have recently demonstrated widespread survival of hair cells apical to electrode arrays implanted for periods of up to three years, the present report describes the effects of chronic electrical stimulation on hair cell survival.
  • Item
    Thumbnail Image
    Chronic electrical stimulation of the auditory nerve at high rates: II. Cochlear pathophysiology [Abstract]
    Shepherd, R. K. ; Xu, J. ; Clark, Graeme M. ( 1996)
    A major factor in the improved performance of cochlear implant patients has been the use of high stimulus rate speech processing strategies. While these strategies show clear clinical advantage, we know little of their long-term safety. Indeed, recent studies have indicated that high stimulus rates at intensities above clinical limits, can result in neural damage as a result of prolonged neuronal hyperactivity. The present study was designed to evaluate the effects of chronic electrical stimulation of the auditory nerve at high rates, using intensities within clinical limits.
  • Item
    Thumbnail Image
    Cochlear implantation in young children: histological studies on head growth, leadwire design, and electrode fixation in the monkey model
    Burton, M. J. ; Shepherd, R. K. ; Xu, S. A. ; Xu, J. ; Franz, B. K-H. G. ; Clark, Graeme M. ( 1994)
    For safe cochlear implantation in children under 2 years of age, the implant assembly must not adversely affect adjacent tissues or compromise head growth. Furthermore, growth changes and tissue responses should not impair the function of the device. Dummy receiver-stimulators, interconnect plugs, and leadwire-lengthening systems were implanted for periods of 36 months in the young monkey to effectively model the implantation of the young child. The results show that implanting a receiver-stimulator package has no adverse effects on skull growth or the underlying central nervous system. The system for fixing the electrode at the fossa incudis proved effective. There was marked osteoneogenesis in the mastoid cavity, resulting in the fixation of the leadwire outside the cochlea. This study provides evidence for the safety of cochlear implantation in young subjects.
  • Item
    Thumbnail Image
    Paediatric cochlear implantation: radiologic observations of skull growth
    XU, JIN ; Shepherd, Robert K. ; Xu, Shi-Ang ; Seldon, H. Lee ; Clark, Graeme M. ( 1993)
    We investigated the effects of long-term implantation of auditory prostheses on skull growth in young animals. Four monkeys were implanted with dummy cochlear implants at 6 months of age. To simulate implantation in children, the bed for the receiver-stimulator or interconnecting plug was drilled across a calvarial suture down to the underlying dura. Plain skull oentgenograms were periodically taken to monitor head growth for up to 3 years after implantation. These longitudinal measurements revealed no significant asymmetric skull growth. Postmortem measurements using computed tomographic scans confirmed these results and showed no significant difference in the intracranial volumes between the implanted and control sides of each animal or between experimental and nonimplanted control monkeys. These results suggest that long-term cochlear implantation in very young children will not cause any significant deformity of the skull.
  • Item
    Thumbnail Image
    Peri-modiolar electrode arrays: a comparison of electrode position n the human temporal bone
    Shepherd, R. K. ; Treaba, C. G. ; Cohen, L. ; Pyman, B. ; Huigen, J. ; Xu, J. ; Clark, Graeme M. (Monduzzi Editore, 1997)
    This paper describes a radiologic evaluation of three types of peri-modiolar arrays, comparing their trajectory within the scala tympani with a standard Mini-22 electrode. All peri-modiolar arrays were found to lie closer to the modiolus for much of their insertion length compared with the standard array. While one design showed evidence for the potential of increased insertion trauma, two designs produced satisfactory results. Although further electrode development, temporal bone and histopathologic studies arE required, it would appear that the benefits of peri-modiolar electrode arrays will be realised clinically.
  • Item
    Thumbnail Image
    Cochlear implants: high rate stimulation studies and the effect of electrode position [Abstract]
    Shepherd, R. K. ; Huang, C. Q. ; Xu, J. ; Tykocinski, M. ; Seligman, P. M. ; Clark, Graeme M. ( 1996)
    This paper summarizes our recent findings investigating the safety of high rate electrical stimulation, and reviews the effects of electrode position on auditory excitability. These studies used charge balanced biphasic pulses and electrode shorting between stimuli to minimize any residual charge or direct current. High rate (400-1000 pulses/s) electrical stimulation of the auditory nerve can result in significant stimulus induced reductions in auditory nerve excitability at stimulus levels well above those used clinically (1). The extent of this reduction was dependent on stimulus rate, intensity and duty cycle, implying that such changes were related to the degree of evoked activity.
  • Item
    Thumbnail Image
    Investigation of curved intracochlear electrode arrays [Abstract]
    Xu, Shi-Ang ; Xu, J. ; Seldon, H Lee. ; Shepherd, R. K. ; Clark, G. M. ( 1992)
    It has been demonstrated that the Melbourne/Cochlear multi-channel cochlear implant is safe and effective for use in profoundly-totally deaf patients. Recent studies have highlighted the importance of deaf insertion and placing the electrodes closer to the spiral ganglion neurons. In order to improve the electrode insertion depth and proximity to the modiolus, we have investigated curved electrode arrays. Prototypes of such arrays and their accessory inserter have been made. Trial insertions were performed on skeletonized cochleae of human temporal bones. The preliminary results showed that, when compared with conventional straight electrode arrays, the curved arrays could be inserted deeper and located closer to the modiolus. These findings indicate that the curved --.~ electrodes currently under investigation should result in a reduction in stimulus threshold and improve pitch perception and may also result in the use of more channels of stimulation.
  • Item
    Thumbnail Image
    Electrical stimulation of the auditory nerve: comparison of half-band with full-band scala tympani bipolar electrodes
    Xu, Shi-Ang ; McAnally, Ken I. ; Xu, J. ; Shepherd, R. K. ; Clark, Graeme M. ( 1993)
    The Melbourne/Cochlear auditory prosthesis uses an intracochlear electrode array containing 22 circumferential full-band electrodes mounted on a Silastic carrier. It could be hypothesized that half-band electrodes, oriented towards the modiolus, would produce lower stimulus thresholds than conventional full-band electrodes. This hypothesis is based on the assumption that, compared with full-band electrodes, half-band electrodes would produce an electrical field in which a greater proportion of the current would excite a defined group of neurons. In order to verify this hypothesis we recorded electrically evoked auditory brainstem responses (EABRs) for both full- and half-band electrodes inserted in the scala tympani of deafened cats. EABR thresholds for half-band electrodes oriented towards the modiolus were not significantly different from thresholds evoked using full-band electrodes (p>0.05, paired t-test), whereas thresholds evoked using half-band electrodes oriented towards the outer scala wall were significantly higher (p<0.01) than either the modiolar half-band or the full-band electrodes. These physiological results suggest that the electrical field generated within the auditory nerve by modiolar oriented half-band electrodes does not differ significantly from that produced by full-band electrodes. On the basis of these results, together with the fact that half-band electrodes would have higher current densities and electrode impedances, and would require careful orientation during implantation, we consider that there is no benefit in incorporating half-band electrodes in the design of scala tympani electrode arrays.
  • Item
    Thumbnail Image
    Cochlear implantation in young children: studies on head growth, leadwire design and electrode fixation in the monkey model [Abstract]
    Burton, Martin J. ; Xu, J. ; Shepherd, R. K. ; Xu, S-A. ; Seldon, H. L. ; Franz, B. K-H. G. ; Clark, Graeme M. ( 1992)
    For the safety of cochlear implantation in children under two, the implant assembly must not adversely effect the tissue of compromise head growth. Furthermore, growth changes and tissue responses should not impair functioning of the device. Dummy receiver-stimulators, interconnect plugs and leadwire-lengthening systems have been implanted for periods of 40 months in the young monkey to most effectively model the implantation of the young human child. The results show that implanting a receiver-stimulator package has no effect on skull growth or brain tissue under the package. The system for fixing the electrode at the fossa includes proved effective. There was marked osteoneogenesis in the mastoid cavity and this also resulted in fixation of the leadwire outside the cochlea. This study provides evidence for the safety of cochlear implantation in young children.