Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 7 of 7
  • Item
    Thumbnail Image
    Cochlear implants in children: the value of cochleostomy seals in the prevention of labyrinthitis following pneumococcal otitis media
    Dahm, M. C. ; Webb, R. L. ; Clark, Graeme M. ; Franz, B. K-H. ; Shepherd, R. K. ; Burton, M. J. ; ROBINS-BROWNE, R. ( 1995)
    Cochlea implantation at an early age is important in rehabilitating profoundly hearing impaired children. Given the incidence of pneumococcal otitis media in young children, there has been concern that cochlear implantation could increase the possibility of otitis media, leading to labyrinthitis in this age group. Clinical experience has not indicated an increase in the frequency of otitis media and labyrinthitis in implanted adults or children over two years. However, labyrinthitis has occurred in implanted animals with otitis media. In order to assess the impact of cochlear implants on the occurrence of labyrinthitis, pneumococcal otitis media was induced in 21 kittens. Thirty-two kitten cochleas were implanted, of which 9 had a fascial graft and 9 a Gelfoam® graft. Nine control cochleas were unimplanted. Labyrinthitis occurred in 44% of unimplanted controls. 50% of implanted ungrafted cochleas, and 6% of implanted grafted cochleas. There was no statistically significant difference between the incidence of labyrinthitis in the implanted cochleas and the unimplanted controls. However there was a statistically significant difference between the ungrafted and grafted cochleas, but not between the two types of graft.
  • Item
    Thumbnail Image
    Acute effects of high-rate stimulation on auditory nerve function in guinea pigs
    Tykocinski, M. ; Shepherd, R. K. ; Clark, Graeme M. ( 1995)
    Cochlear implants have been shown to successfully provide profoundly deaf patients with auditory cues for speech discrimination. Furthermore, a number of safety studies using the Melbourne/Cochlear electrode array indicated that chronic electrical stimulation using charge-balanced biphasic current pulses and stimulus rates between 100 and 500 pulses per second (pps) do not result in additional spiral ganglion loss or general cochlear pathology.1-3 However, safe maximum levels for stimulus parameters (stimulus rate, charge per phase, charge density) have not yet been adequately defined.
  • Item
    Thumbnail Image
    Electrical stimulation of residual hearing in the implanted cochlea
    Clark, Graeme M. ; McAnally, K. I. ; Black, R. C. ; Shepherd, R. K. ( 1995)
    The average profoundly deaf person using a cochlear implant can now understand more speech than some severely to profoundly deaf people who use a hearing aid. For this reason there will be an increasing need to consider implanting people with residual hearing. In many of these people there could be significant hearing in the operated ear, as a majority of severely to profoundly deaf people are likely to have a symmetrical hearing loss. When three frequency average hearing thresholds were measured on 219 pensioners from the Australian National Acoustic Laboratories (H. Dillon, unpublished findings), 64% had less than a 10-dB difference between thresholds in each ear.
  • Item
    Thumbnail Image
    Cochlear implantation: osteoneogenesis, electrode-tissue impedance, and residual hearing
    Clark, Graeme M. ; Shute, S. A. ; Shepherd, R. K. ; Carter, T. D. ( 1995)
    This study was undertaken to find out how new bone is produced in the implanted cochlea, and the effects of fibrous tissue and new bone growth on electrode-tissue impedance. This knowledge is essential, as bone and fibrous tissue in the cochlea could account for variations in patients' speech perception performance. The study was also carried out to examine the effects of implantation on residual hearing. This information is also important, as cochlear implant speech perception results in profoundly deaf people are now better on average than severely or profoundly deaf people obtain with a hearing aid. Consequently, more people will need to be considered for cochlear implantation in ears with some residual hearing. In this case we need to know to what extent residual hearing is affected by implantation. (From Introduction)
  • Item
    Thumbnail Image
    Evaluation of a new Spectral Peak coding strategy for the Nucleus 22 channel cochlear implant system
    Skinner, Margaret W. ; Clark, Graeme M. ; Whitford, Lesley A. ; Seligman, Peter M. ; Staller, Steven J. ; Shipp, David B. ; Shallop, Jon K. ; Everingham, Colleen ; Menapace, Christine M. ; Arndt, Patti L. ; Antogenelli, Trisha ; Brimacombe, Judith A. ; Pijl, Sipke ; Daniels, Paulette ; George, Catherine R. ; McDermott, Hugh J. ; Beiter, Anne L. ( 1994)
    Sixty-three postlinguistically deaf adults from four English-speaking countries participated in a 17-week field study of performance with a new speech coding strategy, Spectral Peak (SPEAK), and the most widely used strategy, Multipeak (MPEAK), both of which are implemented on wearable speech processors of the Nucleus 22 Channel Cochlear Implant System; MPEAK is a feature-extraction strategy, whereas SPEAK is a filterbank strategy. Subjects' performance was evaluated with an experimental design in which use of each strategy was reversed and replicated (ABAB). Average scores for speech tests presented sound-only at 70 dB SPL were higher with the SPEAK strategy than with the MPEAK strategy. For tests in quiet, mean scores for medial vowels were 74.8 percent versus 70.1 percent; for medial consonants, 68.6 percent versus 56.6 percent; for monosyllabic words, 33.8 percent versus 24.6 percent; and for sentences, 77.5 percent versus 67.4 percent. For tests in noise, mean scores for Four-Choice Spondees at +10 and +5 dB signal-to-noise ratio (S/N) were 88.5 percent versus 73.6 percent and 80.1 percent versus 62.3 percent, respectively; and for sentences at +15 dB, +10, and +5 dB S/N, 66.5 percent versus 43.4 percent, 61.5 percent versus 37.1 percent, and 60.4 percent versus 31.7 percent, respectively. Subjects showed marked improvement in recognition of sentences in noise with the new SPEAK filterbank strategy. These results agree closely with subjects' responses to a questionnaire on which approximately 80 percent reported they heard best with the SPEAK strategy for everyday listening situations.
  • Item
    Thumbnail Image
    Partial hearing loss in the macaque following the co-administration of kanamycin and ethacrynic acid
    Shepherd, R. K. ; Xu, S. A. ; Clark, Graeme M. ( 1994)
    Co-administration of kanamycin (KA) with the loop diuretic ethacrynic acid (EA) rapidly produces a profound hearing loss in the cat while maintaining normal renal function [Xu et al., Hear. Res. 70, 205-215 (1993)]. In the present paper we have applied this deafening procedure to the old world monkey Macaca fascicularis (macaque). Following the co-administration of KA and EA, the hearing loss in the macaque developed far slower than we observed in the cat. Moreover, unlike the cat, there was evidence of a partial recovery in the animal’s hearing, resulting in a bilaterally symmetrical high frequency hearing loss. The extent of this hearing loss was dependent on the dose of the EA administered. Finally, the most unexpected result of the present study was the degree of acute nephrotoxicity experienced by these animals following the drug administration. The sensitivity of this species to renal failure restricted the dose of EA that could be safely administered. In conclusion, the co-administration of KA and EA cannot reliably produce a profound hearing loss in the macaque. While it can produce a dose dependent high frequency hearing loss the animal will also experience acute renal failure that requires careful management.
  • Item
    Thumbnail Image
    Cochlear implantation in children: labyrinthitis following pneumococcal otitis media in unimplanted and implanted cat cochleas
    Dahm, Markus C. ; Clark, Graeme M. ; Franz, Burkhard K-H. ; Shepherd, Robert K. ; Burton, Martin J. ; ROBINS-BROWNE, ROY ( 1994)
    Pneumococcal otitis media is frequent in young children and could lead to labyrinthitis post-implantation. To assess the risk and methods of minimizing it by a graft to the round window around the electrode entry point, we have used a cat animal model of pneumococcal otitis media. Twenty-one kittens were used in the study. Thirty-two cochleas were implanted when the kittens were 2 months of age. Fourteen cochleas were implanted without using a graft (12 were available for study); 9 had a fascial graft, and 9 a Gelfoam® graft (7 were available for study). The implanted kittens had their bullae inoculated with Streptococcus pneumoniae 2 months after implantation and were sacrificed 1 week later. There were also 9 unimplanted control ears which were inoculated when the animals were 4 months of age. Labyrinthitis occurred in 44% of unimplanted control, 50% of implanted ungrafted, and 6% of implanted grafted (fascia and Gelfoam®) cochleas. There was no statistically significant difference between the unimplanted control and the implanted cochleas (p < 0.05). There was, however, a difference between the implanted-ungrafted and implanted grafted cochleas, but not between the use of fascia and Gelfoam® to graft the round window entry point. As a result, the data indicates that cochlear implantation does not increase the risk of labyrinthitis following pneumococcal otitis media, but it is desirable to use fascia as a graft to the round window around the electrode entry point.