Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 3 of 3
  • Item
    Thumbnail Image
    A multiple-channel cochlear implant: an evaluation using open-set CID sentences
    Clark, Graeme M. ; Tong, Yit Chow ; Martin, Lois F. A. ( 1981)
    A multiple-channel cochlear implant and speech processor have been used in two postlingually deaf adult patients with a total hearing loss, to enable them to perceive varying degrees of running speech. The results have been confirmed with open-set CID everyday sentence tests. Using the implant alone, the patients obtained 8% and 14% scores with pre-recorded material, and 34% and 36% scores for "live" presentations. This was equivalent to the perception of 35% of connected discourse. When the implant was used in conjunction with lipreading, improvements of 188% and 386% were obtained over lipreading alone, and the scores were 68% and 98% which were equivalent to the perception of 60% and 95% of connected discourse.
  • Item
    Thumbnail Image
    A multiple-channel cochlear implant and wearable speech-processor: an audiological evaluation
    Tong, Y. C. ; Clark, Graeme M. ; Dowell, R. C. ; Martin, L. F. ; Seligman, P. M. ; Patrick, J. F. ( 1981)
    Standard audiological tests were administered to a totally deft multiple-channel cochlear implant patient with a wearable speech-processor in a monitored sound field under the following conditions: a wearable unit activated alone (WA), lipreading with the wearable unit off (LA), and wearable unit activated in combination with lipreading (WL). Thresholds obtained for narrow-band noise signals indicated that the wearable unit allowed the patient to detect a variety of sounds at different frequencies. The results obtained in closed-set word tests and open-set word and sentence tests showed significant improvements in word and sentence scores from LA to WL. In the open-se (C.I.D) sentence tests, the patient scored 22% for LA and 76% for WL. The WL score of 76% correlates with a satisfactory performance in understanding connected speech. The patient also scored 30% correct in a test involving the recognition of environmental sounds.
  • Item
    Thumbnail Image
    Electrical stimulation of the human cochlea: psychophysical and speech studies
    Clark, Graeme M. (Plenum Publishing Corporation, 1981)
    This report describes psychophysical and speech studies conducted on two of our post-lingually deaf patients implanted with the nature of the hearing sensations produced by the individual electrodes, and to investigate the feasibility of the transmission of speech information to higher centres by means of cadences of stimulation using on electrode at a time. Two totally deaf patients (MC1 and MC2) participated in these studies.