  • Item
    Thumbnail Image
    Evaluation of a new Spectral Peak coding strategy for the Nucleus 22 channel cochlear implant system
    Skinner, Margaret W. ; Clark, Graeme M. ; Whitford, Lesley A. ; Seligman, Peter M. ; Staller, Steven J. ; Shipp, David B. ; Shallop, Jon K. ; Everingham, Colleen ; Menapace, Christine M. ; Arndt, Patti L. ; Antogenelli, Trisha ; Brimacombe, Judith A. ; Pijl, Sipke ; Daniels, Paulette ; George, Catherine R. ; McDermott, Hugh J. ; Beiter, Anne L. ( 1994)
    Sixty-three postlinguistically deaf adults from four English-speaking countries participated in a 17-week field study of performance with a new speech coding strategy, Spectral Peak (SPEAK), and the most widely used strategy, Multipeak (MPEAK), both of which are implemented on wearable speech processors of the Nucleus 22 Channel Cochlear Implant System; MPEAK is a feature-extraction strategy, whereas SPEAK is a filterbank strategy. Subjects' performance was evaluated with an experimental design in which use of each strategy was reversed and replicated (ABAB). Average scores for speech tests presented sound-only at 70 dB SPL were higher with the SPEAK strategy than with the MPEAK strategy. For tests in quiet, mean scores for medial vowels were 74.8 percent versus 70.1 percent; for medial consonants, 68.6 percent versus 56.6 percent; for monosyllabic words, 33.8 percent versus 24.6 percent; and for sentences, 77.5 percent versus 67.4 percent. For tests in noise, mean scores for Four-Choice Spondees at +10 and +5 dB signal-to-noise ratio (S/N) were 88.5 percent versus 73.6 percent and 80.1 percent versus 62.3 percent, respectively; and for sentences at +15 dB, +10, and +5 dB S/N, 66.5 percent versus 43.4 percent, 61.5 percent versus 37.1 percent, and 60.4 percent versus 31.7 percent, respectively. Subjects showed marked improvement in recognition of sentences in noise with the new SPEAK filterbank strategy. These results agree closely with subjects' responses to a questionnaire on which approximately 80 percent reported they heard best with the SPEAK strategy for everyday listening situations.
  • Item
    Thumbnail Image
    Pitch perception for different modes of stimulation using the Cochlear multiple-electrode prosthesis
    Busby, P. A. ; Whitford, L. A. ; Blamey, P. J. ; Richardson, L. M. ; Clark, Graeme M. ( 1994)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Silastic with polyacrylic acid filler: swelling properties, biocompatibilty and potential use in cochlear implants
    Seldon, H. L. ; Dahm, M. C. ; Clark, Graeme M. ; Crowe, S. ( 1994)
    We present a new hygroscopic implant material which consists of high-molecular-weight polyacrylic acid (PAA) as a filler in a Silastic ® matrix. The mixture swells upon immersion in bodily fluids; the degree of swelling depends on the ratio of PAA to Silastic and allows the design of implants that will achieve their final shape and size only after the implantation procedure. In vivo and in vitro biocompatibility tests reveal no adverse cellular or tissue responses. In cochlear implant development the material has been experimentally incorporated into intracochlear electrode arrays which curl after insertion, and in bacteriostatic devices for electrode fixation.
  • Item
    Thumbnail Image
    Cochlear implantation in young children: histological studies on head growth, leadwire design, and electrode fixation in the monkey model
    Burton, M. J. ; Shepherd, R. K. ; Xu, S. A. ; Xu, J. ; Franz, B. K-H. G. ; Clark, Graeme M. ( 1994)
    For safe cochlear implantation in children under 2 years of age, the implant assembly must not adversely affect adjacent tissues or compromise head growth. Furthermore, growth changes and tissue responses should not impair the function of the device. Dummy receiver-stimulators, interconnect plugs, and leadwire-lengthening systems were implanted for periods of 36 months in the young monkey to effectively model the implantation of the young child. The results show that implanting a receiver-stimulator package has no adverse effects on skull growth or the underlying central nervous system. The system for fixing the electrode at the fossa incudis proved effective. There was marked osteoneogenesis in the mastoid cavity, resulting in the fixation of the leadwire outside the cochlea. This study provides evidence for the safety of cochlear implantation in young subjects.
  • Item
    Thumbnail Image
    Psychophysical and speech perception studies: a case report on a binaural cochlear implant subject
    van Hoesel, R. J. M. ; Tong, Y. C. ; Hollow, R. D. ; Clark, Graeme M. ( 1993)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Stimulation of residual hearing in the cat by pulsatile electrical stimulation of the cochlea
    McAnally, Ken I. ; Clark, Graeme M. ( 1994)
    Electrical stimulation of the cochlea may excite residual inner hair cells, either by direct electrical stimulation or through a mechanical event. Hair cell mediated responses of the auditory nerve to electrical stimulation were estimated from forward masking of the compound action potential evoked by an acoustic probe. Masking by a fixed electrical masker peaked for probes equal in frequency to the pulse repetition rate and its second harmonic, suggesting a spatially tuned profile of excitation within the cochlea. Furthermore, the tuning curves for masking of a fixed acoustic probe peaked for masker pulse rates close to the frequency of the probe. A secondary peak of masking was commonly seen for electrical stimulation at one half of the probe frequency, suggesting masking of the probe by the second harmonic of the electrical stimulus. These results suggest that pulsatile stimulation at the base of the cochlea generates a spectrally rich mechanical disturbance in which each component propagates to its place of resonance in the cochlea.
  • Item
    Thumbnail Image
    Comparison of half-band and full-band electrodes for intracochlear electrical stimulation
    Xu, Shi-Ang ; McAnally, Ken I. ; Xu, Jin. ; Clark, Graeme M. ( 1993)
    It was hypothesized that intracochlear stimulating electrodes oriented toward the modiolus would require a lower stimulus current to elicit a threshold neural response than longitudinal band electrodes. Electrically evoked auditory brain stem responses (EABRs) and electrode impedances were recorded with full-band and oriented half-band scala tympani electrodes in anesthetized, deafened cats. To elicit a threshold EABR, the stimulus current required for stimulation through half-band electrodes oriented toward the modiolus was not significantly different from the current required for stimulation through full-band electrodes. The impedances of full-band electrodes were significantly lower than those of half-band electrodes. Considering the significantly higher impedance and current density of half band electrodes in comparison to full-band electrodes, as well as the critical orientation of half-band electrodes during implantation, we believe that full-band electrodes have advantages over half-band electrodes for scala tympani implantation.
  • Item
    Thumbnail Image
    Cochlear pathology following chronic electrical stimulation of the auditory nerve. I: Normal hearing kittens
    Ni, Daofeng ; Shepherd, Robert K. ; Seldon, Lee ; Xu, Shi-Ang ; Clark, Graeme M. ; Millard, Rodney E. ( 1992)
    The present study examines the histopathological effects of long-term intracochlear electrical stimulation in young normal hearing animals. Eight-week old kittens were implanted with scala tympani electrode arrays and stimulated for periods of up to 1500 h using charge balanced biphasic current pulses at charge densities in the range 21-52 µC cm^-2 geom. per phase. Both click and electrically evoked auditory brainstem responses were periodically recorded to monitor the status of the hair cell and spiral ganglion cell populations. In addition, the impedance of the stimulating electrodes was measured daily to monitor their electrical characteristics during chronic implantation. Histopathological examination of the cochleas showed no evidence of stimulus induced damage to cochlear structures when compared with implanted, unstimulated control cochleas. Indeed, there was no statistically significant difference in the ganglion cell density adjacent to the stimulating electrodes when compared with a similar population in implanted control cochleas. In addition, hair cell loss, which was restricted to regions adjacent to the electrode array, was not influenced by the degree of electrical stimulation. These histopathological findings were consistent with the evoked potential recordings. Finally, electrode impedance data correlated well with the degree of tissue growth observed within the scala tympani. The present findings indicate that the young mammalian cochlea is no more susceptible to cochlear pathology following chronic implantation and electrical stimulation than is the adult.
  • Item
    Thumbnail Image
    A physiological investigation of chronic electrical stimulation with scala tympani electrodes in kittens
    Ni, Daofeng ; Shepherd, Robert K. ; Clark, Graeme M. ( 1992)
    A physiological investigation of cochlear electrical stimulation was undertaken in six two-month-old kittens. The scala tympani electrodes were implanted and electrically stimulated using biphasic balanced electrical pulses' for periods of 1000-1500h in four ears. Four ears received implants for same period but without electrical stimulation. The other two ears served as normal control. The results indicated: 1) Chronic electrical stimulation of the cochlea within electrochemically safe limits did not influence the hearing of kittens and the normal delivery of impulses evoked by acoustic and electrical signals on the auditory brainstem pathway. 2) The wave shapes of EABRs were similar to those of ABRs. The aptitudes of EABRs showed a significant increase following chronic electrical stimulation, resulting in a leftward shift in the input/ output function. The absolute latencies and interwave latencies of waves II-III , III -IV and II -IV were significantly shorter than those of ABRs. These results imply that there was no adverse effect of chronic electrical stimulation on the maturing auditory systems of kittens using these electrical parameters and the mechanism of electrical hearing should be further studied.
  • Item
    Thumbnail Image
    The excitability of units in the central nucleus of the inferior colliculus to monaural electrical stimulation
    Lithgow, Brian J. ; Clark, Graeme M. ; Tong, Yit C. ( 1992)
    Single unit responses to electric stimuli can be markedly different to those obtained with comparable acoustic stimuli. For the development of future cochlear implant coding strategies a detailed understanding of the effects of electrical stimulation is required. This study investigated the comparative number of single units exhibiting excitatory responses in the central nucleus of the inferior colliculus to monaural electric versus acoustic stimuli.