Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 19
  • Item
    Thumbnail Image
    Preliminary results on spectral shape perception and discrimination of musical sounds by normal hearing subjects and cochlear implantees
    Stainsby, Thomas H. ; McDermott, Hugh J. ; McKay, Colette M. ; Clark, Graeme M. ( 1997)
    This paper presents an overview of an ongoing research project investigating the perception of musical timbre by people with normal hearing, impaired hearing, and cochlear implants. The investigation of musical timbre has been limited to the perception of steady-state frequency spectra from 10 different sources, including sampled acoustic instruments, sung vowels, and synthetic waveforms. Subjects were tested in three different tasks: I) the discrimination of spectra when presented in all possible pairs; 2) the measurement of the internally-perceived frequency spectra using a forward-masking paradigm; and 3) the identification of the spectra by name with the restricted set of sound sources from which they were sampled. Preliminary results from the normally hearing subjects show the spectra to be 99.8% distinguishable, and that significant detail is evident in the internal spectral envelopes from different sounds. There was around 50%-correct identification of stimuli by name with the original sound sources from which they were sampled. The experimental work with hearing impaired and cochlear implant subjects has commenced.
  • Item
    Thumbnail Image
    Peri-modiolar electrode arrays: a comparison of electrode position n the human temporal bone
    Shepherd, R. K. ; Treaba, C. G. ; Cohen, L. ; Pyman, B. ; Huigen, J. ; Xu, J. ; Clark, Graeme M. (Monduzzi Editore, 1997)
    This paper describes a radiologic evaluation of three types of peri-modiolar arrays, comparing their trajectory within the scala tympani with a standard Mini-22 electrode. All peri-modiolar arrays were found to lie closer to the modiolus for much of their insertion length compared with the standard array. While one design showed evidence for the potential of increased insertion trauma, two designs produced satisfactory results. Although further electrode development, temporal bone and histopathologic studies arE required, it would appear that the benefits of peri-modiolar electrode arrays will be realised clinically.
  • Item
    Thumbnail Image
    Evoked potential assessment of children with severe/profound hearing loss: a comparison of steady-state evoked potential (SSEP) and behavioural hearing threshold levels in subjects with absent click evoked auditory brainstem responses (ABR)
    Rance, G. ; Dowell, Richard, C. ; Rickards, F. W. ; Clark, Graeme M. (Monduzzi Editore, 1997)
    Steady-state evoked potential testing offers a means of obtaining accurate, frequency specific estimates of hearing threshold in subjects with even severe to total hearing losses. As such, the technique can play an important role in the preoperative evaluation of young cochlear implant candidates.
  • Item
    Thumbnail Image
    Siting the receiver-stimulator of the CI-24M model of the Cochlear Limited multiple-channel cochlear implant and fixation of its electrode array
    PYMAN, BRIAN ; Clark, Graeme M. (Monduzzi Editore, 1997)
    The correct siting of the cochlear implant receiver-stimulator package is important. The package should not obtrude significantly above the surface of bone, and should be so that blows to the head do not in damage to the package, skull or brain. The cochlear implant electrode array must be fixed at a site close to the cochlea, so that the electrode will not slide out, or be subject to differential movement with growth changes. Fixation, with Dacron® mesh, platinum-iridium ties, or clips, has been in the region of the posterior root of the zygoma and the floor of the antrum. Our research studies demonstrate that a specially-designed collar around the array can be placed through the cochleostomy and provide the necessary locking to prevent retraction of the array. It has a ceramic surround to encourage union with neighbouring bone, and stress relief to reduce wire fracture at the point where the array leaves the cochlea.
  • Item
    Thumbnail Image
    Development of silicon microelectrodes for cochlear implant technology
    Parker, Joanna R. ; Harrison, H. Barry ; Clark, Graeme M. ; Patrick, Jim ; Reinhold, Olaf (Piscataway, 1997)
    Silicon fabrication technology is being explored as a possible solution to the manufacturing of advanced cochlear implant electrode arrays. Silicon probes have been produced with thickness of 5?m and coated in Parylene� polymer to provide strength. To enable handling they are given a backing of silicone rubber before surgical use. This paper presents some techniques used to produce such silicon microelectrodes.
  • Item
    Thumbnail Image
    The effect of pulsatile intracochlear electrical stimulation on intracellularly recorded cochlear nucleus neurons
    Paolini, Antonio, G. ; Clark, Graeme M. (Monduzzi Editore, 1997)
    The anterior division of the ventral cochlear nucleus (AVCN) is the first relay station of the auditory pathway. We examined responses of neurons in the A VCN to intracochlear electrical stimulation using in vivo intracellular recordings. Twin pulse stimulation results indicated that these neurones evoke action potentials which are able to follow pulsatile stimulation at high rates. This ability to respond to each pulse along the stimulus train diminished when stimulus duration was increased to 50 ms. At rates 400 Hz and below in all neurones tested a deterministic response was seen to this longer duration pulsatile stimulation. With increasing rate of stimulation the response become more stochastic with apparent loss of encoding ability. These results have in1pIications in the clinical application of cochlear implants operating at high stimulus rates.
  • Item
    Thumbnail Image
    The relationship between aetiology of hearing loss and outcome following cochlear implantation in a paediatric population
    O'Sullivan, P. G. ; Ellul, S. M. ; Dowell, B. C. ; Clark, Graeme M. (Monduzzi Editore, 1997)
    Eighty-eight children who underwent cochlear implantation at the University of Melbourne Cochlear Implant Clinic are reviewed. The aetiology of the hearing loss is classified and is compared to their best level of speech perception performance. The group whose hearing loss was not congenital in origin performed better than those who were congenital in origin. Of those whose hearing loss was congenital in nature those with rubella appeared to perform best.
  • Item
    Thumbnail Image
    Temporal coding in auditory neurons to electrical stimulation
    Hocking, J. ; Brown, M. ; Clark, Graeme M. (Monduzzi Editore, 1997)
    Different electrically evoked response properties are elicited by similar acoustically differentiated AVCN units. Discharge entrainment and synchrony of some AVCN units is maintained throughout the electrical stimulus duration at all rates, similar to that described for auditory nerve fibres. Other units exhibit a decline in discharge entrainment over the duration of the electrical stimulus with increasing rate. Within this group of units, some exhibit a highly synchronous response while others show a decline in the response synchrony with increasing stimulus rate.
  • Item
    Thumbnail Image
    Rehabilitation strategies for adult cochlear implant users
    Dowell, R. C. ; Blamey, P. J. ; Clark, Graeme M. (Monduzzi Editore, 1997)
    This paper summarizes open-set speech perception results using audition alone for a large group of adult Nucleus cochlear implant users in Melbourne. The results show wide variation in performance but significant improvement over the years from 1982 to 1995. Analysis of these results shows that speech processor developments have made the major contribution to this improvement over this time. Recent results for patients using the SPECTRA-SPEAK processor show !hat most subjects obtain good speech perception within six months of implantation and the need for intensive auditory training is minimal for many of these patients. Postoperative care should encourage consistent device use by providing opportunities for success and providing long term technical support for implant users. In some cases, including elderly patients, those with long term profound deafness, and those with special needs, there will still be a need for additional rehabilitation and auditory training support.
  • Item
    Thumbnail Image
    Factors affecting outcomes in children with cochlear implants
    Dowell, R. C. ; Blamey, P. J. ; Clark, Graeme M. (Monduzzi Editore, 1997)
    Open-set speech perception tests were completed for a group of 52 children and adolescents who were long-term users of the Nucleus multiple channel cochlear prosthesis. Results showed mean scores for the group of 32.4% for open-set BKE sentences and 48.1% for phonemes in open-set monosyllabic words. Over 80% of the group performed significantly on these tas1cs. Age at implantation was identified as a significant factor affecting speech perception performance with improved scores for children implanted early. This factor was evident in the results at least down to the age of three years. Duration.. of profound hearing loss, progressive hearing loss, educational program and preoperative residual hearing were also identified as significant factors that may affect speech perception performance.