Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 3 of 3
  • Item
    Thumbnail Image
    Vowel imitation task: results over time for 28 cochlear implant children under the age of eight years
    Dettman, S. J. ; Barker, E. J. ; Dowell, R. C. ; Dawson, P. W. ; Blamey, P. J. ; Clark, Graeme M. ( 1995)
    With increasing numbers of implanted children under the age of 4 years, numerous researchers have reminded us of the need for valid, sensitive, and reliable tests of developing speech perception.1,2 In addition to studies of the efficacy of implanted prostheses, there is a need to investigate the many variables that influence children's communicative performance, such as changes in speech-coding strategy, updated speech-processing systems, the effects of various training regimens, and the selection of educational and communication modes.
  • Item
    Thumbnail Image
    Speech perception, production and language results in a group of children using the 22-electrode cochlear implant
    Blamey, P. J. ; Dawson, P. W. ; Dettman, S. J. ; Rowland, L. C. ; Brown, A. M. ; Busby, P. A. ; Dowell, R. C. ; Rickards, F. W. ; Clark, Graeme M. ( 1992)
    Five children out of a group of nine (aged 5.5 to 19.9 years) implanted with the 22-electrode cochlear implant (Cochlear Ply. Ltd.) have achieved substantial scores on open-set speech tests using hearing without lipreading. Phoneme scores for monosyllabic words ranged from 40% to 72%. Word scores in sentences ranged from 26% to 74%. Four of these five children were implanted during preadolescence. The fifth child, who had a progressive loss and was implanted during adolescence after a short period of very profound deafness, scored highest on all speech perception tests. The remaining four children who did not demonstrate open-set recognition were implanted during adolescence after a long duration of profound deafness. Post-operative performance on closed-set speech perception tests was better than pre-operative performance for all children. Improvements in speech and language assessments were also noted. These improvements tended to be greater for the younger children. The results are discussed with reference to variables which may contribute to successful implant use: such as age at onset, duration of profound hearing loss, age at implantation, aetiology, educational program, and the type of training provided.
  • Item
    Thumbnail Image
    Electrode position, repetition rate, and speech perception by early-and-late-deafened cochlear implant patients
    Busby, P. A. ; Tong, Y. C. ; Clark, Graeme M. ( 1993)
    Psychophysical and speech perception studies were conducted on eight patients using the 22electrode cochlear implant manufactured by Cochlear Pty. Ltd. Four early-deafened patients became deafened at 1-3 years of age and were implanted at 5-14 years of age. Four late-deafened (postlingual adult) patients became deafened at 38-47 years of age and were implanted at 42-68 years of age. Psychophysical studies measured the discrimination of trajectories with time-varying electrode positions and repetition rates. Speech perception studies measured performance using two speech coding strategies: a multi-electrode strategy which coded the first and second formant frequencies, the amplitudes of the two formants, and the fundamental frequency; and a single-electrode strategy which coded the amplitudes of the first and second formants, and the fundamental frequency. In general, the four late-deafened patients and one early-deafened patient were more successful than the other three early-deafened patients in the discrimination of electrode position trajectories and in speech perception using the multi-electrode strategy. Three of the four late-deafened patients were more successful than the early-deafened patients in the discrimination of repetition rate trajectories. Speech perception performance in the single-electrode strategy was closely related to performance in repetition rate discrimination. The improvement in speech perception performance from the single-electrode to multi-electrode strategy was consistent with successful performance in electrode discrimination.