  • Item
    Thumbnail Image
    Electrode discrimination by early-deafened subjects using the Cochlear Limited multiple electrode cochlear implant
    Busby, P. A. ; Clark, Graeme M. ( 2000)
    Objective: The aims of this study were to determine whether electrode discrimination by early-deafened subjects using the Cochlear Limited prosthesis varied at different locations on the electrode array, was influenced by the effects of auditory deprivation and experience with electric stimulation, and was related to speech perception. Design: Difference limens for electrode discrimination were measured in 16 early-deafened subjects at three positions on the array: electrodes 18 (apical), 14 (mid), and 8 (basal). Electrodes were stimulated using random variations in current level to minimize the influence of loudness cues. Assessed were correlations between the difference limens, subject variables related to auditory deprivation (age at onset of deafness, duration of deafness, and age at implantation) and auditory experience (duration of implant use and the total time period of auditory experience), and speech perception scores from two closed-set and two open-set tests. Results: The average difference limens across the three positions were less than two electrodes for 75%, of subjects, with average limens between 2 and 6.5 electrodes for the remaining 25% of subjects. Significant differences across the three positions were found for 69% of subjects. The average limens and those at the basal position positively correlated with variables related to auditory deprivation, with larger limens for subjects implanted at a later age and with a longer duration of deafness. The average limens and those at the apical position negatively correlated with closed-set speech perception scores, with lower scores for subjects with larger limens, but not with open-set scores. Speech scores also negatively correlated with variables related to auditory deprivation. Conclusions: These findings showed that early-deafened subjects were generally successful in electrode discrimination although performance varied across the array for over half the subjects. Discrimination performance was influenced by the effects of auditory deprivation, and both electrode discrimination and variables related to auditory deprivation influenced closed-set speech perception.
  • Item
    Thumbnail Image
    Psychophysics of a prototype peri-modiolar cochlear implant electrode array
    Cohen, LT ; Saunders, E ; Clark, GM (ELSEVIER SCIENCE BV, 2001-05)
    Psychophysical measurements were performed in three hearing-impaired adult subjects implanted with a CI22 cochlear prosthesis (Cochlear Ltd.) fitted with a developmental peri-modiolar electrode array. The array was manufactured with a curvature approximating that of the inner wall of the scala tympani but, after straightening and insertion, lay on average about half way between the inner and outer walls of the scala. All subjects were tested with bipolar stimulation; two were also tested with monopolar, employing the most basal electrode as the return. Maximum comfortable level and threshold reduced with decreasing distance of electrode from the modiolus, whereas dynamic range increased. The linearity of the loudness growth function did not vary significantly with electrode position but the function was more non-linear for lower maximum comfortable levels. Current level discrimination, normalized with respect to dynamic range, improved with decreasing distance of electrode from the modiolus in two subjects. Pitch varied regularly with insertion depth of the stimulated electrode for bipolar stimulation in two subjects and also for monopolar stimulation in one subject. Electrode discrimination was enhanced by closeness to the modiolus. Whereas the forward masking patterns for bipolar stimulation of electrodes close to the modiolus had a sharp double-peaked structure, those for monopolar stimulation were flatter and had a single peak.
  • Item
    Thumbnail Image
    Electrode discrimination and speech perception in young children using cochlear implants
    Dawson, P. W. ; McKay, C. M. ; Busby, P. A. ; Grayden, D. B. ; Clark, Graeme M. ( 2000)
    Objective: The aim was to determine the efficacy of a child-appropriate procedure to assess electrode discrimination ability in young children using cochlear implants and to investigate the relationship of electrode discrimination ability and speech perception performance in children implanted at a young age. Design: An adaptation of the play audiometry procedure was used to assess electrode discrimination in seventeen 4- to 10-yr-old children. The children were required to respond with a game-like motor response when a repeating stimulation on a reference electrode “changed” to a different electrode. They were also assessed on a speech feature discrimination test, a closed-set word recognition test and a nonverbal intelligence task. Results: Sixty-five percent of subjects demonstrated ability to discriminate adjacent electrodes in mid and apical regions of the cochlea, whilst the remaining subjects needed electrode separations of between two and nine electrodes for successful discrimination. In a forward stepwise regression analysis electrode discrimination ability was found to be the strongest factor in accounting for variance in the speech perception scores. Subject variables such as duration of deafness, nonverbal intelligence and implant experience did not significantly account for further variance in the speech perception scores for this group of children. Conclusions: Electrode discrimination ability was the strongest factor in predicting performance on speech perception measures in a group of children using cochlear implants.