Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 17
  • Item
    Thumbnail Image
    The Melbourne Cochlear Implant Clinic program
    Cowan, Robert S. C. ; Clark, Graeme M. (Singular Publishing, 1997)
    The Melbourne Cochlear Implant Clinic program involves a multidisciplinary clinical team, collaborating with those engaged in more fundamental research, and with the biomedical company Cochlear Limited. This chapter reflects the contributions of many professionals to managing children with cochlear implants.
  • Item
    Thumbnail Image
    Multichannel auditory brainstem implants: an Australian case study [Abstract]
    Hollow, Rod ; COWAN, ROBERT ; BRIGGS, ROBERT ; KAYE, ANDREW ; DOWELL, RICHARD ; Shaw, Stephanie ; Clarke, Graeme M. ( 1996)
    The multichannel Auditory Brainstem Implant (ABI) is an implantable device designed to restore a level of auditory perception in patients with bilateral acoustic neuromas, where the removal of the tumours is expected to result in a total loss of hearing. As with the cochlear implant, the ABI utilises an externally worn speech processor and headset, together with a surgically-placed receiver-stimulator and electrode array. The electrode array, developed through the collaboration of the House Ear Institute in the United States and Cochlear Corporation, consists of eight electrodes on a carrier, which is placed on the surface of the brainstem in the area of the cochlear nucleus.
  • Item
    Thumbnail Image
    A training program for use with multichannel speech perception/production tactile devices [Abstract]
    GALVIN, KARYN ; COWAN, ROBERT ; Mavrias, Gina ; Moore, Alessandra ; SARANT, JULIA ; Clark, Graeme M. ( 1996)
    Over the past ten years, there have been remarkable improvements in both conventional hearing aid technology and in the use of multichannel cochlear prostheses. These developments have resulted in improved speech perception for severely and profoundly hearing impaired adults and children. However, a small number of adults and children remain unable to benefit from either of these prosthetic approaches. This may occur as a result of medical/surgical issues, which render implantation unfeasible, or from a decision by the patient or parents that the device is inappropriate for the individual person. In these cases, use of a supplemental speech perception device employing the intact tactile modality has been advocated. A number of single and multichannel devices have been developed, both commercially and in the laboratory. One of these, the Tickle Talker, a multichannel electrotactile speech processor, has been developed and thoroughly evaluated with both adults and children at the University of Melbourne. Benefits to speech perception have been noted on both closed-set phonemic discrimination tests, and on open-set word and sentence scores, where the device was used to supplement lipreading and/or aided residual hearing. Benefits to articulation have also been noted. Recently, improved speech processing and the design of a new electrode handset have been implemented. While these factors are important to device acceptance, the critical factor in improving speech perception and production appears to be the training program which is employed with the device. The program must be based on the information available through the device, but organised to emphasize the integration of tactually-encoded speech information into open-set understanding of words and sentences if communication is to be improved. The important elements of the program will be discussed. At present, no tactile device is able to provide sufficient information for open-set speech understanding using only the tactile input. While this may be an ultimate goal, significant periods of training may be required to achieve this outcome.
  • Item
    Thumbnail Image
    A clinical report on speech production of cochlear implant users
    Dawson, P. W. ; Blamey, P. J. ; Dettman, S. J. ; Rowland, L. C. ; Barker, E. J. ; Tobey, E. A. ; Busby, P. A. ; Cowan, R. C. ( 1995)
    Objective: The aim was to assess articulation and speech intelligibility over time in a group of cochlear implant users implanted at 8 yr or over. The hypothesis was that the postoperative speech production performance would be greater than the preoperative performance. Design: A test of intelligibility using sentences and an articulation test measuring non-imitative elicited speech were administered to 11 and 10 subjects, respectively, who were implanted with the 22-electrode cochlear implant. Nine subjects received both tests. Age at implantation ranged from 8 yr to 20 yr and implant use ranged from 1 yr to 4 yr 5 mo. Results: For both the intelligibility and articulation tests roughly half of the subjects showed significant improvements over time and group mean postoperative performance significantly exceeded preoperative performance. Improvements occurred for front, middle, and back consonants; for stops, fricatives, and glides and for voiceless and voiced consonants. Conclusions: Despite being deprived of acoustic speech information for many childhood years, roughly half of the patients assessed showed significant gains in speech intelligibility and articulation postimplantation. The lack of a control group of non-implanted patients means that we cannot separate out the influence of the implant on speech production from other influences such as training and tactile-kinaesthetic feedback.
  • Item
    Thumbnail Image
    Speech perception for children with different levels of residual hearing using the cochlear 22-channel cochlear prosthesis [Abstract[
    Cowan, R. S. C. ; Galvin, K. L. ; Barker, E. J. ; Del Dot, J. ; Sarant, J. Z. ; Dettman, S. ; Hollow, R. ; Herridge, S. ; Rance, G. ; Larratt, M. ; Skok, M. ; Dowell, R. C. ; Pyman, B. ; Gibson, W. P. R. ; Clark, Graeme M. ( 1996)
    Over the past 10 years, since the implantation of the first children with the Nucleus 22-channel cochlear prosthesis in Melbourne, the number of profoundly deaf children using this implant system has rapidly expanded. Longer-term experience with implanted children has led to improvements in paediatric assessment and management. Speech processing strategies have also been improved, resulting in a series of increases in speech perception benefits. Results of comparative studies of Speak and Multipeak speech processing strategies have shown that open-set word and sentence scores for a group of thirteen children evaluated over a two year period showed an advantage with the Speak speech processing strategy. The increases were noted particularly in speech perception in poor signal-to-noise conditions. Analysis has shown that consonant perception was significantly increased, due to an improved place perception. Given current speech perception scores for implanted children, it has been suggested that severely-to-profoundly deaf children currently using hearing aids could in fact benefit more from a cochlear implant. Preliminary investigation of results for children in the Melbourne and Sydney cochlear implant programs has shown that children with higher levels of preoperative residual hearing as a group do score significantly on open-set word and sentence perception tests using the implant alone. In children with lower levels of residual hearing, results were variable across the group.
  • Item
    Thumbnail Image
    A review of the biological, psychophysical, and speech processing principles used to design the tickle talker
    Blamey, P. J. ; Cowan, R. S. C. ; Alcantara, J. I. ; Whitford, L. A. ; Galvin, K. L. ; Sarant, J. Z. ; Clark, Graeme M. ( 1992)
    The Tickle Talker is a wearable electrotactile speech processor, designed to be used by profoundly hearing-impaired children and adults in conjunction with lipreading and residual hearing. The effectiveness of such a device is affected by an interaction between biological, human engineering, psychophysical, and speech processing considerations. The requirements, the design principles, and the performance of the Tickle Talker in each of these areas will be discussed. Electrical stimulation of the nerve bundles lying along the sides of the fingers was chosen to provide safe, comfortable, energy-efficient stimulation of a well-organised and sensitive part of the tactile sensory system. This is achieved at a small cost to the appearance and mobility of one hand when using the Tickle Talker. The biphasic pulse waveform used to stimulate the nerve bundles has been chosen to ensure a biologically safe stimulus. The electrical parameters (pulse duration, pulse rate, and electrode position) that are used to encode speech information are varied within ranges that are matched to the characteristics of the tactile sense. The usable ranges and information-carrying potential of each of these parameters have been assessed in psychophysical experiments. A comparison of these results with similar experimental data for cochlear implant and hearing aid users is instructive in assessing the possible limitations of tactile and auditory speech processors. The results discussed will include the discrimination and identification of stimuli differing in intensity, duration and pulse rate; the identification of different spatial patterns of stimulation, and the detection of gaps in stimuli. In most respects, the tactile results are similar to the corresponding auditory measures. The resolution of temporal differences such as pulse rate discrimination or gap detection are generally not as good as in the auditory case, but may be as good or better than the corresponding results for some profoundly hearing-impaired individuals. The speech processor used in the Tickle Talker is a "feature extraction" device that explicitly estimates the second formant frequency, amplitude envelope, and fundamental frequency of the voice and encodes them in terms of electrode position, pulse width and pulse rate of the electrical stimulation pattern. Consideration of the psychophysical results and the speech information available from these parameters allows optimization of the Tickle Talker's operation and a broad estimation of its potential performance in speech discrimination. The perception of duration and place of articulation (front/back) of vowels, and the manner and voicing of consonants are expected to be improved by the Tickle Talker. Prosodic variations conveyed by pulse rate are expected to be perceived by some users, but not all. High frequency consonants such as: /s/,/z/./?/, and /t?/ are encoded in a particularly salient manner by the Tickle Talker.
  • Item
    Thumbnail Image
    The effect of language knowledge on speech perception: what are we really assessing? [Abstract]
    Sarant, J. Z. ; Blamey, P. J. ; Cowan, R. S. C. ; Clark, Graeme M. ( 1996)
    It is a common finding that many hearing-impaired children have poorer language skills than their normally-hearing peers of the same age. It is also logical to assume that the measurement of open-set speech perception in children with cochlear implants could be affected by limited receptive vocabulary and syntactic knowledge. Therefore, we may be significantly underestimating the speech perception abilities of some hearing-impaired children.
  • Item
    Thumbnail Image
    Results of multichannel cochlear implantation in very young children [Abstract]
    Galvin, K. ; Clark, Graeme M. ; DETTMAN, SHANI ; Dowell, Richard C. ; Barker, E. J. ; Rance, G. ; Hollow, R. ; Cowan, R. ( 1995)
    Most researchers and clinicians working in the cochlear implant field have assumed that profoundly deaf children will have a better prognosis in terms of speech perception, speech production and language development, implanted at as young an age as possible. However, it has been difficult to gather direct evidence for this hypothesis due to the problems in assessing children under the age of five years with formal tests.
  • Item
    Thumbnail Image
    Speech perception benefits for children using the Speak speech processing strategy in quiet and noise [Abstract]
    Whitford, L.A. ; Dowell, R.C. ; Brown, C. ; Gibson, W.P.R. ; Clark, Graeme M. ; Cowan, R. S. C. ; Galvin, K. L. ; Barker, E. J. ; Sarant, J. Z. ; Shaw, S. ; Everingham, C. ( 1995)
    The Speak speech processing strategy, based on the Spectral Maxima Speech Processor (SMSP) developed at the University of Melbourne, has now been implemented in the Spectra 22 speech processor developed by Cochlear Pty Limited, and clinical trials of both patients changing from the previous Multipeak strategy to Speak and patients starting up with Speak have been conducted. Results in adult patients changing to Speak have shown significant improvements in speech perception in quiet and particularly in background noise as compared with Multipeak.
  • Item
    Thumbnail Image
    Speech perception results for children changing from multipeak to SPEAK speech processing strategy [Abstract]
    Sarant, J.Z. ; DelDot, J. ; Dettman, S. ; Hollow, R. ; Skok, M. ; Seligman, P.M. ; Dowell, R.C. ; Gibson, W.P.R. ; Clark, Graeme M. ; Cowan, R. S. C. ; Pyman, B. ; Galvin, K. L. ; Shaw, S. ; Barker, E. J. ; Brown, C. ( 1996)
    In mid-1994, a new speech processing strategy termed SPEAK was introduced for the Nucleus Spectra-22 cochlear prostheses. To compare benefits in implanted children changing to the SPEAK strategy, speech perception in a group of twelve children from Melbourne and Sydney was evaluated. The children were assessed in quiet and in background noise.