Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 10
  • Item
    Thumbnail Image
    A modification of play audiometry to assess speech discrimination ability in severe-profoundly deaf 2- to 4-year-old children
    Dawson, P. W. ; Nott, P. E. ; Clark, Graeme M. ; Cowan, Robert S. C. ( 1998)
    Objective: The aim was to develop an assessment procedure that was independent of language and speech production ability, to test speech feature discrimination severe-profoundly deaf children 2 to 4 yr of age. Design: The procedure being trialled was adapted from existing procedures. The child was required to respond with a game-like motor response to a “change” in a speech stimulus that was being presented repeatedly through a speaker. The change occurred at randomly determined times, and false alarm responses were measured during the waiting periods (while the child waited for the change). Two- to four-yr-old normally hearing children and hearing-impaired children using hearing aids and a group of 4-yr-old hearing-impaired children using cochlear implants were assessed on the task. Results: More than 82% of the 3- and 4-yr-old normally hearing and hearing-impaired children were able to complete the testing for the eight speech sound contrasts within three 20 minute sessions. Fifty percent of the 2-yr-old normally hearing and hearing-impaired children were able to condition and complete the task. All of the normally hearing children who completed the task successfully discriminated all speech sound contrasts. The performance of the hearing-impaired children using hearing aids was influenced by the degree of hearing loss and the type of speech contrast being tested. Similarly, the average performance of the children using cochlear implants was better for easier contrasts such as /ba/bi/ with contrasting vowel formant cues. Conclusions: This procedure has potential for use as a reliable clinical and research tool for assessing the development of auditory discrimination ability in 2- to 4-yr-old severe-profoundly deaf children.
  • Item
    Thumbnail Image
    A comparison of Tactaid II+ and Tactaid 7 use by adults with a profound hearing impairment
    Galvin, Karyn L. ; Mavrias, Gina ; Moore, Alessandra ; Cowan, Robert S. C. ; Blamery, Peter J. ; Clark, Graeme M. ( 1999)
    Objective: To evaluate and compare use of the Tactaid II+ and the Tactaid 7, in terms of speech perception, by adults with a hearing impairment. Design: Eight adults used one device daily for approximately 10 wk and attended seven training sessions. Performance was measured with tests of phonetic contrast perception, closed-set vowel and consonant identification, word and phoneme recognition in monosyllabic word lists, word recognition in sentences and speechtracking rate. A questionnaire was also administered. The protocol was repeated with the alternative device. Results: With each device, the group discriminated most phonetic contrasts at better-than-chance levels and demonstrated somewhat enhanced visual or auditory-visual perception when measured in terms of vowel identification, monosyllabic word recognition and speechtracking rate. An increase in speechtracking rate was also demonstrated for some individuals. Subjects generally reported little subjective improvement in speech perception and production, but were satisfied with the physical attributes of each device. Five of six subjects preferred the Tactaid 7. Conclusions: The Tactaid II+ and the Tactaid 7 provided suprasegmental and segmental information, enabling the group to discriminate phonetic contrasts and improve their perception of some speech materials. No consistent advantage was found for either device, thought most subjects preferred the Tactaid 7. Alternatives likely to provide a greater benefit to communication should be considered before Tactaid fitting.
  • Item
    Thumbnail Image
    The progress of children using the multichannel cochlear implant in Melbourne
    Cowan, R. S. C. ; Dowell, R. C. ; Hollow, R. ; Dettman, S. J. ; Rance, G. ; Barker, E. J. ; Sarant, J. Z. ; Galvin, K. L. ; Webb, R. C. ; Pyman, B. C. ; Cousins, V. C. ; Clark, Graeme M. ( 1995)
    Multi-channel cochlear implantation in children began in Australia in 1985 and there are now close to 4000 profoundly deaf children and adolescents using the Australian implant system around the world. The aim of the implant procedure is to provide adequate hearing for speech and language development through auditory input. This contrasts with the situation for adults with acquired deafness where the cochlear implant aims to restore hearing for someone with well-developed auditory processing and language skills. As with adults, results vary over a wide range for children using the Multi-channel implant. Many factors have been suggested that may contribute to differences in speech perception for implanted children. In an attempt to better understand these factors, the speech perception results for children implanted in Melbourne were reviewed and subjected to statistical analysis. This has indicated that the amount of experience with the implant and the length of sensory deprivation are strongly correlated with perceptual results. This means that younger children are likely to perform better with an implant and that a number of years of experience are required for children to reach their full potential. The results have also indicated that educational placement and management play a crucial role in children reaching their potential. Overall, 60% of the children and adolescents in the study have reached a level of open-set speech understanding using the cochlear implant without lipreading.
  • Item
    Thumbnail Image
    Cochlear implants in children, adolescents, and prelinguistically deafened adults: speech perception
    Dawson, Pam W. ; Blamey, Peter J. ; Rowland, Louise C. ; Dettman, Shani J. ; Clark, Graeme M. ; Busby, Peter A. ; Brown, Alison M. ; Dowell, Richard C. ; Rickards, Field W. ( 1992)
    A group of 10 children, adolescents, and prelinguistically deafened adults were implanted with the 22-electrode cochlear implant (Cochlear Ply Ltd) at the University of Melbourne Cochlear Implant Clinic and have used the prosthesis for periods from 12 to 65 months. Postoperative performance on the majority of closed-set speech perception tests was significantly greater than chance, and significantly better than preoperative performance for all of the patients. Five of the children have achieved substantial scores on open-set speech tests using hearing without lipreading. Phoneme scores in monosyllabic words ranged from 30% to 72%; word scores in sentences ranged from 26% to 74%. Four of these 5 children were implanted during preadolescence (aged 5:5 to 10:2 years) and the fifth, who had a progressive loss, was implanted during adolescence (aged 14:8 years). The duration of profound deafness before implantation varied from 2 to 8 years. Improvements were also noted over postoperative data collection times for the younger children. The remaining 5 patients who did not demonstrate open-set recognition were implanted after a longer duration of profound deafness (aged 13:11to 20:1 years). The results are discussed with reference to variables that may affect implant performance, such as age at onset of loss, duration of profound loss, age at implantation, and duration of implantation. They are compared with results for similar groups of children using hearing aids and cochlear implants.
  • Item
    Thumbnail Image
    Perception of multiple electrode stimulus patterns: implications for design of an electrotactile speech processor
    Cowan, Robert S. C. ; Blamey, Peter J. ; Sarant, Julia Z. ; Galvin, Karyn L. ; Clark, Graeme M. ( 1991)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Perception of sentences, words, and speech features by profoundly hearing-impaired children using a multichannel electrotactile speech processor
    Cowan, Robert S. C. ; Blamey, Peter J. ; Galvin, Karyn L. ; Sarant, Julia Z. ; Alcantara, Joseph I. ; Clark, Graeme M. ( 1990)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Speech feature recognition by profoundly hearing impaired children using a multiple-channel electrotactile speech processor and aided residual hearing
    Alcantara, Joseph I. ; Whitford, Lesley A. ; Blamey, Peter J. ; Cowan, Robert S. C. ; Clark, Graeme M. ( 1990)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Speech feature recognition with an electrotactile speech processor
    Cowan, R. S. C. ; Blamey, P. J. ; Alcantara, J. I. ; Clark, Graeme M. ; Whitford, L. A. ( 1989)
    The performance of eight subjects was assessed on a closed-set tactual test battery to evaluate efficiency of the speech feature encoding strategy currently used in the University of Melbourne multichannel electrotactile speech processor. The test battery included twelve subtests of suprasegmental and segmental speech feature contrasts. Results showed that all subjects scored significantly above chance on suprasegmental features such as syllable number, stress and vowel length. In addition, seven of the eight subjects scored significantly above chance for vowel formant frequency discrimination. Scores for manner of articulation contrasts were more variable, with better performance for the higher frequency, longer duration fricatives and affricates. Scores for voicing contrasts suggested that improvements to the tactual coding of this feature could be achieved. The second study examined the contribution of the tactual input to consonant feature identification for subjects using the electrotactile aid in combination with either a low-pass filtered auditory input or different levels of aided residual hearing and lipreading. Results for four normally-hearing subjects showed increased voicing and manner identification scores with the addition of tactual input. Similar results were found for two hearing-impaired subjects, one using the tactual input in combination with lipreading and one using the tactual input in combination with aided residual hearing.
  • Item
    Thumbnail Image
    Speech perception studies using a multichannel electrotactile speech processor, residual hearing, and lipreading
    Cowan, Robert S. C. ; Alcantara, Joseph I. ; Whitford, Lesley A. ; Blamey, Peter J. ; Clark, Graeme M. ( 1989)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Speech perception using combinations of auditory, visual, and tactile information
    Blamey, Peter J. ; Cowan, Robert S. C. ; Alcantara, Joseph I. ; Whitford, Lesley A. ; Clark, Graeme M. ( 1989)
    Four normally-hearing subjects were trained and tested with all combinations of a highly-degraded auditory input, a visual input via lipreading, and a tactile input using a multichannel electrotactile speech processor. The speech perception of the subjects was assessed with closed sets of vowels, consonants, and multisyllabic words; with open sets of words and sentences, and with speech tracking. When the visual input was added to any combination of other inputs, a significant improvement occurred for every test. Similarly, the auditory input produced a significant improvement for all tests except closed-set vowel recognition. The tactile input produced scores that were significantly greater than chance in isolation, but combined less effectively with the other modalities. The addition of the tactile input did produce significant improvements for vowel recognition in the auditory-tactile condition, for consonant recognition in the auditory-tactile and visual-tactile conditions, and in open-set word recognition in the visual-tactile condition. Information transmission analysis of the features of vowels and consonants indicated that the information from auditory and visual inputs were integrated much more effectively than information from the tactile input. The less effective combination might be due to lack of training with the tactile input, or to more fundamental limitations in the processing of multimodal stimuli.