Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 4 of 4
  • Item
    Thumbnail Image
    Architecture of the Spectra 22 speech processor
    Seligman, P. ; MCDERMOTT, H. ( 1995)
    The Spectra 22 is a logical extension in the development of the speech processing for the Cochlear Mini 22 system. It can implement the new coding strategy (Speak) that has provided significant improvement in patient benefit.
  • Item
    Thumbnail Image
    Coding of voice source information in the Nucleus cochlear implant system
    Jones, P. A. ; McDermott, H. J. ; Seligman, P. M. ; Millar, J. B. ( 1995)
    Two studies are reported in which the effectiveness of explicitly coding voicing and fundamental frequency information for the Nucleus cochlear implant was investigated. ln the first study, the voicing perception of a group of three experienced Multipeak users was evaluated when they were using Multipeak and a modified Multipeak in which the explicit fundamental frequency and voicing cues were eliminated and replaced with a 250-Hz constant rate of stimulation. The results of consonant and monosyllabic word tests showed that there was no significant difference in the subjects' ability to discriminate voicing. In the second study, the ability of a group of five experienced users of the constant rate spectral maxima sound processor (SMSP) strategy to discriminate suprasegmental contrasts was evaluated when they were using the SMSP strategy and a modified SMSP strategy that included a rate-encoded representation of the fundamental frequency on the most apical stimulation channel. The results of intonation, roving stress, and question-statement tests showed that there was no significant difference between the scores recorded with these strategies. Since the temporal voicing cue is not a primary cue to voicing discrimination for Multipeak users, and the provision of an additional rate cue to the SMSP strategy does not improve SMSP users' ability to discriminate suprasegmental contrasts, the results of these studies indicate that in the cases investigated, the coding of voice source information by rate of stimulation does not significantly augment the cues present in the spatially distributed constant rate stimulation pattern.
  • Item
    Thumbnail Image
    Evaluation of a new Spectral Peak coding strategy for the Nucleus 22 channel cochlear implant system
    Skinner, Margaret W. ; Clark, Graeme M. ; Whitford, Lesley A. ; Seligman, Peter M. ; Staller, Steven J. ; Shipp, David B. ; Shallop, Jon K. ; Everingham, Colleen ; Menapace, Christine M. ; Arndt, Patti L. ; Antogenelli, Trisha ; Brimacombe, Judith A. ; Pijl, Sipke ; Daniels, Paulette ; George, Catherine R. ; McDermott, Hugh J. ; Beiter, Anne L. ( 1994)
    Sixty-three postlinguistically deaf adults from four English-speaking countries participated in a 17-week field study of performance with a new speech coding strategy, Spectral Peak (SPEAK), and the most widely used strategy, Multipeak (MPEAK), both of which are implemented on wearable speech processors of the Nucleus 22 Channel Cochlear Implant System; MPEAK is a feature-extraction strategy, whereas SPEAK is a filterbank strategy. Subjects' performance was evaluated with an experimental design in which use of each strategy was reversed and replicated (ABAB). Average scores for speech tests presented sound-only at 70 dB SPL were higher with the SPEAK strategy than with the MPEAK strategy. For tests in quiet, mean scores for medial vowels were 74.8 percent versus 70.1 percent; for medial consonants, 68.6 percent versus 56.6 percent; for monosyllabic words, 33.8 percent versus 24.6 percent; and for sentences, 77.5 percent versus 67.4 percent. For tests in noise, mean scores for Four-Choice Spondees at +10 and +5 dB signal-to-noise ratio (S/N) were 88.5 percent versus 73.6 percent and 80.1 percent versus 62.3 percent, respectively; and for sentences at +15 dB, +10, and +5 dB S/N, 66.5 percent versus 43.4 percent, 61.5 percent versus 37.1 percent, and 60.4 percent versus 31.7 percent, respectively. Subjects showed marked improvement in recognition of sentences in noise with the new SPEAK filterbank strategy. These results agree closely with subjects' responses to a questionnaire on which approximately 80 percent reported they heard best with the SPEAK strategy for everyday listening situations.
  • Item
    Thumbnail Image
    An extension of the Multipeak speech processing strategy for the MSP/MINI 22 cochlear implant system
    Jones, P. A. ; McDermott, H. J. ; Sellgman, P. M. ; Millar, J. B. ( 1992)
    The speech perception of three post-linguistically deaf adults using the Nucleus MSP/Mini System 22 cochlear implant system programmed with a new speech processing strategy, MPEAK+AO. was evaluated. The MPEAK+AO strategy retains all the information of the standard Multipeak speech processing strategy and additionally presents acoustic components below 400Hz to the most-apical electrode. This extra spectral Information may help implantees understand speech, particularly in noise. Since the estimated fundamental frequency is presented as the rate of stimulation at a fixed intracochlear site and is thereby potentially perceived more easily. and the amplitude of the stimulation on the apical electrode, associated with the voice fundamental, Is directly determined from the estimated energy in the relevant spectral region. these coding factors may provide a better representation ot the prosodic information in speech and a more complete auditory feedback signal. The comparison between Multipeak and MPEAK+AO included tests of vowel, consonant and CNC word recognition. Speech materials were presented with both a male and female speaker. Sentence material. presented with background masking noise (four-speaker babble) was also used. The results showed that the new strategy significantly improved the ability of these MSP users to recognise words in open-set sentences in noisy conditions.