    A protocol for the prevention of infection in cochlear implant surgery
    Clark, Graeme M. ; Pyman, Brian C. ; Pavillard, Robin E. (Cambridge University Press, 1980)
    The reduction of infection to an absolute minimum is a very desirable goal in any form of surgery. It is especially important with a cochlear implant operation as infection in the labyrinth can lead to degeneration of the auditory nerve fibres it is hoped to stimulate electrically (Clark et al, 1975). Furthermore, as the implantation of foreign materials increases the risk of infection, as the operation can last 6-7 hours (Altemeier et al., 1976), and as the operators are in very close proximity to the implant site, more stringent measures for the prevention of infection need to be adopted than with other forms of otological surgery. For these reasons a protocol has been developed for preventing infection in our cochlear implant surgery. This is an overall approach to the prevention of infection and involves pre-operative measures, an operating theatre routine, the use of horizontal laminar flow filter units, correct surgical technique and the use of systemic and local antibiotics.
  • Item
    Thumbnail Image
    Preliminary results for the Cochlear Corporation multielectrode intracochlear implant in six prelingually deaf patients
    Clark, Graeme M. ; Busby, Peter A. ; Roberts, Susan A. ; Dowell, Richard C. ; Blamey, Peter J. ; Mecklenburg, Dianne J. ; Webb, Robert L. ; Pyman, Brian C. ; Franz, Burkhard K. ( 1987)
    The preliminary results from this study indicate that some prelingually deaf patients may get worthwhile help from a multiple-electrode cochlear implant that uses a formant-based speech processing strategy. It is encouraging that these improvements can occur in young adults and teenagers. The results for two children are also encouraging. A 10-year-old child obtained significant improvement on some speech perception tests. It was easy to set thresholds and comfortable listening levels on a 5-year-old child, and he is now a regular user of the device. There are, however, considerable variations in performance among the prelingual patients, which may be related to the following factors: whether they have had some hearing after birth, the method of education used, the motivation of the patient, and age at implantation.
  • Item
    Thumbnail Image
    A multiple-electrode intracochlear implant for children
    Clark, Graeme M. ; Blamey, Peter J. ; Busby, Peter A. ; Dowell, Richard C. ; Franz, Burkhard K-H. ; Musgrave, Gaye Nicholls ; Nienhuys, Terry G. ; Pyman, Brian C. ; Roberts, Susan A. ; Tong, Yit C. ; Webb, Robert L. ; Kuzma, Januz A. ; Money, David K. ; Patrick, James F. ; Seligman, Peter M. ( 1987)
    A multiple-electrode intracochlear implant that provides 21 stimulus channels has been designed for use in young children. It is smaller than the adult version and has magnets to facilitate the attachment of the headset. It has been implanted in two children aged 5 and 10 years. The two children both lost hearing in their third year, when they were still learning language. Following implantation, it was possible to determine threshold and comfortable listening levels for each electrode pair. This was facilitated in the younger child by prior training in scaling visual and electrotactile stimuli. Both children are regular users of the implant, and a training and assessment program has been commenced.
  • Item
    Thumbnail Image
    Banded intracochlear electrode array: evaluation of insertion trauma in human temporal bones
    Shepherd, R. K. ; Clark, Graeme M. ; Pyman, B. C. ; Webb, R. L. ( 1985)
    A banded free-fit scala tympani array was inserted into a basal turn of nine human cochleas to evaluate the trauma produced by the procedure. These nine cochleas, together with five nonimplanted controls, were serially sectioned and examined microscopically for damage to the membranous labyrinth, in particular the spiral ligament, the basilar and Reissner’s membranes, the stria vascularis, and the osseous spiral lamina. The severity and location of any trauma along the cochlear spiral were recorded. The results indicate that the insertion of the banded scala tympani array resulted in minimal mechanical damage, occurring primarily to a localized region of the spiral ligament. This would not result in significant neural degeneration, and therefore would not compromise the efficacy of multichannel cochlear prosthesis.
  • Item
    Thumbnail Image
    The clinical trial of a multi-channel cochlear prosthesis
    Pyman, B. C. ; Clark, Graeme M. ; Dowell, R. C. ; Webb, R. L. ; Brown, A. M. ; Bailey, Q. E. ; Luscombe, S. M. ( 1983)
    The results of a multiple-electrode cochlear implant carried out on 1st August, 1978 on a totally deaf patient (post-lingual hearing loss) showed that he could perceive sounds of different pitches depending on the electrode stimulated, and this finding was consistent with the place theory of frequency coding. Furthermore, stimulating individual electrodes produced percepts which the patient described as vowel-like in quality. The patient could also perceive different pitches which varied with the rate of stimulation up to 200 pulses/second, but at higher rates he had difficulties perceiving pitch changes (Clark et al. 1978; Tong et al, 1979). As a result of the psychophysical studies a speech processor was developed. The speech processor extracted: firstly, the voicing frequency to help the patient hear the rhythm of speech and know whether a speech sound was voiced or unvoiced (e.g., /b/ versus /p/); and, secondly, the second formant to enable the patient to recognize vowels and consonants and so hear words. In order to maximize speech intelligibility, the second formant stimulated an appropriate electrode, and the rate of stimulation on that electrode was related to the voicing frequency.
  • Item
    Thumbnail Image
    Surgery for multielectrode cochlear implants
    Lehnhardt, E. ; Laszig, R. ; Webb, H. ; Franz, B. ; Pyman, B. ; Clark, Graeme M. ( 1987)
    For the surgery of the NUCLEUS Cochlear Implant (CI) in general anaesthesia we use a skin cut beginning at the bottom of the entrance to the outer ear canal, following the posterior circumference to a point nearly 12 o'clock. From here the incision runs superiorly to the tragus until two or three centimetres above the pinna base and in a wide smooth circle in direction to the occiput. The wide circle is necessary to get a distance of about 2 cm away from the package and also to guarantee the blood supply by the occipital artery and by the postauricular artery as well.
  • Item
    Thumbnail Image
    Histopathology following electrode insertion and chronic electrical stimulation
    Shepherd, R. K. ; Clark, Graeme M. ; Pyman, B. C. ; Webb, R. L. ; Murray, M. T. ; Houghton, M. E. (Raven Press, 1985)
    We have examined a number of safety issues associated with cochlear implants. This work has been primarily designed to evaluate the histopathological effects of intracochlear electrode implantation and chronic electrical stimulation. The results of these studies may be summarized as follows: 1) The insertion of the banded free-fit scala tympani array into human cadaver temporal bones produces minimal damage, occurring primarily to a localized region of the spiral ligament. This damage would not result in significant neural degeneration and thus, would not compromise the efficacy of the multiple channel device; 2) chronic intracochlear electrical stimulation for continuous periods of 500 to 2000 hours, using charge balanced biphasic current pulses developing charge densities of 18-32 }?C/cm2. geom./phase, does not adversely affect the spiral ganglion cell population; 3) labyrinthine infection severely reduces the viable spiral ganglion cell population; 4) the formation of new bone present in approximately half of the animals we have implanted --is not associated with electrical stimulation per se; 5) scanning electron microscope studies of electrodes subjected to long periods of intracochlear electrical stimulation reveals minimal platinum dissolution when compared with unstimulated control electrodes, and electrodes that have been stimulated for similar periods in inorganic saline.