Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 17
  • Item
    Thumbnail Image
    Threshold shift: effects of cochlear implantation on the risk of pneumococcal meningitis
    Wei, Benjamin P. C. ; Shepherd, Robert K. ; Robins-Browne, Roy M. ; Clark, Graeme M. ; O'Leary, Stephen J. ( 2007)
    Unavailable due to copyright.
  • Item
    Thumbnail Image
    Effects of inner ear trauma on the risk of pneumococcal meningitis
    Wei, Benjamin P. C. ; Shepherd, Robert K. ; Robins-Browne, Roy M. ; Clark, Graeme M. ; O'LEARY, STEPHEN ( 2007)
    Objective: To examine the risk of pneumococcal meningitis in healthy rats that received a severe surgical trauma to the modiolus and osseous spiral lamina or the standard insertion technique for acute cochlear implantation. Design: Interventional animal studies. Subjects: Fifty-four otologically normal adult Hooded- Wistar rats. Interventions: Fifty-four rats (18 of which received a cochleostomy alone; 18, a cochleostomy and acute cochlear implantation using standard surgical techniques; and 18, a cochleostomy followed by severe inner ear trauma) were infected 4 weeks after surgery with Streptococcus pneumoniae via 3 different routes (hematogenous, middle ear, and inner ear) to represent all potential routes of bacterial infection from the upper respiratory tract to the meninges in cochlear implant recipients with meningitis. Results: Severe trauma to the osseous spiral lamina and modiolus increased the risk of pneumococcal meningitis when the bacteria were given via the middle or inner ear (Fisher exact test, P<.05). However, the risk of meningitis did not change when the bacteria were given via the hematogenous route. Acute electrode insertion did not alter the risk of subsequent pneumococcal meningitis for any route of infection. Conclusions: Severe inner ear surgical trauma to the osseous spiral lamina and modiolus can increase the risk of pneumococcal meningitis. Therefore, every effort should be made to ensure that cochlear implant design and insertion technique cause minimal trauma to the bony structures of the inner ear to reduce the risk of pneumococcalmeningitis.
  • Item
    Thumbnail Image
    Assessment of the protective effect of pneumococcal vaccination in preventing meningitis after cochlear implantation
    Wei, Benjamin P. C. ; Robins-Browne, Roy M. ; Shepherd, Robert K. ; AZZOPARDI, KRISTY ; Clark, Graeme M. ; O'Leary, Stephen J. ( 2007)
    Objectives: To examine if a 23-valent pneumococcal capsular polysaccharide vaccine (PPV23) reduces the risk of meningitis in healthy rats after cochlear implantation. Design: Interventional animal study. Interventions: Thirty-six rats (18 immunized and 18 unimmunized) received cochlear implantations and were then infected with Streptococcus pneumoniae via 3 different routes (hematogenous, middle ear, and inner ear) in numbers sufficient to induce meningitis. Results: The rats with implants that received PPV23 were protected from meningitis when the bacteria were delivered via the hematogenous and middle-ear routes (Fisher exact test P<.05). However, the protective effect of the vaccine in the rats with implants was only moderate when the bacteria were inoculated directly into the inner ear. Conclusions: Our animal model clearly demonstrates that immunization can protect healthy rats with a cochlear implant from meningitis caused by a vaccine-covered serotype. This finding supports the notion that all current and future implant recipients should be vaccinated against S pneumoniae.
  • Item
    Thumbnail Image
    Cochlear histopatholgic characteristics following long-term implantation: safety studies in the young monkey
    Burton, Martin J. ; Shepherd, Robert K. ; Clark, Graeme M. ( 1996)
    Objective: To evaluate the safety of cochlear implantation in children 2 years of age or younger using a non-human primate model.
  • Item
    Thumbnail Image
    Electrical stimulation of residual hearing in the implanted cochlea
    Clark, Graeme M. ; McAnally, K. I. ; Black, R. C. ; Shepherd, R. K. ( 1995)
    The average profoundly deaf person using a cochlear implant can now understand more speech than some severely to profoundly deaf people who use a hearing aid. For this reason there will be an increasing need to consider implanting people with residual hearing. In many of these people there could be significant hearing in the operated ear, as a majority of severely to profoundly deaf people are likely to have a symmetrical hearing loss. When three frequency average hearing thresholds were measured on 219 pensioners from the Australian National Acoustic Laboratories (H. Dillon, unpublished findings), 64% had less than a 10-dB difference between thresholds in each ear.
  • Item
    Thumbnail Image
    Cochlear implantation: osteoneogenesis, electrode-tissue impedance, and residual hearing
    Clark, Graeme M. ; Shute, S. A. ; Shepherd, R. K. ; Carter, T. D. ( 1995)
    This study was undertaken to find out how new bone is produced in the implanted cochlea, and the effects of fibrous tissue and new bone growth on electrode-tissue impedance. This knowledge is essential, as bone and fibrous tissue in the cochlea could account for variations in patients' speech perception performance. The study was also carried out to examine the effects of implantation on residual hearing. This information is also important, as cochlear implant speech perception results in profoundly deaf people are now better on average than severely or profoundly deaf people obtain with a hearing aid. Consequently, more people will need to be considered for cochlear implantation in ears with some residual hearing. In this case we need to know to what extent residual hearing is affected by implantation. (From Introduction)
  • Item
    Thumbnail Image
    Temporal coding of frequency: neuron firing probabilities for acoustic and electric stimulation of the auditory nerve
    Clark, Graeme M. ; Carter, T. D. ; Maffi, C. L. ; Shepherd, R. K. ( 1995)
    A better understanding of the temporal coding of frequency, and its application to electrical stimulation of auditory nerve fibers, should lead to advances in cochlear implant speech processing. Past research studies have suggested that the intervals between nerve action potentials are important in the temporal coding of frequency. For sound frequencies up to approximately 500 Hz, the shortest or predominant intervals between the nerve action potentials are usually the same as the periods of the sound waves. The intervals between each nerve action potential can be plotted as an interval histogram. Although there is evidence that the intervals between spikes are important in the temporal coding of frequency, it is not known up to what frequency this applies. It is also not known whether the information transmitted along individual fibers or an ensemble of fibers is important, to what extent the coding of frequency is interrelated with the coding of intensity, the relative importance of temporal and place coding for different frequencies, and finally, how well electrical stimulation can simulate the temporal coding of sound.
  • Item
    Thumbnail Image
    A physiological investigation of chronic electrical stimulation with scala tympani electrodes in kittens
    Ni, Daofeng ; Shepherd, Robert K. ; Clark, Graeme M. ( 1992)
    A physiological investigation of cochlear electrical stimulation was undertaken in six two-month-old kittens. The scala tympani electrodes were implanted and electrically stimulated using biphasic balanced electrical pulses' for periods of 1000-1500h in four ears. Four ears received implants for same period but without electrical stimulation. The other two ears served as normal control. The results indicated: 1) Chronic electrical stimulation of the cochlea within electrochemically safe limits did not influence the hearing of kittens and the normal delivery of impulses evoked by acoustic and electrical signals on the auditory brainstem pathway. 2) The wave shapes of EABRs were similar to those of ABRs. The aptitudes of EABRs showed a significant increase following chronic electrical stimulation, resulting in a leftward shift in the input/ output function. The absolute latencies and interwave latencies of waves II-III , III -IV and II -IV were significantly shorter than those of ABRs. These results imply that there was no adverse effect of chronic electrical stimulation on the maturing auditory systems of kittens using these electrical parameters and the mechanism of electrical hearing should be further studied.
  • Item
    Thumbnail Image
    Experimental study on extracochlear electric stimulation [Abstract]
    Ni, Daofeng ; Shepherd, Robert K. ; Clark, Graeme M. ( 1992)
    The efficiency and feasibility of chronic extracochlear implantation and electric stimulation were studied in two adult cats and four 2-month kittens. The first electrode was placed on the round window by fixing the leadwire on the bridge of aditus between the middle ear and bulla cavity; the second electrode was placed on the surface of the tympanic promontory; the third was inserted into the temporal muscle out of the bulla and the forth fixed in transverse sinus with dental cement. ABRs and EABRs were recorded pre-and postoperatively and during electric stimulation.
  • Item
    Thumbnail Image
    The biologic safety of the Cochlear Corporation multiple-electrode intracochlear implant
    Webb, Robert L. ; Clark, Graeme M. ; Shepherd, Robert K. ; Franz, Burkhard K-H. ; Pyman, Brian C. ( 1988)
    Studies have been undertaken to confirm the biologic safety of the Cochlear Corporation multi-electrode intracochlear implant. The materials used are biocompatible. The electrode array is flexible: it can be inserted with minimal or no trauma, providing the insertion is stopped when resistance is first felt. An atraumatic insertion is facilitated if a good view is obtained along the scala tympani of the basal turn of the cochlea by drilling through the crista fenestrae. The passage of the electrode around the cochlea can be facilitated if the electrode is rotated during insertion (clockwise for the left and anticlockwise for the right cochlea). The electrode can be explanted and another one reinserted with minimal or no trauma. A seal established around the electrode after an implantation period of 2 weeks can prevent infection extending from the middle to the inner ear. The electrical stimulus parameters produced by the Nucleus receiver-stimulator cause no loss of spiral ganglion cells or corrosion of the platinum band electrodes. Long-term stimulation has been carried out for up to 8 years in patients without affecting their clinical performance.