Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 6 of 6
  • Item
    Thumbnail Image
    Comparison of current speech coding strategies
    Whitford, L. A. ; Seligman, P. M. ; Blamey, Peter J. ; McDermott, H. J. ; Patrick, J. F. ( 1993)
    This paper reports on two studies carried out at the University of Melbourne jointly with Cochlear Pty Ltd. The studies demonstrated substantial speech perception improvements over the current Multipeak strategy in background noise.
  • Item
    Thumbnail Image
    Electrode position, repetition rate, and speech perception by early-and-late-deafened cochlear implant patients
    Busby, P. A. ; Tong, Y. C. ; Clark, Graeme M. ( 1993)
    Psychophysical and speech perception studies were conducted on eight patients using the 22electrode cochlear implant manufactured by Cochlear Pty. Ltd. Four early-deafened patients became deafened at 1-3 years of age and were implanted at 5-14 years of age. Four late-deafened (postlingual adult) patients became deafened at 38-47 years of age and were implanted at 42-68 years of age. Psychophysical studies measured the discrimination of trajectories with time-varying electrode positions and repetition rates. Speech perception studies measured performance using two speech coding strategies: a multi-electrode strategy which coded the first and second formant frequencies, the amplitudes of the two formants, and the fundamental frequency; and a single-electrode strategy which coded the amplitudes of the first and second formants, and the fundamental frequency. In general, the four late-deafened patients and one early-deafened patient were more successful than the other three early-deafened patients in the discrimination of electrode position trajectories and in speech perception using the multi-electrode strategy. Three of the four late-deafened patients were more successful than the early-deafened patients in the discrimination of repetition rate trajectories. Speech perception performance in the single-electrode strategy was closely related to performance in repetition rate discrimination. The improvement in speech perception performance from the single-electrode to multi-electrode strategy was consistent with successful performance in electrode discrimination.
  • Item
    Thumbnail Image
    Psychophysical and speech perceptual studies on cochlear implant patients
    Tong, Yit C. ; Lim, H. H. ; Clark, Graeme M. (Springer-Verlag, 1990)
    One of the most important findings in cochlear implant research has been the orderly variation in perceptual characteristics produced by intracochlear electrodes in accordance with the tonotopic organization of the cochlea. The electrical signal dimension of electrode position has therefore been used extensively for presenting speech information to cochlear implant patients. This paper describes further psychophysical and speech perceptual results on the perceptual characteristics produced by intracochlear electrodes.
  • Item
    Thumbnail Image
    Effects of rate and pulse manipulations of the spectral maxima speech processor upon speech production
    Tobey, Emily A. ; Blamey, Peter J. ; McDermott, Hugh J. ; McKay, Colette M ( 1993)
    Postlingually deafened adults experience many changes in their speech as a consequence of late-onset deafness. Previous studies have indicated changes in fundamental frequency, duration, intensity, and vowel formant frequencies in postlingually deafened adults. Postlingually deafened adults who receive multichannel cochlear implants demonstrate improved control of fundamental frequency and intensity. Shifts in formant frequencies to values similar to normal hearing. speakers also appears in some adult implant users. In order to examine how adult implant users adjust their vowel production in response to map changes, we examined vowel production following manipulations to the processing strategy of the Spectral Maxima Speech Processor. This processor uses a speech processing scheme in which six spectral maxima from the outputss of 16 bandpass filters stimulate the cochlea on a place basis at a constant rate. The rate of sampling of the filterbank output is 250 Hz, so six biphasic pulses are presented every 4 msec and there is no attempt to extract fundamental frequency or to find the formant peaks in the speech signal. Two manipulations to the scheme were examined. In the first condition, the rate of sampling remained at 250Hz but eight biphasic pulses were presented rather than six. In the second condition, six biphasic pulses were presented but the rate of sampling of the filterbank output was increased to 400 Hz. Speech samples also were acquired using the standard spectral maxima processor .and with no auditory feedback when the processor was turned off. Speech samples from three �subjects were acquired immediately after receiving the manipulated speech processors and after two weeks experience with the various processors. Preliminary data indicate one subject experienced increased fundamental frequencies while using the 400 Hz high rate strategy. No significant changes were observed in fundamental frequency between the normal SMSP processor and the eight pulse variation. Elimination of feedback resulted in significantly lower fundamental frequencies. The high rate and eight pulse variations resulted in significantly higher first formant frequencies. Second formant frequencies also appear to be influenced by the processing strategies. Comparisons of values produced immediately after receiving a new strategy versus those produced after two weeks use show shifts in primarily first formant values. Data will be presented for all three subjects and discussed in regard to sensitivity to variations in speech processing schemes and the influence of experience with manipulated schemes. (Work supported by the N1H-NIDCD).
  • Item
    Thumbnail Image
    Fricative perception by cochlear implant users
    Blamey, P. J. ; Tartter, V. C. ( 1992)
    Three implant users were tested with 45 syllables consisting of[v, f, �, ?, z, s, ?, ?, d?, t ?, ?, , d, n, 1] before the vowels [I ,a,u] with three wearable speech processors. The WSP3 processor coded first and second formant frequencies and amplitudes. The MSP1 processor used a similar scheme with improved measurement and coding of the formants. The MSP2 processor added amplitude information from three higher frequency bands. Average scores were 42% for WSP3, 54% for MSP1, and 57% for MSP2. Perception of voicing, manner, and place of articulation of the consonants was significantly greater for the MSP processors than the WSP3 processor. Place perception was slightly higher for MSP2 than MSP1. The listeners used three perceptual dimensions which were highly correlated with the frequencies and amplitudes of peaks in the low frequency region of the frication spectrum, amplitudes of high frequency peaks, and duration of the frication noise.
  • Item
    Thumbnail Image
    Comparative performance of children using the cochlear 22-channel implant and 8-channel 'Tickle Talker'
    Cowan, Robert S. C. ; Sarant, S. J. ; Dettman, K. L ; Galvin, K. L. ; Blamey, P. J. ; Clark, Graeme M. ( 1992)
    Direct comparison of "Tickle Talker" and Cochlear Implant users is problematic, due to difficulties in matching groups of children for hearing loss, age, duration of deafness, speech perception and language skills, and educational placement. However, two studies were undertaken to compare and contrast potential benefits available from these two devices. In the first study, a number of children from one educational setting were evaluated over a six month period. Half of the children used the multiple channel cochlear implant, while the other half used the multiple channel "Tickle Talker". The number of training sessions, clinicians involved, type of training provided, and overall management philosophy were identical for both devices. Comparison of progress of these two groups of children demonstrates that both devices are effective in improving' communication. However, differences were found with the tactile device being more limited in information provided and speech perception benefits. In the second study, two children who have used both devices were evaluated. These two children initially used the ''Tickle Talker" for periods up to two years, and subsequently had a multiple-channel cochlear implant. Similar habilitation was provided to these children with both devices, and measures of speech perception were taken at similar time periods. Results for one of the children, a prelinguistically deafened adolescent, already show similar benefits in terms of supplementation of lipreading for both devices. However, this patient has also shown some open-set word and sentence perception using the implant-alone. To date, this level of performance has not been achieved with the ''Tickle Talker". The results of these studies suggest a role for a multiple channel tactile device in a cochlear implant clinic as a training device for evaluating the ability of adults or children to integrate speech information presented through different sensory modalities. This could facilitate pre-implant evaluation of the potential for children to benefit from added speech information, which is often difficult to evaluate in congenitally deaf children.