Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 17
  • Item
    Thumbnail Image
    A review of the biological, psychophysical, and speech processing principles used to design the tickle talker
    Blamey, P. J. ; Cowan, R. S. C. ; Alcantara, J. I. ; Whitford, L. A. ; Galvin, K. L. ; Sarant, J. Z. ; Clark, Graeme M. ( 1992)
    The Tickle Talker is a wearable electrotactile speech processor, designed to be used by profoundly hearing-impaired children and adults in conjunction with lipreading and residual hearing. The effectiveness of such a device is affected by an interaction between biological, human engineering, psychophysical, and speech processing considerations. The requirements, the design principles, and the performance of the Tickle Talker in each of these areas will be discussed. Electrical stimulation of the nerve bundles lying along the sides of the fingers was chosen to provide safe, comfortable, energy-efficient stimulation of a well-organised and sensitive part of the tactile sensory system. This is achieved at a small cost to the appearance and mobility of one hand when using the Tickle Talker. The biphasic pulse waveform used to stimulate the nerve bundles has been chosen to ensure a biologically safe stimulus. The electrical parameters (pulse duration, pulse rate, and electrode position) that are used to encode speech information are varied within ranges that are matched to the characteristics of the tactile sense. The usable ranges and information-carrying potential of each of these parameters have been assessed in psychophysical experiments. A comparison of these results with similar experimental data for cochlear implant and hearing aid users is instructive in assessing the possible limitations of tactile and auditory speech processors. The results discussed will include the discrimination and identification of stimuli differing in intensity, duration and pulse rate; the identification of different spatial patterns of stimulation, and the detection of gaps in stimuli. In most respects, the tactile results are similar to the corresponding auditory measures. The resolution of temporal differences such as pulse rate discrimination or gap detection are generally not as good as in the auditory case, but may be as good or better than the corresponding results for some profoundly hearing-impaired individuals. The speech processor used in the Tickle Talker is a "feature extraction" device that explicitly estimates the second formant frequency, amplitude envelope, and fundamental frequency of the voice and encodes them in terms of electrode position, pulse width and pulse rate of the electrical stimulation pattern. Consideration of the psychophysical results and the speech information available from these parameters allows optimization of the Tickle Talker's operation and a broad estimation of its potential performance in speech discrimination. The perception of duration and place of articulation (front/back) of vowels, and the manner and voicing of consonants are expected to be improved by the Tickle Talker. Prosodic variations conveyed by pulse rate are expected to be perceived by some users, but not all. High frequency consonants such as: /s/,/z/./?/, and /t?/ are encoded in a particularly salient manner by the Tickle Talker.
  • Item
    Thumbnail Image
    Experimental study on extracochlear electric stimulation [Abstract]
    Ni, Daofeng ; Shepherd, Robert K. ; Clark, Graeme M. ( 1992)
    The efficiency and feasibility of chronic extracochlear implantation and electric stimulation were studied in two adult cats and four 2-month kittens. The first electrode was placed on the round window by fixing the leadwire on the bridge of aditus between the middle ear and bulla cavity; the second electrode was placed on the surface of the tympanic promontory; the third was inserted into the temporal muscle out of the bulla and the forth fixed in transverse sinus with dental cement. ABRs and EABRs were recorded pre-and postoperatively and during electric stimulation.
  • Item
    Thumbnail Image
    Speech perception, production and language results in a group of children using the 22-electrode cochlear implant
    Blamey, P. J. ; Dawson, P. W. ; Dettman, S. J. ; Rowland, L. C. ; Brown, A. M. ; Busby, P. A. ; Dowell, R. C. ; Rickards, F. W. ; Clark, Graeme M. ( 1992)
    Five children out of a group of nine (aged 5.5 to 19.9 years) implanted with the 22-electrode cochlear implant (Cochlear Ply. Ltd.) have achieved substantial scores on open-set speech tests using hearing without lipreading. Phoneme scores for monosyllabic words ranged from 40% to 72%. Word scores in sentences ranged from 26% to 74%. Four of these five children were implanted during preadolescence. The fifth child, who had a progressive loss and was implanted during adolescence after a short period of very profound deafness, scored highest on all speech perception tests. The remaining four children who did not demonstrate open-set recognition were implanted during adolescence after a long duration of profound deafness. Post-operative performance on closed-set speech perception tests was better than pre-operative performance for all children. Improvements in speech and language assessments were also noted. These improvements tended to be greater for the younger children. The results are discussed with reference to variables which may contribute to successful implant use: such as age at onset, duration of profound hearing loss, age at implantation, aetiology, educational program, and the type of training provided.
  • Item
    Thumbnail Image
    Comparison of current speech coding strategies
    Whitford, L. A. ; Seligman, P. M. ; Blamey, Peter J. ; McDermott, H. J. ; Patrick, J. F. ( 1993)
    This paper reports on two studies carried out at the University of Melbourne jointly with Cochlear Pty Ltd. The studies demonstrated substantial speech perception improvements over the current Multipeak strategy in background noise.
  • Item
    Thumbnail Image
    A new portable sound processor for the University of Melbourne/ Nucleus Limited multielectrode cochlear implant
    McDermott, Hugh J. ; McKay, Colette M. ; Vandali, Andrew E. ( 1992)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Place pitch perception with multiple electrode cochlear implants: the use of concurrent activation of nearby electrodes to produce additional ptich percepts [Abstract]
    McDermott, Hugh J. ; McKay, Colette M. ( 1992)
    In multiple electrode cochlear implants, each electrode produces a pitch percept which is usually related monotonically to its distance from the round window. The number of these pitch percepts is limited by the number of usable electrodes and their discriminability, varying up to a maximum of 22 for the mini-system 22 implant but sometimes significantly less. A study on two implanted subjects in which the pitch of pulse trains on two concurrently activated nearby electrodes was compared with the pitch produced when each of the electrodes was activated on its own, showed that the pitch of the concurrently activated electrodes was different from each component electrode and was placed in an intermediate position. Furthermore the pitch of the concurrent stimulation could be altered by adjusting the relative current levels on the two component electrodes. This may partly explain the improvements, particularly in vowel discrimination, obtained with the SMSP strategy described in the accompanying paper.
  • Item
    Thumbnail Image
    The perception of temporal modulations by cochlear implant patients
    Busby, P. A. ; Tong, Y. C. ; Clark, Graeme M. ( 1993)
    The perception of temporal modulations of pulsatile electric stimuli was measured in seven cochlear implant patients using the Cochlear Pty. Limited prosthesis. Four patients were postlingually deafened adults and three patients were young adults who were deafened very early in life. The first study measured detection thresholds for modulated pulse duration for a series of modulation frequencies and pulse rates. The shape of the detection thresholds as a function of modulation frequency, the temporal modulation transfer function, often resembled a low-pass filter with a 50-100-Hz cut-off frequency. Thresholds did not markedly vary across the different pulse rates for most patients. Thresholds were less than 10%-20% of the range of usable hearingfor most patients. The second study compared detection thresholds for modulated pulse durations around different reference pulse durations: 50, 100, and 300 J.Ls. Detection thresholds were generally proportional to the different reference pulse durations. The third study measured difference limens for the discrimination of modulation depth. The difference limens were similar to the detection thresholds for the same reference pulse duration and pulse rate. The three patients deafened very early in life showed more within-group variation in performance, and their overall levels of performance were poorer than those of the postlingually deafened adults.
  • Item
    Thumbnail Image
    Electrode position, repetition rate, and speech perception by early-and-late-deafened cochlear implant patients
    Busby, P. A. ; Tong, Y. C. ; Clark, Graeme M. ( 1993)
    Psychophysical and speech perception studies were conducted on eight patients using the 22electrode cochlear implant manufactured by Cochlear Pty. Ltd. Four early-deafened patients became deafened at 1-3 years of age and were implanted at 5-14 years of age. Four late-deafened (postlingual adult) patients became deafened at 38-47 years of age and were implanted at 42-68 years of age. Psychophysical studies measured the discrimination of trajectories with time-varying electrode positions and repetition rates. Speech perception studies measured performance using two speech coding strategies: a multi-electrode strategy which coded the first and second formant frequencies, the amplitudes of the two formants, and the fundamental frequency; and a single-electrode strategy which coded the amplitudes of the first and second formants, and the fundamental frequency. In general, the four late-deafened patients and one early-deafened patient were more successful than the other three early-deafened patients in the discrimination of electrode position trajectories and in speech perception using the multi-electrode strategy. Three of the four late-deafened patients were more successful than the early-deafened patients in the discrimination of repetition rate trajectories. Speech perception performance in the single-electrode strategy was closely related to performance in repetition rate discrimination. The improvement in speech perception performance from the single-electrode to multi-electrode strategy was consistent with successful performance in electrode discrimination.
  • Item
    Thumbnail Image
    Psychophysical and speech perceptual studies on cochlear implant patients
    Tong, Yit C. ; Lim, H. H. ; Clark, Graeme M. (Springer-Verlag, 1990)
    One of the most important findings in cochlear implant research has been the orderly variation in perceptual characteristics produced by intracochlear electrodes in accordance with the tonotopic organization of the cochlea. The electrical signal dimension of electrode position has therefore been used extensively for presenting speech information to cochlear implant patients. This paper describes further psychophysical and speech perceptual results on the perceptual characteristics produced by intracochlear electrodes.
  • Item
    Thumbnail Image
    Fricative perception by cochlear implant users
    Blamey, P. J. ; Tartter, V. C. ( 1992)
    Three implant users were tested with 45 syllables consisting of[v, f, �, ?, z, s, ?, ?, d?, t ?, ?, , d, n, 1] before the vowels [I ,a,u] with three wearable speech processors. The WSP3 processor coded first and second formant frequencies and amplitudes. The MSP1 processor used a similar scheme with improved measurement and coding of the formants. The MSP2 processor added amplitude information from three higher frequency bands. Average scores were 42% for WSP3, 54% for MSP1, and 57% for MSP2. Perception of voicing, manner, and place of articulation of the consonants was significantly greater for the MSP processors than the WSP3 processor. Place perception was slightly higher for MSP2 than MSP1. The listeners used three perceptual dimensions which were highly correlated with the frequencies and amplitudes of peaks in the low frequency region of the frication spectrum, amplitudes of high frequency peaks, and duration of the frication noise.