Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 26
  • Item
    Thumbnail Image
    A multiple-channel cochlear implant: an evaluation using open-set CID sentences
    Clark, Graeme M. ; Tong, Yit Chow ; Martin, Lois F. A. ( 1981)
    A multiple-channel cochlear implant and speech processor have been used in two postlingually deaf adult patients with a total hearing loss, to enable them to perceive varying degrees of running speech. The results have been confirmed with open-set CID everyday sentence tests. Using the implant alone, the patients obtained 8% and 14% scores with pre-recorded material, and 34% and 36% scores for "live" presentations. This was equivalent to the perception of 35% of connected discourse. When the implant was used in conjunction with lipreading, improvements of 188% and 386% were obtained over lipreading alone, and the scores were 68% and 98% which were equivalent to the perception of 60% and 95% of connected discourse.
  • Item
    Thumbnail Image
    Speech processing for a multiple-channel cochlear implant
    Tong, Y. C. ; Millar, J. B. ; Clark, Graeme M. ; Martin, L. F. ; Busby, P. A. ( 1980)
    A laboratory speech processor has been developed for a multiple-channel cochlear implant prosthesis. The speech processor accepts the speech waveform as an input and produces a pattern of electrical stimulus data as output. The electrical stimulus data are transmitted to the implanted receiver-stimulator by a transmitter which is external to the speech processor. Four speech signal parameters were estimated every 20 ms in the parameter estimation section of the speech processor. These parameters included the fundamental frequency (FO), a low frequency energy measure (AO) , the second formant frequency (F2) and its amplitude (A2).
  • Item
    Thumbnail Image
    Speech processing for a multiple-electrode cochlear implant hearing prosthesis
    Tong, Y. C. ; Clark, Graeme M. ; Seligman, P. M. ; Patrick, J. F. ( 1980)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Speech processing for a totally deaf patient with a multiple-electrode cochlear implant [Abstract]
    Clark, Graeme M. ; Tong, Y. C. ; Millar, J. B. ; Martin, L. F. ; Busby, P. A. ( 1980)
    A patient with a total hearing loss had a multiple-electrode cochlear implant performed on 1 August 1978 (Clark et. Al. 1979). Preliminary findings (Tong et al 1979) have shown that low and high pitch are discriminated on a place basis. Stimulating different electrodes produced the vowel colours.......
  • Item
    Thumbnail Image
    Design criteria of a multiple-electrode cochlear implant hearing prosthesis
    Clark, Graeme M. ; Black, R. C. ; Forster, I. C. ; Patrick, J. F. ; Tong, Y. C. ( 1978)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Issues in long-term management of children with cochlear implants and tactile devices [Abstract]
    COWAN, ROBERT ; DOWELL, RICHARD ; Barker, Elizabeth ; GALVIN, KARYN ; DETTMAN, SHANI ; SARANT, JULIA ; RANCE, GARY ; Hollow, Rod ; BLAMEY, PETER ; Clark, Graeme M. ( 1994)
    For many children with severe and profound hearing losses, conventional hearing aids are unable to provide sufficient amplification to ensure good oral communication and/or in the case of very young children, development of speech and language. Traditionally a number of these children have opted for the use of sign language alone or in Total Communication approaches as a primary means of communication. The advent of multiple channel cochlear implants for children and the continuing development of multiple channel speech processing tactile devices provide auditory approaches to resolving communication difficulties for these children. The successful use of such devices depends on a number of factors including the information provided through the aid; the ease of use, convenience and reliability of the aid; the individual communication needs of the child; and the habilitation and management program used with the device. Long-term data has shown that children continue to show increased speech perception benefits from improvements in speech processing and from further experience with these devices. Habilitation and management programs must therefore be geared to meet the changing needs of children as they progress and of families as children mature and face new challenges. Habilitation must address specific individual needs in speech perception and in speech production. For very young children, benefits of improved speech perception should have an impact on the development of speech and language, and habilitation and management must emphasise the need for language growth.
  • Item
    Thumbnail Image
    Combined cochlear implant and speech processing hearing aid for implant users with a severe to profound hearing loss in the contralateral ear [Abstract]
    BLAMEY, PETER ; Parisi, Elvira ; Dooley, Gary ( 1994)
    The bimodal device was developed for cochlear implant users who simultaneously wear a hearing aid in the opposite ear having residual hearing of a severe to profound degree. The aim was to create a single device to provide both input signals in a more compatible manner and thus maximise use of the individual's total hearing capabilities. The acoustic component of the bimodal device is very flexible and can implement various speech processing strategies with speed, ease and precision. The Frequency Response Tailoring strategy utilises three filters to fit a frequency gain curve to within 1-2 dB of that desired. Modifications at discrete frequencies, ranges or slopes can be readily made. The Peak Sharpening or Spectral Enhancement strategy amplifies the formant peaks in speech for potential improvement of formant resolution and speech perception in the presence of background noise. The Resynthesis strategy presents specifically selected components of speech in selected combinations and includes the ability to transpose higher frequency information to lower frequency ranges for individuals with no aidable high frequency hearing levels. Different fits can be quickly and easily interchanged for comparison and evaluation and subsequent modifications indicated can be readily effected. Any combination of acoustic and implant speech processing strategy can be presented to optimise speech perception for the individual user.
  • Item
    Thumbnail Image
    Psychophysics of electrical stimulation of the auditory nerve: implications for coding of sound and speech processing for cochlear implants [Keynote address]
    Clark, Graeme M. ( 1994)
    Psychophysical studies on electrical stimulation of the auditory nerve have contributed to our understanding of the coding of sound and speech signals. Those studies have also helped establish speech processing strategies for multiple-electrode cochlear implant patients. The first studies were on temporal coding of frequency and pitch perception to help determine whether a single or multiple electrode implant would be preferable for the coding of speech frequencies. Temporal frequency coding was initially studied in the experimental animal by measuring difference limens for frequency of stimulus rate. The results showed that rate coding occurs for low frequencies up to 200 or even 600 pulses per second. It was concluded that higher speech frequencies cannot be conveyed by variations in stimulus rate but require multiple-electrode stimulation. These studies in experimental animals were essentially confirmed in the human.
  • Item
    Thumbnail Image
    Evaluation of a new Spectral Peak coding strategy for the Nucleus 22 channel cochlear implant system
    Skinner, Margaret W. ; Clark, Graeme M. ; Whitford, Lesley A. ; Seligman, Peter M. ; Staller, Steven J. ; Shipp, David B. ; Shallop, Jon K. ; Everingham, Colleen ; Menapace, Christine M. ; Arndt, Patti L. ; Antogenelli, Trisha ; Brimacombe, Judith A. ; Pijl, Sipke ; Daniels, Paulette ; George, Catherine R. ; McDermott, Hugh J. ; Beiter, Anne L. ( 1994)
    Sixty-three postlinguistically deaf adults from four English-speaking countries participated in a 17-week field study of performance with a new speech coding strategy, Spectral Peak (SPEAK), and the most widely used strategy, Multipeak (MPEAK), both of which are implemented on wearable speech processors of the Nucleus 22 Channel Cochlear Implant System; MPEAK is a feature-extraction strategy, whereas SPEAK is a filterbank strategy. Subjects' performance was evaluated with an experimental design in which use of each strategy was reversed and replicated (ABAB). Average scores for speech tests presented sound-only at 70 dB SPL were higher with the SPEAK strategy than with the MPEAK strategy. For tests in quiet, mean scores for medial vowels were 74.8 percent versus 70.1 percent; for medial consonants, 68.6 percent versus 56.6 percent; for monosyllabic words, 33.8 percent versus 24.6 percent; and for sentences, 77.5 percent versus 67.4 percent. For tests in noise, mean scores for Four-Choice Spondees at +10 and +5 dB signal-to-noise ratio (S/N) were 88.5 percent versus 73.6 percent and 80.1 percent versus 62.3 percent, respectively; and for sentences at +15 dB, +10, and +5 dB S/N, 66.5 percent versus 43.4 percent, 61.5 percent versus 37.1 percent, and 60.4 percent versus 31.7 percent, respectively. Subjects showed marked improvement in recognition of sentences in noise with the new SPEAK filterbank strategy. These results agree closely with subjects' responses to a questionnaire on which approximately 80 percent reported they heard best with the SPEAK strategy for everyday listening situations.
  • Item
    Thumbnail Image
    Loudness growth characteristics of cochlear implantees using the Spectral Maxima Sound Processor [Abstract]
    MCDERMOTT, HUGH ; MCKAY, COLETTE ( 1994)
    The study of perceptual characteristics of subjects with cochlear implants can lead to improvements in the design of speech processors. One important aspect of speech processing which has received little attention in the past is the conversion acoustic signal amplitudes into appropriate levels of electrical stimulation. The optimum conversion would provide implantees with loudness growth characteristics that mimic those of normal hearing. To investigate how implantees using the Spectral Maxima Sound Processor (SMSP) perceive changes in loudness, an experiment involving production of fixed loudness ratios was conducted. Ten subjects participated: five users of the Mini System 22 cochlear implant, and five normally-hearing subjects. In the experiment, the subjects were required to adjust the loudness of two stimuli (white noise and speech-weighted noise) to equal half or twice that of a reference. The reference was presented at various levels over a range of 25 to 75 dBA. The results for three of the implantees were similar to those of all the normally-hearing subjects, who produced an average level change of 10.8 dB for the task. The remaining subjects, who had the largest electrical dynamic ranges, produced larger level changes (up to 20 dB) which were constrained by the limited electrical dynamic range of the processor (46 dB). The SMSP utilises an amplitude conversion function by which the stimulus level (in dB) is directly proportional to the input sound level (in dB). The experimental results suggest that the shape of this function is satisfactory, though not necessarily optimum, for these implantees.