  • Item
    Thumbnail Image
    Chronic electrical stimulation of the auditory nerve at high rates: I. Effect on residual hearing [Abstract]
    Xu, J. ; Shepherd, R. K. ; Clark, Graeme M. ( 1996)
    In addition to direct excitation of auditory nerve fibres, cochlear implant patients with small amounts of residual hearing may receive important additional auditory cues via electrophonic activation of hair cells 1. Before incorporating electrophonic hearing into speech processing strategies, the extent of hair cell survival following cochlear implantation must first be determined. We have recently demonstrated widespread survival of hair cells apical to electrode arrays implanted for periods of up to three years, the present report describes the effects of chronic electrical stimulation on hair cell survival.
  • Item
    Thumbnail Image
    Chronic electrical stimulation of the auditory nerve at high rates: II. Cochlear pathophysiology [Abstract]
    Shepherd, R. K. ; Xu, J. ; Clark, Graeme M. ( 1996)
    A major factor in the improved performance of cochlear implant patients has been the use of high stimulus rate speech processing strategies. While these strategies show clear clinical advantage, we know little of their long-term safety. Indeed, recent studies have indicated that high stimulus rates at intensities above clinical limits, can result in neural damage as a result of prolonged neuronal hyperactivity. The present study was designed to evaluate the effects of chronic electrical stimulation of the auditory nerve at high rates, using intensities within clinical limits.
  • Item
    Thumbnail Image
    Spatial representation of the cochlea within the inferior colliculus of neonatally deafened kittens following chronic electrical stimulation of the auditory nerve [Abstract]
    Shepherd, R. K. ; Martin, R. L. ; Brown, M. ; Clark, Graeme M. ( 1995)
    The orderly tonotopic representation of the cochlea is accurately reproduced within the central auditory system of normal hearing animals. Any degradation of this representation as a result of a neonatal hearing loss or chronic electrical stimulation during development could have important implications for the use of multichannel cochlear implants in young children. In the present study we have used 2-deoxyglucose autoradiography (2-00) to examine the topographic representation of the cochlea within the inferior colliculus (IC) of neonatally deafened kittens following periods of chronic intracochlear electrical stimulation.
  • Item
    Thumbnail Image
    Intracellular responses of anteroventral cochlear nucleus neurones to intracochlear electrical stimulation in the rat [Abstract]
    Paolini, A. G. ; Clark, Graeme M. ( 1996)
    The anterior division of the ventral cochlear nucleus (AVCN) is the first relay station of the auditory pathway. Currently little is known about the intracellular physiological responses of neurones in the AVCN to electrical stimulation of the cochlea. We investigated the effect of cochlear electrical stimulation in the rat AVCN using in vivo intracellular recordings. Male rats were anaesthetised with urethane (1.3g/kg i.p), placed in a stereotaxic frame, the crania and dura removed and the cochlear nucleus exposed.
  • Item
    Thumbnail Image
    Electrophonically driven single unit responses of the anteroventral cochlear nucleus in cat [Abstract]
    Morrison, N. A. ; Brown, M. ; Clark, Graeme M. ( 1996)
    Electrical stimulation of the cochlea results in both direct and electrophonic excitation of auditory nerve fibres. It has been proposed that electrophonic stimulation results from the creation of a mechanical disturbance on the basilar membrane which has properties similar those resulting from acoustic stimuli. Auditory nerve compound action potential (CAP) forward masking studies1 show the level of frequency specific electrophonic stimulation is highly correlated with the spectral energy of the electrical stimulus waveform. The level of spectral energy in pulsatile biphasic electrical stimuli decreases toward low frequencies suggesting the level of electrophonic stimulation will be diminished in the low frequency region of the cochlea.
  • Item
    Thumbnail Image
    The pitch of amplitude-modulated electrical stimuli in cochlear implantees [Abstract]
    McKay, Colette M. ; McDermott, Hugh J. ; Clark, Graeme M. ( 1993)
    The ability of cochlear implantees to detect amplitude modulation of pulsatile electrical stimulation, suggests that some speech feature information may be conveyed effectively by this means. For example, modulations at the fundamental frequency of speech may provide a voice pitch percept to implantees, particularly in speech processing strategies which generate constant-rate stimulation. The pitch evoked by sinusoidally modulated current pulse trains on a single electrodes has been studied. Modulation frequencies of 100, 150 and 200Hz, and carrier pulse rates varying from 200 to 1200Hz, were used. The results showed that the pitch of the stimulation was related to the modulation frequency, provided that either the carrier rate was a multiple of the modulation frequency, or the carrier rate was sufficiently high (at least four times the modulation frequency for the stimuli studied here). Furthermore, when the modulated stimuli were matched in pitch to non-modulated pulse trains, it was. found that the rate of the matched non-modulated stimuli was close to but somewhat higher than the modulation frequency. This difference depended on the carrier rate and varied among subjects.
  • Item
    Thumbnail Image
    A "Combionic Aid": Combined speech processing for a cochlear implant in one ear and speech processing hearing aid in the other ear [Abstract]
    Dooley, Gary J. ; Blamey, Peter J. ; Seligman, Peter M. ; Clark, Graeme M. ( 1993)
    Independent use of a cochlear implant in one ear and a hearing aid in the other is not acceptable for many implant users with some residual hearing. Psychophysical evidence suggests that there are substantial interactions between acoustic and electrical signals including masking and loudness summation. These effects may contribute to the difficulty in using two independent devices and it is desirable to control the parameters of the electrical and acoustical signals far more accurately than is possible with two independent devices with separate microphones. In order to achieve this control we have developed a Combionic aid incorporating an implant and an 'in1planlcompatible' hearing aid controlled from the same speech processor. The new processor is particularly flexible and can implement a wide variety of speech processing strategies for combined acoustic and electrical stimulation. A benchtop prototype has been tested with five patients using a range of different speech tests. In general, patients do better when they use acoustic and electrical information simultaneously than they do with either alone. Some patients on some tests perform significantly better with the bimodal aid than they do with independent hearing aids and implant processors worn together. Wearable devices have now been built and evaluations of these devices are continuing.
  • Item
    Thumbnail Image
    Benefits of pre-curved electrode arrays for the Nucleus multichannel cochlear implant [Abstract]
    Pyman, B. ; Clark, Graeme M. ; Saunders, Elaine ; Cohen, Lawrence T. ; Cowan, Robert S. C. ; Treaba, C. ; Dahm, M. ; Tykocinski, M. ( 1998)
    The purpose of the study was to evaluate whether placement of an electrode closer to the modiolus would provide a more efficient interface with the auditory nerve. A pre-curved, banded 22-electrode array has been developed. Following comprehensive safety studies, the array was inserted in three adult patients. Detailed x-ray analyses have been conducted to specify the positions of the electrode bands. Psychophysical studies have been conducted, within each subject, using electrodes which lie at differing distances from the modiolus. These studies have shown that as the distance from the modiolus decreased, electrode threshold currents decreased and dynamic ranges increased. Thresholds were lower than in a comparison group of standard array users. Forward masking studies showed current spread to be more focused at the electrodes lying closer to the modiolus. Electrode discrimination was also better at electrodes closer to the modiolus. JND for loudness, expressed as a function of dynamic range also decreased in this condition. Thus, a preliminary profile of the parameters of interest, for an improved implant design, suggest that an array which lies closer to the modiolus can result in lower current requirements and a more localised pattern of neural excitation.
  • Item
    Thumbnail Image
    Speech perception & indirect benefits for severely hearing impaired children using cochlear implants [Abstract]
    Cowan, Robert S. C. ; Dowell, Richard C. ; Nott, P. ; Rennie, Maree ; Pyman, B. ; Clark, Graeme M. ( 1998)
    The benefits to speech perception, speech production, communication, and quality of life were investigated for severely hearing impaired children using cochlear implants and hearing aids. For the youngest children, assessments of psychological status, and use of a battery of cognitive and language tests were important factors in determining performance benefits prior to the child developing speech. For older children, the effects of increased one-to-one oral habilitation, and systematic encouragement of parental involvement were also investigated. Results suggested that parental support for consistent device use was an important factor in producing outcomes. Children with residual hearing were more likely to achieve open-set perception. Each child was also assessed for changes in quality of life, through use of a standardized health utility instrument. Results from the group were collated, and teamed with a costing assessment for the procedure, which allowed a complete cost-utility analysis to be completed. Results suggested that indirect benefits, such as the effects on speech production, usual activities, lower concentration, and less distress were ranked as more important than changes to hearing in a number of the children. Costs per QALY were consistent with those reported in the literature, and suggested that the cochlear implant is highly cost-effective as a medical technology.
  • Item
    Thumbnail Image
    Spatial spread of neural excitation in cochlear implants: comparison of measurements made using NRT and forward masking [Abstract]
    Cohen, L. T. ; Saunders, E. ; Cone-Wesson, Barbara ; Clark, Graeme M. ( 1998)
    Recently developed technology allows intracochlear potentials to be measured in cochlear implant recipients, using telemetry. Neural response telemetry (NRT) enables the measurement of compound action potentials evoked by stimulation of cochlear implant electrodes. These objective measures can now be compared with related psychophysical measures in humans. We will present data, from both NRT and forward masking, on spatial spread of neural excitation due to stimulation of cochlear implant electrodes. The response fields from more apical neurons will spread quite broadly to the sensing electrodes of an implanted array, resulting in misleadingly broad NRT estimates of the spatial spread of neural excitation. Forward masking, which might itself lay claims to some degree of "objectivity", will not suffer from this limitation. Comparison of data from the two measures will help to determine the limitations of NRT as a tool for measuring spatial spread of neural excitation.