    Speech perception as a function of electrical stimulation rate: using the nucleus 24 cochlear implant system
    Vandali, Andrew E. ; Whitford, Lesley A. ; Plant, Kerrie L. ; Clark, Graeme M. ( 2000)
    Objective: To investigate the effect of varying electrical stimulation rate on speech comprehension by cochlear implant users, while keeping the number of stimulated channels constant. Design: Three average rates of electrical stimulation,250, 807, and 1615 pulses per second per channel (pps/ch), were compared using a speech processing strategy that employed an electrode selection technique similar to that used in the Spectral Maxima Sound Processor strategy (McDermott, McKay,& Vandali, 1992; McDermott & Vandali, Reference Note 1; McKay, McDermott, Vandali, & Clark, 1991)and the Spectral Peak strategy (Skinner et al., 1994;Whitford et al., 1995). Speech perception tests with five users of the Nucleus 24 cochlear implant system were conducted over a 21-wk period. Subjects were given take-home experience with each rate condition. A repeated ABC evaluation protocol with alternating order was employed so as to account for learning effects and to minimize order effects. Perception of open-set monosyllabic words in quiet and open-set sentences at signal to noise ratios ranging from +20 to 0 dB, depending on the subject’s ability, were tested. A comparative performance questionnaire was also administered. Results: No statistical differences in group performance between the 250 and 807 pps/ch rates were observed in any of the speech perception tests. However, significantly poorer group performance was observed for the 1615 pps/ch rate for some tests due predominantly to the results of one subject. Analysis of individual scores showed considerable variation across subjects. For some subjects, one or more of the three rate conditions evaluated provided benefits on some speech perception tasks. The results of the comparative performance questionnaire indicated a preference for the 250 and 807pps/ch rates over the 1615 pps/ch rate for most listening situations. Conclusions: For the speech processing strategy, implant system, and subjects evaluated in this study, the group results indicated that the use of electrical stimulation rates higher than 250 pps/ch (up to 1615 pps/ch) generally provided no significant improvement to speech comprehension. However, individual results indicated that perceptual.
  • Item
    Thumbnail Image
    Speech results with a bilateral multi-channel cochlear implant subject for spatially separated signal and noise
    van Hoesel, Richard J. M. ; Clark, Graeme M. ( 1999)
    Speech tests in noise were administered to a bilaterally implanted cochlear implant subject. Performance for simultaneous use of two identical implants, with the same speech processing strategy on two independent standard clinical processors, was compared with that of the better performing monaural side alone. Speech was presented at an angle of 45 degrees toward one ear, with noise at 45 degrees toward the contralateral side. Tests were also administered for speech and noise reversed in location. When the speech signal was on the same side as the subject's better performing ear, monaural and binaural tests resulted in similar scores. When the speech was on the opposite side, however, the binaural condition showed significantly better speech scores. The results indicate that binaural implants can provide improved performance in noise when speech and noise arc spatially separated.
  • Item
    Thumbnail Image
    Research advances for cochlear implants
    Clark, Graeme M. ( 1998)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Electrical stimulation of the auditory nerve: the coding of frequency, the perception of pitch and the development of cochlear implant speech processing strategies for profoundly deaf people
    Clark, Graeme M. ( 1996)
    1. The development of speech processing strategies for multiple-channel cochlear implants has depended on encoding sound frequencies and intensities as temporal and spatial patterns of electrical stimulation of the auditory nerve fibres so that speech information of most importance for intelligibility could be transmitted. 2. Initial physiological studies showed that rate encoding of electrical stimulation above 200 pulses/s could not reproduce the normal response patterns in auditory neurons for acoustic stimulation in the speech frequency range above 200 Hz and suggested that place coding was appropriate for the higher frequencies. 3. Rate difference limens in the experimental animal were only similar to those for sound up to 200 Hz. 4. Rate difference limens in implant patients were similar to those obtained in the experimental animal. 5. Satisfactory rate discrimination could be made for durations of 50 and 100 ms, but not 25 ms. This made rate suitable for encoding longer duration suprasegmental speech information, but not segmental information, such as consonants. The rate of stimulation could also be perceived as pitch, discriminated at different electrode sites along the cochlea and discriminated for stimuli across electrodes. 6. Place pitch could be scaled according to the site of stimulation in the cochlea so that a frequency scale was preserved and it also had a different quality from rate pitch and was described as tonality. Place pitch could also be discriminated for the shorter durations (25 ms) required for identifying consonants. 8. As additional speech frequencies have been encoded as place of stimulation, the mean speech perception scores have continued to increase and are now better than the average scores that severely-profoundly deaf adults and children with some residual hearing obtain with a hearing aid.
  • Item
    Thumbnail Image
    Continuing improvements in speech processing for adult cochlear implant patients
    Hollow, R. D. ; Dowell, R. C. ; Cowan, R. S. C. ; Skok, M. C. ; Pyman, B. C. ; Clark, Graeme M. ( 1995)
    The Cochlear 22-channel cochlear implant has employed a succession of improved speech-processing strategies since its first use in an adult patient in Melbourne in 1982. 1 The first patients received the F0F2 coding strategy developed by the University of Melbourne, in the Wearable Speech Processor (WSP). The F0F2 coding scheme presented the implant user with three acoustic features of speech. These were 1) the amplitude of the waveform, presented as the amount of current charge, 2) fundamental frequency (F0) or voice pitch, presented as rate of biphasic pulsatile stimulation, and 3) the spectral range of the second formant frequency (F2), which was represented by varying the site of stimulation along the electrode array.
  • Item
    Thumbnail Image
    Implant designs for future coding strategies
    Patrick, J. F. ; Evans, A. R. ( 1995)
    This paper briefly describes the history of speech processing developments leading to the presently available Speak processing strategy. The similarities and differences of the Speak and Continuous Interleaved Sampling (CIS) strategies are then discussed and some recent key experimental observations are examined as a guide to potential future coding strategies. Key issues for future coding strategies and implant designs are the number of electrodes and stimulation rates in use. Consideration of these issues has led to development of a prototype implant to be used for advanced speech-processing research.
  • Item
    Thumbnail Image
    Evaluation of the Nucleus Spectra 22 Processor and New Speech Processing Strategy (SPEAK) in postlinguistically deafened adults
    Whitford, Lesley A. ; Seligman, Peter M. ; Everingham, Colleen E. ; Antognelli, Trisha ; Skok, Marisa C. ; Hollow, Rodney D. ; Plant, Kerrie L. ; Gerin, Elvira S. ; Staller, Steve J. ; McDermott, Hugh J. ; Gibson, William R. ; Clark, Graeme M. ( 1995)
    A new speech processing strategy (SPEAK) has been compared with the previous Multipeak (MPEAK) strategy in a study with 24 postlinguistically deafened adults. The results show that performance with the SPEAK coding strategy was significantly better for 58.3% of subjects on closed-set consonant identification, for 33.3% of subjects on closed-set vowel identification and open-set monosyllabic word recognition, and for 81.8% of subjects on open-set sentence recognition in quiet and in competing noise (+ 10 dB signal-to-noise ratio). By far the largest improvement observed was for sentence recognition in noise, with the mean score across subjects for the SPEAK strategy twice that obtained with MPEAK.
  • Item
    Thumbnail Image
    Comparison of the SPEAK (Spectral Maxima) and multipeak speech processing strategies and improved speech perception in background noise
    Clark, Graeme M. ; Whitford, L. ; Van Hoesel, R. ; McKay, C. M. ; McDermott, H. D. ; Seligman, P. ; Vandali, A. ; Pyman, B. C. ; Cowan, R. C. ( 1995)
    As more is known about speech processing for Cochlear Implant patients, results should continue to improve. It now appears possible that Cochlear Implant patients may, in some instances, reach performance levels that are better than those obtained by most severely deaf people who use hearing aids.
  • Item
    Thumbnail Image
    Multichannel cochlear implant speech processing: further variations of the spectral maxima sound processor strategy
    Vandali, A. E. ; Harrison, J. M. ; Huigen, J. M. ; Plant, K. ; Clark, Graeme M. ( 1995)
    The spectral maxima sound processor (SMSP) was first developed at the University of Melbourne in 1989. A full description of the SMSP has been given by McDermott et al.1 In short, the SMSP utilizes an ear-level microphone to measure acoustic sound pressure. A 16-channel band-pass filter bank is used to analyze the sound spectrum at discrete time intervals. Each of the 16 filters is assigned to one of the 16 intracochlear electrodes according to frequency. Within each time interval the six channels with the largest band-pass filter amplitudes are selected and used to stimulate six corresponding electrodes in quick succession. The current implementation of the SMSP2 differs from the original in that a digital signal processor is used in place of the analog filter bank and the microprocessor. The filter bank has been implemented with a discrete Fourier transform. Also, the input dynamic range has been improved by increasing the resolution of the analog-to-digital converter from 8 to 12 bits.
  • Item
    Thumbnail Image
    Investigations on a curved intracochlear array
    Donnelly, M. J. ; Cohen, L. T. ; Xu, J. ; Xu, S-A. ; Clark, Graeme M. ( 1995)
    The electrode array of a multiple-channel cochlear implant lies against the outer wall of the scala tympani. From this position electrical current spreads to excite residual neural elements, particularly spiral ganglion cells within the modiolus. It is not clear whether the spread of current from the outer wall is optimal for multiple-channel speech processing, but placement closer to the target nerves could result in lower thresholds. This could have benefits through the use of shorter pulse durations and extended battery life. Computer modeling studies and animal experiments have suggested that for localized current the optimal electrode position is adjacent to the modiolus. At the University of Melbourne it was felt that an electrode with a curve matching the internal cochlear spiral would remain close to the modiolus after insertion. A curved electrode was developed and an inserting tool was designed and produced (Treaba et al, this suppl, this section). Preliminary studies suggested that the electrode array did indeed remain close to the modiolus. Before further development of this type of electrode design, it was necessary to determine whether modifications to the surgical technique for its insertion were required. It was also important to ensure that the curved electrode fabricated for clinical trial would lie closer to the modiolus than to the outer wall of the scala tympani. This study was undertaken to examine these issues.